Fire-resistant design of stainless steel-concrete composite beam considering slip of stud connector

被引:2
|
作者
Wu, Mingze [1 ]
Fan, Shenggang [1 ]
Han, Yunlong [3 ]
Liang, Dun [1 ]
Xu, Qingfeng [2 ]
机构
[1] Southeast Univ, Sch Civil Engn, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Jiulonghu Campus, Nanjing 211189, Peoples R China
[2] SRIBS, Shanghai Key Lab Engn Struct Safety, Shanghai 200032, Peoples R China
[3] Southeast Univ, Architects & Engineers Co Ltd, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Stainless steel-concrete composite beam; Stainless steel stud connector; Fire resistance; Critical temperature; Fire-resistant design approach; SHEAR CONNECTORS; BEHAVIOR; SLABS;
D O I
10.1016/j.tws.2023.110713
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Stainless steel-concrete (SSC) composite beams have gained attention in structural engineering in recent years. However, there is currently no fire-resistant design approach proposed specifically for SSC composite beams. The current fire-resistant design approach for composite beam is based on the material behavior of carbon steel, which may not accurately reflect the behavior of SSC composite beams due to the significant differences in material properties. In particular, the nonlinear constitutive characteristic and greater coefficient of expansion of stainless steel compared to carbon steel can impact the fire resistance of SSC composite beams. The shear behavior of connectors is also crucial in composite beams, with the shear behavior of connectors being of particular importance. Towards clarifying the shear behavior of the stainless steel stud connectors, this paper conducted push-out tests and finite element analyses. The load-slip curves of the S30408 stainless steel stud connectors with different diameters (13 mm, 16 mm, 19 mm, 22 mm) at different temperatures were obtained. Subsequently, comprehensive parameter analyses of the fire resistance of the S30408 SSC composite beam based on the load-slip curves of the stud connectors were conducted. Based on these analysis results, the essential modification of the formula of ultimate bearing capacity at elevated temperature of the Chinese national standard GB 51249-2017 was conducted. Moreover, a modified fire-resistant design approach was proposed to predict the critical temperature of the S30408 SSC composite beam under the ISO-834 standard fire, and the approach was assessed by existing test results.
引用
下载
收藏
页数:19
相关论文
共 50 条
  • [21] V-shaped shear connector for composite steel-concrete beam
    Bezerra, Luciano M.
    Cavalcante, Otavio O.
    Chater, Latif
    Bonilla, Jorge
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 150 : 162 - 174
  • [22] Slip analysis of prestressed steel-concrete continuous composite beam
    Sun J.
    Yue Z.
    He Y.
    Ibrahim Shah Y.
    Journal of King Saud University - Engineering Sciences, 2024, 36 (08) : 535 - 542
  • [23] Mechanical Analysis of the Influence of Rubber-Sleeved Stud Connector on the Steel-Concrete Composite Girder
    Su Q.
    Su H.
    Wu F.
    Tongji Daxue Xuebao/Journal of Tongji University, 2021, 49 (08): : 1079 - 1087
  • [24] Behaviour and design of stainless steel-concrete composite beams
    Zhou, Yifan
    Uy, Brian
    Wang, Jia
    Li, Dongxu
    Huang, Zhichao
    Liu, Xinpei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 185
  • [25] Effects of shrinkage in composite steel-concrete beam subjected to fire
    Rahal, Nacer
    Souici, Abdelaziz
    Beghdad, Houda
    Tehami, Mohamed
    Djaffari, Dris
    Sadoun, Mohamed
    Benmahdi, Khaled
    STEEL AND COMPOSITE STRUCTURES, 2024, 50 (04): : 375 - 382
  • [26] Flexural Behavior of Steel-Concrete Composite Beams Considering Interlayer Slip
    Zhang, Qinghua
    Jia, Donglin
    Bao, Yi
    Dong, Sheng
    Cheng, Zhenyu
    Bu, Yizhi
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (09)
  • [27] Effect of Shear Connector Layout on the Behavior of Steel-Concrete Composite Beams with Interface Slip
    Zeng, Xinggui
    Jiang, Shao-Fei
    Zhou, Donghua
    APPLIED SCIENCES-BASEL, 2019, 9 (01):
  • [28] Fire-resistant design of eccentrically compressed stainless steel columns with constraints
    Liu, Meijing
    Fan, Shenggang
    Sun, Wenjun
    Ding, Runmin
    Zhu, Ting
    FIRE SAFETY JOURNAL, 2018, 100 : 1 - 19
  • [29] Experimental study on the shear behavior of a bolt connector in a steel-concrete composite beam
    Yang Y.
    Zhang S.
    Chen X.
    Feng S.
    Yang S.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2024, 45 (06): : 1076 - 1084
  • [30] Static test on the new type shear connector composite steel-concrete beam
    College of Civil Engineering, Nanjing University of Technology, Nanjing 210009, China
    Harbin Gongye Daxue Xuebao, 2007, SUPPL. 2 (283-286): : 283 - 286