Comparison of Transcutaneous and Total Serum Bilirubin Measurements at Five Different Sites in Newborns before and after Phototherapy

被引:0
|
作者
Eken, Seda [1 ]
Ilhan, Ozkan [2 ,3 ]
Hakan, Nilay [2 ]
机构
[1] Mugla Sitki Kocman Univ, Sch Med, Dept Pediat, Mugla, Turkiye
[2] Mugla Sitki Kocman Univ, Dept Pediat, Div Neonatol, Sch Med, Mugla, Turkiye
[3] Mugla Sitki Kocman Univ, Sch Med, Pediat, TR-48000 Mugla, Mugla, Turkiye
来源
KLINISCHE PADIATRIE | 2024年 / 236卷 / 01期
关键词
transcutaneous; bilirubin; jaundice; hyperbilirubinemia; newborn; phototherapy; PRETERM; SKIN; HYPERBILIRUBINEMIA; ACCURACY;
D O I
10.1055/a-2135-3367
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective This study aims to examine the accuracy of transcutaneous bilirubin (TcB) in estimating the total serum bilirubin (TSB) level at five different sites before and immediately after phototherapy. Methods This study prospectively enrolled infants with a gestational age of 34 to 41(6/7) weeks who were clinically diagnosed with neonatal jaundice and required phototherapy within 28 days after birth. TcB levels were measured on the uncovered four areas (forehead, mid-sternum, abdomen, and interscapular site) and covered hipbone by using the Drager JM-103 Jaundice Meter before phototherapy and at 0 min after discontinuing phototherapy. Correlation and agreement between TcB and TSB levels were assessed before and after phototherapy. Results We included 108 infants with a mean gestational age of 37.6 +/- 1.5 weeks and birth weight of 3108 +/- 548 g. A strong significant correlation was found between TSB and TcB measurements at all five sites before phototherapy with the strongest correlation at the interscapular site ( r = 0.768, p = 0.001). The correlation was weakened between TSB and TcB at all five sites after phototherapy; however, the strongest correlation was at the covered hipbone (r = 0.619, p = 0.001). TcB measurements at all five sites tended to underestimate TSB levels before and after phototherapy. The difference ( TcB - TSB) tended to increase with increasing TSB levels. Conclusions TcB levels were most accurately measured at the interscapular site and covered hipbone before and immediately after phototherapy, respectively.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 50 条
  • [41] Comparison of Diagnostic Accuracy of Different Sites for Transcutaneous Bilirubin Measurement in Early Preterm Infants
    Agrawal, Garima
    Garg, Kapil
    Sitaraman, Sadasivan
    Sarna, Anurag
    [J]. INDIAN JOURNAL OF PEDIATRICS, 2019, 86 (01): : 32 - 37
  • [42] A comparison of transcutaneous and total serum bilirubin in newborn Hispanic infants at 35 or more weeks of gestation
    Kolman, Karyn B.
    Mathieson, Kathleen M.
    Frias, Carlos
    [J]. JOURNAL OF THE AMERICAN BOARD OF FAMILY MEDICINE, 2007, 20 (03) : 266 - 271
  • [43] A Comparison Between Transcutaneous Bilirubin and Total Serum Bilirubin Levels for the Management of Jaundice in Preterm Neonates by Bland-Altman Plot
    Panda, Santosh K.
    Gaurav, Abhinav
    Das, Palash
    Swain, Natabar
    Rath, Soumini
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (10)
  • [44] Comparison of the Predictive Accuracy of Stool Color for Triage of Infants for Phototherapy (STrIP) Score With Transcutaneous Bilirubinometer in Predicting Serum Bilirubin in Neonates
    Sushma Krishnegowda
    Basil John Thomas
    Deepti Thandaveshwara
    Srinivasa Murthy Doreswamy
    [J]. Indian Pediatrics, 2021, 58 : 936 - 939
  • [45] Comparison of the Predictive Accuracy of Stool Color for Triage of Infants for Phototherapy (STrIP) Score With Transcutaneous Bilirubinometer in Predicting Serum Bilirubin in Neonates
    Krishnegowda, Sushma
    Thomas, Basil John
    Thandaveshwara, Deepti
    Doreswamy, Srinivasa Murthy
    [J]. INDIAN PEDIATRICS, 2021, 58 (10) : 936 - 939
  • [46] Comparison of a new transcutaneous bilirubinometer (Bilimed®) with serum bilirubin measurements in preterm and full-term infants
    Karen, Tanja
    Bucher, Hans Ulrich
    Fauchere, Jean-Claude
    [J]. BMC PEDIATRICS, 2009, 9
  • [47] Comparison of a new transcutaneous bilirubinometer (Bilimed®) with serum bilirubin measurements in preterm and full-term infants
    Tanja Karen
    Hans Ulrich Bucher
    Jean-Claude Fauchère
    [J]. BMC Pediatrics, 9
  • [48] Phenobarbital and Phototherapy Combination Enhances Decline of Total Serum Bilirubin and May Decrease the Need for Blood Exchange Transfusion in Newborns with Isoimmune Hemolytic Disease
    Kaabneh, Mahmoud A. F.
    Salama, Ghassan S. A.
    Shakkoury, Ayoub G. A.
    Al-Abdallah, Ibrahim M. H.
    Alshamari, Afrah
    Halaseh, Ruba A. A.
    [J]. CLINICAL MEDICINE INSIGHTS-PEDIATRICS, 2015, 9 : 67 - 72
  • [49] Comparison of skin sites for estimating serum total bilirubin in in-patients and out-patients: Chest is superior to brow
    Poland R.L.
    Hartenberger C.
    McHenry H.
    Hsi A.
    [J]. Journal of Perinatology, 2004, 24 (9) : 541 - 543
  • [50] Improved transcutaneous bilirubinometry: Comparison of SpectRx BiliCheck and Minolta Jaundice Meter JM-102 for estimating total serum bilirubin in a normal newborn population
    Robertson A.
    Kazmierczak S.
    Vos P.
    [J]. Journal of Perinatology, 2002, 22 (1) : 12 - 14