Comparison of the effects of general and spinal anesthesia for cesarean delivery on maternal and fetal outcomes: A retrospective analysis of data

被引:1
|
作者
Ozden, Mesure Gul Nihan [1 ,3 ]
Koruk, Senem [1 ]
Collak, Zeynep [1 ]
Panik, Nur [2 ]
机构
[1] Istanbul Medeniyet Univ, Goztepe Prof Dr Suleyman Yalcin City Hosp, Dept Anesthesiol & Reanimat, Istanbul, Turkiye
[2] Bursa City Hosp, Dept Anesthesiol & Reanimat, Bursa, Turkiye
[3] Istanbul Medeniyet Univ, Goztepe Prof Dr Suleyman Yalcin Sehir Hastanesi, Anesteziyoloji ve Reanimasyon Anabilim Dali, Istanbul, Turkiye
关键词
Apgar score; cesarean section; general anesthesia; infant mortality; spinal anesthesia;
D O I
10.14744/nci.2023.25593
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: General or single-shut spinal anesthesia (SA) is applied for cesarean section and both methods of anesthesia have different effects on the mother and newborn. This retrospective study, in which 1-year data were analyzed, was aimed to examine the effects of general or SA on maternal and neonatal outcomes.METHODS: Anesthesia technique, mother's age, gestational age, number of pregnancies, previous cesarean delivery num-ber, maternal complications, and indications for cesarean delivery were analyzed in 883 cesarean deliveries. In addition, weight and Apgar scores of newborn and umbilical cord blood gas values were examined.RESULTS: Neonatal intensive care need was higher in the general anesthesia (GA) group, Apgar scores were higher in the SA group, but neonatal mortality was similar. The umbilical cord Ph and lactate were lower; PCO2 values were higher in the GA group. Neonatal weight, mother's age, gestational age, and Apgar scores were predictive for neonatal mortality, but anesthesia technique was not.CONCLUSION: While umbilical cord blood gas values were less affected and the need for neonatal intensive care was lower with SA, we believe that both anesthesia methods can be used safely for mother and neonatal in cesarean anesthesia con-sidering maternal and neonatal morbidity and mortality.
引用
收藏
页码:575 / 582
页数:8
相关论文
共 50 条
  • [21] Spinal Versus General Anesthesia for Cesarean Delivery in Pregnant Women With Moyamoya Disease: A Retrospective Observational Study
    Kim, Hee Jung
    Choi, Seung Ho
    Kwon, Hayan
    Park, Eun Kyung
    Kwon, Ja-Young
    Yang, Hyukjin
    Kim, Seung Hyun
    ANESTHESIA AND ANALGESIA, 2022, 135 (03): : 617 - 624
  • [22] Comparison of effects of rapid colloid loading before and after spinal anesthesia on maternal hemodynamics and neonatal outcomes in cesarean section
    Nishikawa K.
    Yokoyama N.
    Saito S.
    Goto F.
    Journal of Clinical Monitoring and Computing, 2007, 21 (02) : 125 - 129
  • [23] The effects of maternal position during induction of combined spinal-epidural anesthesia for cesarean delivery
    Yun, EM
    Marx, GF
    Santos, AC
    ANESTHESIA AND ANALGESIA, 1998, 87 (03): : 614 - 618
  • [24] Colloid Preload Versus Coload for Spinal Anesthesia for Cesarean Delivery: The Effects on Maternal Cardiac Output
    Teoh, Wendy H. L.
    Sia, Alex T. H.
    ANESTHESIA AND ANALGESIA, 2009, 108 (05): : 1592 - 1598
  • [25] Norepinephrine versus phenylephrine for managing maternal hypotension during cesarean delivery under spinal anesthesia: a meta-analysis of maternal and neonatal outcomes
    Song, Jianli
    Xu, Xi
    Li, Qiang
    Lu, Bin
    Yu, Xuan
    Mu, Guo
    SIGNA VITAE, 2024, 20 (04) : 1 - 14
  • [26] Maternal cardiovascular effects of spinal anesthesia for elective cesarean section
    Ueyama, H
    He, YL
    Tanigami, H
    Mashimo, T
    Yoshiya, I
    ANESTHESIOLOGY, 1998, 89 (3A) : U882 - U882
  • [27] INCREMENTAL SPINAL-ANESTHESIA FOR ELECTIVE CESAREAN-SECTION - MATERNAL AND FETAL HEMODYNAMIC-EFFECTS
    ROBSON, SC
    SAMSOON, G
    BOYS, RJ
    RODECK, C
    MORGAN, B
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (06) : 634 - 638
  • [28] Effect of Uterine Fundal Pressure on Maternal Intraocular Pressure in Cesarean Delivery: Comparison of Regional and General Anesthesia
    Kurtay, Aysun
    Ozayar, Esra
    Gulec, Handan
    Yildiz, Gokhan
    Turkyilmaz, Esra
    Yildiz, Zennure
    Horasanli, Eyup
    JOURNAL OF GLAUCOMA, 2017, 26 (08) : 708 - 711
  • [29] A Review of the Impact of Phenylephrine Administration on Maternal Hemodynamics and Maternal and Neonatal Outcomes in Women Undergoing Cesarean Delivery Under Spinal Anesthesia
    Habib, Ashraf S.
    ANESTHESIA AND ANALGESIA, 2012, 114 (02): : 377 - 390
  • [30] A comparison of maternal and neonatal outcomes with forceps delivery versus cesarean delivery
    Liu, Xiaohua
    Landon, Mark B.
    Cheng, Weiwei
    Chen, Yan
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2020, 33 (02): : 307 - 313