Dental implant fracture is closely connected to the stress buildup surrounding the implant system during static loading. In areas where the cross-section of the implant rapidly changes or where the geometry of the implant system has discontinuities, stress concentrations arise. Therefore, the implant's design is crucial in preventing early failure of the implant system, including fracture, screw loosening, and increased leakage, in addition to reducing stresses at the implant-abutment interface. In the current work, three-dimensional (3D) models of mechanically connected Ti6-Al-4V implant systems in various dimensions were constructed. Finite element analysis (FEA) was used to conduct a stress study of the created implants under actual acting force static loading conditions in accordance with ISO 14801. In the created models, design elements including implant screw type, thickness, and taper angle of abutment were modified in order to increase the longevity of the implants. The results show that the equivalent stress level was dramatically reduced from 596.22 MPa to 212.72 MPa in the implant model, which exhibits a more homogeneous stress pattern under static loading conditions. By increasing the implant wall thickness from 0.15 mm to 0.40 mm in the region adjacent to the abutment, the stress levels, especially at the internal screw, were significantly reduced. Also, the design modification in Model B, establishing contact between the abutment and the upper part of the conical surface of the implant, resulted in a decrease in stress in the internal screw. Thus, enhanced homogeneity in stress distribution not only improves the harmony between the implant and surrounding tissues, thus increasing patient comfort and reducing the risk of complications, but also holds promise for the development of new implants capable of withstanding the forces encountered in the oral environment due to the relatively smoother stress transmission observed in this model.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Comparative study of the influence of dental implant design on the stress and strain distribution using the finite element method
    Castilla, R.
    Forero, L.
    Gonzalez-Estrada, O. A.
    INTERNATIONAL SCIENCE WEEK: CHALLENGES OF SCIENCE IN THE 21ST CENTURY, 2019, 1159
  • [2] Comparative Study of the Influence of Dental Implant Design on the Stress and Strain Distribution using the Finite Element Method
    Sahai, Neha Srivastava
    Yadav, Divya
    Madhav, Srishti
    Kumar, Naveen
    Dubey, Anuradha
    Qadeer, Nazia
    Makkad, Ramanpal Singh
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2776 - S2778
  • [3] Evaluation of the Influence of Bone Resorption on Dental Implant Systems Using Taguchi Method and Finite Element Analysis
    Liu, Chien-Wei
    Chuang, Kai-Jen
    Chen, Chien-Tsu
    Lin, Kuan-Chou
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2021, 11 (02) : 276 - 281
  • [4] ANALYSIS OF A DENTAL IMPLANT USING FINITE ELEMENT METHOD
    Vlasceanu, Daniel
    Petrescu, Ioana
    Comaneanu, Raluca Monica
    Tarcolea, Mihai
    Cotrut, Mihai Cosmin
    ANNALS OF DAAAM FOR 2009 & PROCEEDINGS OF THE 20TH INTERNATIONAL DAAAM SYMPOSIUM, 2009, 20 : 1277 - 1278
  • [5] Fatigue behaviour of dental implant using finite element method
    Kumar Srivastav C.
    Kapoor R.
    Khan D.
    Materials Today: Proceedings, 2022, 56 : 1143 - 1150
  • [6] A study on stress analysis of 3 kinds of dental implant in the mandible by using finite element method
    Kim, YS
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1316 - 1316
  • [7] Biomechanical Simulation of a Dental Implant using Finite Element Method Analysis
    Costa, D. C.
    Belinha, J.
    Natal Jorge, R. M.
    2019 6TH IEEE PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2019,
  • [8] Finite element analysis of the dental implant using a topology optimization method
    Chang, Chih-Ling
    Chen, Chen-Sheng
    Huang, Chang-Hung
    Hsu, Ming-Lun
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (07) : 999 - 1008
  • [9] Finite Element Analysis of Stress in Dental Bridge with Implant
    Huang, Wan-Ting
    Cheng, Han-Yi
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2020, 10 (06) : 743 - 748
  • [10] Stress Analysis of Hybrid Implant Using Finite Element Method
    Kwon, Young-Doo
    Jang, Suck-Ho
    Park, Sang-Hyun
    Lee, Sang-Won
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2008, 32 (03) : 290 - 296