Rapid determination of biogenic amines in ossotide injections by microfluidic chip-mass spectrometry platform: Optimization of microfluidic chip derivatization using response surface methodology

被引:0
|
作者
Tang, Minmin [1 ,2 ]
Tan, Li [3 ]
Zhang, Mei [3 ]
Shi, Haiwei [3 ]
Zhao, Yaju [4 ]
Xu, Danke [1 ]
Zou, Jie [2 ]
机构
[1] Nanjing Univ, Sch Chem & Chem Engn, State Key Lab Analyt Chem Life Sci, Nanjing 210023, Peoples R China
[2] Jiangsu Prod Qual Testing & Inspect Inst, Nanjing 210007, Jiangsu, Peoples R China
[3] Jiangsu Inst Food & Drug Control, NMPA Key Lab Impur Profile Chem Drugs, Nanjing 210008, Peoples R China
[4] Zhejiang Gongshang Univ, Zhejiang Engn Res Inst Food & Drug Qual & Safety, Sch Management & Ebusiness, Hangzhou 310018, Peoples R China
基金
中国国家自然科学基金;
关键词
Microfluidic chip; MS; Biogenic amines; Ossotide injections; Response surface design; SPE; QUADRUPOLE-TIME;
D O I
10.1016/j.microc.2024.109989
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The microfluidic-chip mass spectrometry (MS) platform was developed for the rapid and automatic determination of 10 biogenic amines (BAs) in ossotide injections. The microfluidic chip was primarily consisted of a square unit for derivatization and a solid phase extraction (SPE) unit. The derivatization unit could achieve automatic mixing and reaction between sample and derivatization reagents, after which the targets were purified and enriched in SPE unit, further improving the sensitivity. To select the optimal derivatization conditions, four major parameters affecting derivatization in the microfluidic chip were optimized using Box-Behnken response surface design. On -chip derivatization unit enabled the shortest derivatization time by thorough solution mixing. There is no additional pretreatment required for the entire process. The developed method achieved satisfactory limits of detection (0.045-0.855 ng/mL) and limits of quantitation (0.156-3.11 ng/mL). The recoveries of the method ranged from 75.0 % to 106 % when coupled in -line with MS. This pretreatment chip -MS platform was successfully applied to BAs detection in the commercially available ossotide injections, demonstrating the prospects of this technique as a potential method for the rapid determination. The results of BAs in ossotide injections provide a basis for the formulation of the limit standard in pharmaceutical preparations.
引用
收藏
页数:8
相关论文
共 24 条
  • [1] Multi-channel microfluidic chip-mass spectrometry platform for cell analysis
    Jie, Mingsha
    Mao, Sifeng
    Li, Haifang
    Lin, Jin-Ming
    [J]. CHINESE CHEMICAL LETTERS, 2017, 28 (08) : 1625 - 1630
  • [2] Multi-channel microfluidic chip-mass spectrometry platform for cell analysis
    Mingsha Jie
    Sifeng Mao
    Haifang Li
    Jin-Ming Lin
    [J]. Chinese Chemical Letters, 2017, 28 (08) : 1625 - 1630
  • [3] An integrated microfluidic chip-mass spectrometry system for rapid antimicrobial resistance analysis of bacteria producing ?-lactamases
    Su, Zhaochen
    Hu, Wanting
    Ye, Lizhen
    Gao, Dan
    Lin, Jin-Ming
    [J]. CHINESE CHEMICAL LETTERS, 2023, 34 (05)
  • [4] An integrated microfluidic chip-mass spectrometry system for rapid antimicrobial resistance analysis of bacteria producing β-lactamases
    Zhaochen Su
    Wanting Hu
    Lizhen Ye
    Dan Gao
    Jin-Ming Lin
    [J]. Chinese Chemical Letters, 2023, 34 (05) : 354 - 357
  • [5] Online Monitoring of Lactate Efflux by Multi-Channel Microfluidic Chip-Mass Spectrometry for Rapid Drug Evaluation
    Liu, Wu
    Lin, Jin-Ming
    [J]. ACS SENSORS, 2016, 1 (04): : 344 - 347
  • [6] Multi-channel cell co-culture for drug development based on glass microfluidic chip-mass spectrometry coupled platform
    Wu, Jing
    Jie, Mingsha
    Dong, Xueling
    Qi, Hongbin
    Lin, Jin-Ming
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 : 80 - 86
  • [7] Rapid determination of cell mass and density using digitally controlled electric field in a microfluidic chip
    Zhao, Yuliang
    Lai, Hok Sum Sam
    Zhang, Guanglie
    Lee, Gwo-Bin
    Li, Wen Jung
    [J]. LAB ON A CHIP, 2014, 14 (22) : 4426 - 4434
  • [8] Solid phase extraction based microfluidic chip coupled with mass spectrometry for rapid determination of aflatoxins in peanut oil
    Chen, Jing
    Liu, Fei
    Li, Zhoumin
    Tan, Li
    Zhang, Mei
    Xu, Danke
    [J]. MICROCHEMICAL JOURNAL, 2021, 167
  • [9] Protein phosphorylation site determination using microfluidic chip interfaced with ETD ion trap and QTOF mass spectrometry
    Tang, N.
    Miller, C.
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (10) : S166 - S166
  • [10] Imitation of drug metabolism in cell co-culture microcapsule model using a microfluidic chip platform coupled to mass spectrometry
    Zheng, Yajing
    Wu, Zengnan
    Lin, Jin-Ming
    Lin, Ling
    [J]. CHINESE CHEMICAL LETTERS, 2020, 31 (02) : 451 - 454