Optimized Camera-Based Patient Positioning in CT Impact on Radiation Exposure

被引:8
|
作者
Manava, Panagiota [1 ,2 ]
Galster, Marco [1 ]
Ammon, Josefin [3 ]
Singer, Julian [3 ]
Lell, Michael M. [1 ,2 ]
Rieger, Vera [1 ]
机构
[1] Paracelsus Med Univ, Dept Radiol & Nucl Med, Klinikum Nuemberg, Prof Ernst Nathan St 1, D-90419 Nurnberg, Germany
[2] Friedrich Alexander Univ Erlangen Nuremberg, Dept Radiol, Erlangen, Germany
[3] Paracelsus Med Univ, Inst Med Phys, Nurnberg, Germany
关键词
patient-centering; radiation dosage; diagnostic imaging; TUBE CURRENT MODULATION; COMPUTED-TOMOGRAPHY; IMAGE NOISE; VOLTAGE SELECTION; ORGAN; SYSTEMS; PHANTOM;
D O I
10.1097/RLI.0000000000000904
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveThe aim of this study was to evaluate whether a 3-dimensional (3D) camera can outperform highly trained technicians in precision of patient positioning and whether this transforms into a reduction in patient exposure.Materials and MethodsIn a single-center study, 3118 patients underwent computer tomography (CT) scans of the chest and/or abdomen on a latest generation single-source CT scanner supported with an automated patient positioning system by 3D camera. One thousand five hundred fifty-seven patients were positioned laser-guided by a highly trained radiographer (camera off) and 1561 patients with 3D camera (camera on) guidance. Radiation parameters such as effective dose, organ doses, CT dose index, and dose length product were analyzed and compared. Isocenter accuracy and table height were evaluated between the 2 groups.ResultsIsocenter positioning was significantly improved with the 3D camera (P < 0.001) as compared with visual laser-guided positioning. Absolute table height differed significantly (P < 0.001), being higher with camera positioning (165.6 +/- 16.2 mm) as compared with laser-guided positioning (170.0 +/- 20.4 mm). Radiation exposure decreased using the 3D camera as indicated by dose length product (321.1 +/- 266.6 mGy center dot cm; camera off: 342.0 +/- 280.7 mGy center dot cm; P = 0.033), effective dose (3.3 +/- 2.7 mSv; camera off: 3.5 +/- 2.9; P = 0.053), and CT dose index (6.4 +/- 4.3 mGy; camera off: 6.8 +/- 4.6 mGy; P = 0.011). Exposure of radiation-sensitive organs such as colon (P = 0.015) and red bone marrow (P = 0.049) were also lower using the camera.ConclusionsThe introduction of a 3D camera improves patient positioning in the isocenter of the scanner, which results in a lower and also better balanced dose reduction for the patients.
引用
收藏
页码:126 / 130
页数:5
相关论文
共 50 条
  • [1] CaPSuLe: A Camera-based Positioning System Using Learning
    Moon, Yongshik
    Noh, Soonhyun
    Park, Daedong
    Luo, Chen
    Shrivastava, Anshumali
    Hong, Seongsoo
    Palem, Krishna
    2016 29TH IEEE INTERNATIONAL SYSTEM-ON-CHIP CONFERENCE (SOCC), 2016, : 235 - 240
  • [2] Quantifying Feature Association Error in Camera-based Positioning
    Zhu, Chen
    Joerger, Mathieu
    Meurer, Michael
    2020 IEEE/ION POSITION, LOCATION AND NAVIGATION SYMPOSIUM (PLANS), 2020, : 967 - 972
  • [3] Optical Camera Communication for Active Marker Identification in Camera-based Positioning Systems
    Gorse, Lorenz
    Loeffler, Christoffer
    Mutschler, Christopher
    Philippsen, Michael
    2018 15TH WORKSHOP ON POSITIONING, NAVIGATION AND COMMUNICATIONS (WPNC), 2018,
  • [4] Occupational Radiation exposure from PET/CT during patient positioning
    Siyanbola, R.
    Coelho, M.
    Costa, P. Fragoso
    Moraitis, A.
    Herrmann, K.
    Hautzel, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S150 - S150
  • [5] Research on Optimization of Camera-based Visible Light Positioning System
    Liu Xiangyu
    Liu Baorui
    Song Song
    Guo Lei
    JOURNAL OF ELECTRONICS & INFORMATION TECHNOLOGY, 2022, 44 (12) : 4246 - 4255
  • [6] Influence of tube and patient positioning in thoracoabdominal CT examinations on radiation exposure-towards a better patient positioning
    Valentin, Birte
    Kamp, Benedikt
    Henke, Jan
    Ljimani, Alexandra
    Appel, Elisabeth
    Antoch, Gerald
    Steuwe, Andrea
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (03)
  • [7] Camera-based localization microscopy optimized with calibrated structured illumination
    Schmidt, Martin
    Hundahl, Adam C.
    Flyvbjerg, Henrik
    Marie, Rodolphe
    Mortensen, Kim I.
    COMMUNICATIONS PHYSICS, 2021, 4 (01)
  • [8] Camera-based localization microscopy optimized with calibrated structured illumination
    Martin Schmidt
    Adam C. Hundahl
    Henrik Flyvbjerg
    Rodolphe Marie
    Kim I. Mortensen
    Communications Physics, 4
  • [9] Impact of CT fusion on camera-based PET (CBPET) for clinical oncology applications.
    Brown, SD
    Wong, TZ
    Turkington, T
    Coleman, RE
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 35P - 36P
  • [10] Mobile Camera-Based Positioning Method by Applying Landmark Corner Extraction
    Lee, Yoo Jin
    Yoon, Wansang
    Rhee, Sooahm
    KOREAN JOURNAL OF REMOTE SENSING, 2023, 39 (06) : 1309 - 1320