Effect of different span lengths with different total occlusal convergences on the accuracy of intraoral scanners

被引:5
|
作者
Yehia, Ashraf [1 ]
Abo El Fadl, Ahmad [1 ]
El Sergany, Omar [2 ]
Ebeid, Kamal [1 ,3 ]
机构
[1] Ain Shams Univ, Fac Dent, Dept Fixed Prosthodont, Cairo, Egypt
[2] British Univ Egypt, Fac Dent, Dept Fixed Prosthodont, Cairo, Egypt
[3] Org African Unity St, Heliopolis, Cairo, Egypt
关键词
digital dentistry; fixed prosthodontics; intraoral scanners; span length; total occlusal convergence; DENTAL IMPRESSIONS; ARCH IMPRESSIONS; DIGITAL METHODS; PRECISION; TRUENESS;
D O I
10.1111/jopr.13686
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim was to assess the effect of span lengths and total occlusal convergence (TOC) on the accuracy of intraoral scanners. Materials and methods: Two typodont acrylic teeth models were prepared to receive fixed dental prostheses with three different span lengths. Span 1: between maxillary canines; span 2: between maxillary second premolars; and span 3: between maxillary second molars. In the first model, prepared teeth had a TOC of 12 degrees, whereas, in the second model, teeth had a TOC of 20 degrees. Each model was scanned 10 times using 4 different intraoral scanners (Omnicam, Primescan, Trios 4, and Medit i500). The STL files from the scans were compared to the reference models (trueness) and within each test group (precision) using a 3D comparison software. Data were then statistically analyzed. Results: Regarding trueness, no significant differences were found among Primescan (32.58 +/- 13.08), Trios 4 (32.33 +/- 12.19), and Medit i500 (32.26 +/- 9.57). However, all showed significantly better trueness than Omnicam (35.70 +/- 8.35) (p < 0.001). The highest values were found in scans between the second molars (47.42 +/- 3.94), followed by scans between second premolars (28.42 +/- 3.78), and the highest trueness was found in scans between the canines (23.80 +/- 3.85). For TOC, 12 degrees had a significantly higher value than 20 degrees (p < 0.001). Regarding precision, the highest values were found with Omnicam (29.84 +/- 3.89), followed by Medit i500 (28.04 +/- 2.94), then Trios 4 (25.64 +/- 3.11), and Primescan (24.69 +/- 5.25). The highest values and least precision were found in scans between the second molars (28.97 +/- 5.27) and scans between second premolars (27.59 +/- 3.97), whereas the highest precision was found in scans between the canines (24.60 +/- 2.04). For TOC, 12 degrees had significantly higher values than 20 degrees (p < 0.001). Conclusions: Intraoral scans are directly affected by scanner type, TOC, and scan spans. All tested scanners showed clinically acceptable results even for long-span restorations.
引用
收藏
页码:252 / 258
页数:7
相关论文
共 50 条
  • [21] Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant-supported full arch fixed prosthesis
    Ashraf, Yasmine
    Abo El Fadl, Ahmad
    Hamdy, Amina
    Ebeid, Kamal
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (08) : 1257 - 1263
  • [22] Digital plaque monitoring: An evaluation of different intraoral scanners
    Jung, Katja
    Giese-Kraft, Katja
    Schlenz, Maximiliane Amelie
    Woestmann, Bernd
    Ganss, Carolina
    [J]. JOURNAL OF DENTISTRY, 2024, 145
  • [23] Influence of interdental spaces and the palate on the accuracy of maxillary scans acquired using different intraoral scanners
    Akl, Mohammed A.
    Daifallah, Khaled
    Perez-Barquero, Jorge Alonso
    Barmak, Abdul B.
    Wee, Alvin G.
    Revilla-Leon, Marta
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, : 125 - 134
  • [24] Understanding the effect of scan spans on the accuracy of intraoral and desktop scanners
    Chen, Yuming
    Zhai, Zhihao
    Watanabe, Shota
    Nakano, Tamaki
    Ishigaki, Shoichi
    [J]. JOURNAL OF DENTISTRY, 2022, 124
  • [25] Effect of pulp chamber depth on the accuracy of endocrown scans made with different intraoral scanners versus an industrial scanner: An in vitro study
    Gurpinar, Bahar
    Tak, Onjen
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 430 - 437
  • [26] Influence of Different Material Substrates on the Accuracy of Three Intraoral Scanners: A Single-Blinded In Vitro Study
    Michelinakis, George
    Apostolakis, Dimitrios
    Tsagarakis, Andreas
    Lampropoulos, Panagiotis
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (01) : 82 - 93
  • [27] Use of Intraoral Scanners for Full Dental Arches: Could Different Strategies or Overlapping Software Affect Accuracy?
    Stefanelli, Luigi Vito
    Franchina, Alessio
    Pranno, Andrea
    Pellegrino, Gerardo
    Ferri, Agnese
    Pranno, Nicola
    Di Carlo, Stefano
    De Angelis, Francesca
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (19)
  • [28] In Vitro Comparison of the Accuracy of Conventional Impression and Four Intraoral Scanners in Four Different Implant Impression Scenarios
    Alpkilic, Dilara Seyma
    Deger, Sabire Isler
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 39 - 48
  • [29] Effect of different intraoral scanners and post-space depths on the trueness of digital impressions
    Emam, Marwa
    Ghanem, Lomaya
    Sadek, Hoda M. Abdel
    [J]. DENTAL AND MEDICAL PROBLEMS, 2024, 61 (04) : 577 - 584
  • [30] Comparative Analysis of Four Different Intraoral Scanners: An In Vitro Study
    Ciocan, Lucian Toma
    Vasilescu, Vlad Gabriel
    Rauta, Sabina-Ana
    Pantea, Mihaela
    Pituru, Silviu-Mirel
    Imre, Marina
    [J]. DIAGNOSTICS, 2024, 14 (13)