Design of an X-ray irradiator with FLASH dose-rate capabilities for preclinical research

被引:0
|
作者
Ibanez, P. [1 ,2 ]
Espinosa-Rodriguez, A. [1 ,2 ]
Villa-Abaunza, A. [1 ,2 ]
Sanchez-Parcerisa, D. [1 ,2 ]
Diaz, N. [1 ,2 ]
Udias, J. M. [1 ,2 ]
机构
[1] Univ Complutense Madrid, Nucl Phys Grp, Dept Struct Matter Thermal Phys & Elect, Madrid, Spain
[2] Univ Complutense Madrid, IPARCOS, Madrid, Spain
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PO-1843
引用
收藏
页码:S1579 / S1580
页数:2
相关论文
共 50 条
  • [31] DOSE-RATE FIELD OF AN IRRADIATOR WITH USED FUEL ELEMENTS AS SOURCE OF GAMMA RADIATION
    DROZDOV, VE
    ZAKHAROV.IM
    DOBROVOL.SP
    JOURNAL OF NUCLEAR ENERGY PARTS A AND B-REACTOR SCIENCE AND TECHNOLOGY, 1966, 20 (1112): : 1011 - &
  • [32] A Novel Small Animal FLASH Irradiator (SAFI) Based On Distributed KV X-Ray Sources
    Tan, Y.
    Zhou, S.
    Chen, Q.
    Mazur, T.
    Darafsheh, A.
    Zhang, T.
    MEDICAL PHYSICS, 2022, 49 (06) : E520 - E521
  • [33] Plastic and Lead-Doped Scintillators for Ultrahigh Dose-Rate Irradiations Delivered with An X-Ray Tube
    Cecchi, D.
    Gigeure, C.
    Larose, F.
    Therriault-Proulx, F.
    Beaulieu, L.
    Bazalova-Carter, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [34] Real-time dosimetry of ultrahigh dose-rate x-ray beams using scintillation detectors
    Shaharuddin, Shahirah
    Hart, Alexander
    Cecchi, Daniel D.
    Bazalova-Carter, Magdalena
    Foley, Mark
    2021 IEEE SENSORS, 2021,
  • [35] Dose-rate controlled energy dispersive x-ray spectroscopic mapping of the metallic components in a biohybrid nanosystem
    Zhu, Yuanyuan
    Munro, Catherine J.
    Olszta, Matthew J.
    Edwards, Danny J.
    Braunschweig, Adam B.
    Knecht, Marc R.
    Browning, Nigel D.
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2016, 31 (08)
  • [36] THEORETICAL EVALUATION OF DOSE-RATE FOR A CO-60 SOURCE IN A POOL IRRADIATOR
    CURZIO, OA
    QUARANTA, HO
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1981, 32 (04): : 256 - 257
  • [37] Optimum aluminum absorber thickness of a small X-ray irradiator for equivalent dose determination
    D. G. Hong
    M. J. Kim
    T. Yawata
    T. Hashimoto
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 265 : 495 - 498
  • [38] Optimum aluminum absorber thickness of a small X-ray irradiator for equivalent dose determination
    Hong, DG
    Kim, MJ
    Yawata, T
    Hashimoto, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 265 (03) : 495 - 498
  • [39] X-RAY INDUCED MITOTIC RECOMBINATION IN DROSOPHILA-MELANOGASTER .1. ITS DEPENDENCE ON DOSE, DOSE-RATE AND SPECTRUM
    HAENDLE, J
    MOLECULAR AND GENERAL GENETICS, 1971, 113 (02): : 114 - &
  • [40] RADIATION OUTPUT AND DOSE PREDICTIONS FOR FLASH X-RAY SOURCES
    SANFORD, TWL
    HALBLEIB, JA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (06) : 1095 - 1100