Low-frequency ultrasound for pulmonary hypertension therapy

被引:1
|
作者
Ostasevicius, Vytautas [1 ]
Jurenas, Vytautas [1 ]
Venslauskas, Mantas [1 ]
Kizauskiene, Laura [2 ]
Zigmantaite, Vilma [3 ,4 ]
Stankevicius, Edgaras [5 ]
Bubulis, Algimantas [1 ]
Vezys, Joris [6 ]
Mikuckyte, Sandra [1 ]
机构
[1] Kaunas Univ Technol, Inst Mechatron, Studentu St 56, LT-51424 Kaunas, Lithuania
[2] Kaunas Univ Technol, Dept Comp Sci, Studentu St 50, LT-51368 Kaunas, Lithuania
[3] Univ Hlth Sci, Biol Res Ctr Lithuanian, Tilzes St 18, LT-47181 Kaunas, Lithuania
[4] Lithuanian Univ Hlth Sci, Cardiol Dept, Lab Membrane Biophys, Sukileliu St 15, LT-50103 Kaunas, Lithuania
[5] Lithuanian Univ Hlth Sci, Inst Physiol & Pharmacol, A Mickevicius St 9, LT-44307 Kaunas, Lithuania
[6] Kaunas Univ Technol, Dept Mech Engn, Studentu St 56, LT-51424 Kaunas, Lithuania
关键词
INTENSITY ULTRASOUND; PRESSURE;
D O I
10.1186/s12931-024-02713-5
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
BackgroundCurrently, there are no reliable clinical tools that allow non-invasive therapeutic support for patients with pulmonary arterial hypertension. This study aims to propose a low-frequency ultrasound device for pulmonary hypertension therapy and to demonstrate its potential.MethodsA novel low-frequency ultrasound transducer has been developed. Due to its structural properties, it is excited by higher vibrational modes, which generate a signal capable of deeply penetrating biological tissues. A methodology for the artificial induction of pulmonary hypertension in sheep and for the assessment of lung physiological parameters such as blood oxygen concentration, pulse rate, and pulmonary blood pressure has been proposed.ResultsThe results showed that exposure of the lungs to low-frequency ultrasound changed physiological parameters such as blood oxygen concentration, pulse rate and blood pressure. These parameters are most closely related to indicators of pulmonary hypertension (PH). The ultrasound exposure increased blood oxygen concentration over a 7-min period, while pulse rate and pulmonary blood pressure decreased over the same period. In anaesthetised sheep exposed to low-frequency ultrasound, a 10% increase in SpO2, a 10% decrease in pulse rate and an approximate 13% decrease in blood pressure were observed within 7 min.ConclusionsThe research findings demonstrate the therapeutic efficiency of low-frequency ultrasound on hypertensive lungs, while also revealing insights into the physiological aspects of gas exchange within the pulmonary system.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] ANTIBIOTIC-THERAPY OF BRONCHIAL PYOINFLAMMATION USING ENDOBRONCHIAL LOW-FREQUENCY ULTRASOUND
    OVCHARENKO, SI
    LOGINOV, LY
    ZAVODNOV, VY
    [J]. KLINICHESKAYA MEDITSINA, 1991, 69 (09): : 29 - 31
  • [22] Low-frequency ultrasound treatment of chronic venous leg ulcers in an outpatient therapy
    Peschen, M
    Weichenthal, M
    Schopf, E
    Vanscheidt, W
    [J]. ACTA DERMATO-VENEREOLOGICA, 1997, 77 (04) : 311 - 314
  • [23] Acoustic parameter measurement for low-frequency ultrasound
    Wang Baoqiang
    Deng Changjian
    Li Yiding
    Sun Yuansheng
    [J]. PROCEEDINGS OF THE FIRST INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 - 3, 2006, : 1338 - 1343
  • [24] Transcutaneous immunisation assisted by low-frequency ultrasound
    Dahlan, Afendi
    Alpar, H. Oya
    Stickings, Paul
    Sesardic, Dorothea
    Murdan, Sudaxshina
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2009, 368 (1-2) : 123 - 128
  • [25] Low-Frequency Ultrasound in Medicine: An In Vivo Evaluation
    Fiorillo, Antonino S.
    Grimaldi, Domenico
    Paolino, Donatella
    Pullano, Salvatore A.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (06) : 1658 - 1663
  • [26] THE ULTRASOUND LOW-FREQUENCY CAVITATION IN PURULENT SURGERY
    ISMAILOV, AA
    KULIEV, RA
    [J]. VESTNIK KHIRURGII IMENI I I GREKOVA, 1985, 134 (02): : 146 - 149
  • [27] EFFECT OF LOW-FREQUENCY ULTRASOUND ON PYOGENIC MICROFLORA
    IVANOV, VV
    [J]. KHIRURGIYA, 1982, (04): : 30 - 33
  • [28] Low-frequency ultrasound as a transcutaneous immunization adjuvant
    Tezel, A
    Paliwal, S
    Shen, ZC
    Mitragotri, S
    [J]. VACCINE, 2005, 23 (29) : 3800 - 3807
  • [29] The effects of low-frequency ultrasound on Staphylococcus epidermidis
    Singer, AJ
    Coby, CT
    Singer, AH
    Thode, HC
    Tortora, GT
    [J]. CURRENT MICROBIOLOGY, 1999, 38 (03) : 194 - 196
  • [30] The Effects of Low-Frequency Ultrasound on Staphylococcus epidermidis
    Adam J. Singer
    Christopher T. Coby
    Ayellet H. Singer
    Henry C. Thode Jr.
    George T. Tortora
    [J]. Current Microbiology, 1999, 38 : 194 - 196