Fire-resistant design of stainless steel-concrete composite beam considering slip of stud connector

被引:2
|
作者
Wu, Mingze [1 ]
Fan, Shenggang [1 ]
Han, Yunlong [3 ]
Liang, Dun [1 ]
Xu, Qingfeng [2 ]
机构
[1] Southeast Univ, Sch Civil Engn, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Jiulonghu Campus, Nanjing 211189, Peoples R China
[2] SRIBS, Shanghai Key Lab Engn Struct Safety, Shanghai 200032, Peoples R China
[3] Southeast Univ, Architects & Engineers Co Ltd, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Stainless steel-concrete composite beam; Stainless steel stud connector; Fire resistance; Critical temperature; Fire-resistant design approach; SHEAR CONNECTORS; BEHAVIOR; SLABS;
D O I
10.1016/j.tws.2023.110713
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Stainless steel-concrete (SSC) composite beams have gained attention in structural engineering in recent years. However, there is currently no fire-resistant design approach proposed specifically for SSC composite beams. The current fire-resistant design approach for composite beam is based on the material behavior of carbon steel, which may not accurately reflect the behavior of SSC composite beams due to the significant differences in material properties. In particular, the nonlinear constitutive characteristic and greater coefficient of expansion of stainless steel compared to carbon steel can impact the fire resistance of SSC composite beams. The shear behavior of connectors is also crucial in composite beams, with the shear behavior of connectors being of particular importance. Towards clarifying the shear behavior of the stainless steel stud connectors, this paper conducted push-out tests and finite element analyses. The load-slip curves of the S30408 stainless steel stud connectors with different diameters (13 mm, 16 mm, 19 mm, 22 mm) at different temperatures were obtained. Subsequently, comprehensive parameter analyses of the fire resistance of the S30408 SSC composite beam based on the load-slip curves of the stud connectors were conducted. Based on these analysis results, the essential modification of the formula of ultimate bearing capacity at elevated temperature of the Chinese national standard GB 51249-2017 was conducted. Moreover, a modified fire-resistant design approach was proposed to predict the critical temperature of the S30408 SSC composite beam under the ISO-834 standard fire, and the approach was assessed by existing test results.
引用
下载
收藏
页数:19
相关论文
共 50 条
  • [1] A load-slip model for stud connector in steel-concrete composite structures
    Song, Li
    Fang, Siqi
    Cui, Chenxing
    Yu, Zhiwu
    Wang, Zhichao
    ADVANCES IN STRUCTURAL ENGINEERING, 2023, 26 (03) : 489 - 504
  • [2] Analysis Of Stud Connector of Steel-Concrete Composite Structure
    Liu Xiaoyu
    Yang Jinhui
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 328 - 332
  • [3] Fire analysis of steel-concrete composite beam with interlayer slip
    Hozjan, Tomaz
    Saje, Miran
    Srpcic, Stanislav
    Planinc, Igor
    COMPUTERS & STRUCTURES, 2011, 89 (1-2) : 189 - 200
  • [4] Random shear resistance of a headed-stud connector in composite steel-concrete beam
    Domański, Tomasz
    Maślak, Mariusz
    Archives of Civil Engineering, 2024, 70 (04) : 425 - 439
  • [5] Experiments on fire-resistance performance of fire-resistant steel-concrete composite beams
    Jiang X.
    Tong G.-S.
    Zhang L.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2016, 50 (08): : 1463 - 1470
  • [6] Study on uplift performance of stud connector in steel-concrete composite structures
    Ju, Xiaochen
    Zeng, Zhibin
    STEEL AND COMPOSITE STRUCTURES, 2015, 18 (05): : 1279 - 1290
  • [7] Fire-resistance performance of simply supported fire-resistant steel-concrete composite beams
    Jiang X.
    Tong G.
    Zhang L.
    Tong, Genshu (tonggs@zju.edu.cn), 1600, Harbin Institute of Technology (49): : 68 - 74
  • [8] The slip and deformation of steel-concrete composite beam
    Jiang, Li-Zhong
    Yu, Zhi-Wu
    ADVANCES IN STRUCTURAL ENGINEERING:THEORY AND APPLICATIONS VOLS 1 AND 2, 2006, : 1245 - 1249
  • [9] The slip of steel-concrete composite continuous beam
    Jiang, LZ
    Yu, ZW
    Li, J
    ICACS 2003: INTERNATIONAL CONFERENCE ON ADVANCES IN CONCRETE AND STRUCTURES, VOL 1 AND 2, 2003, 32 : 1396 - 1403
  • [10] Numerical analysis on cracking behavior of concrete slab due to corrosion expansion of stud connector in steel-concrete composite beam
    Xiao, Lin
    Wei, Huan-Bo
    Wei, Xing
    Kang, Zhi-Rui
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2024, 54 (07): : 1958 - 1965