Standardization of 109Cd Using CIEMAT/NIST Method and Internal Conversion Electron Counting

被引:0
|
作者
Kulkarni, D. B. [1 ]
Anuradha, R. [1 ]
Sharma, Ritu [1 ]
Reddy, P. J. [1 ]
Sathian, V. [1 ]
Chaudhury, Probal [1 ]
机构
[1] Bhabha Atom Res Ctr, Radiat Safety Syst Div, Mumbai 400085, India
来源
关键词
CIEMAT/NIST method; Cd-109; Coincidence counting; Conversion electron emission;
D O I
10.1007/s12647-023-00703-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cd-109 is a very important radionuclide and frequently used for calibration of gamma ray spectrometers in low energy region due to its emission of 88 keV photons and long half-life of 461.9 +/- 0.4 days. Due to complex decay scheme standardization of Cd-109 is very challenging and was selected for international intercomparison by Bureau International des Poids et Mesures (BIPM) in 2021.Cd-109 decays via electron capture to the excited state of Ag-109m which decays mainly with emission of conversion electrons with half-life of 39.6 s. Due to this standardization of Cd-109 using conventional 4 pi beta-gamma coincidence method is extremely difficult. Some of the methods for standardization of Cd-109 were measurement of conversion electron emission rate using liquid scintillation spectrometer and CIEMAT/NIST method. BARC is the designated institute (DI) for ionizing radiation of India. In BARC, RSS, RSSD has been entrusted with the responsibilities related to activities of DI for ionizing radiation and hence develops, establishes, maintains and upgrades the primary and secondary standards for ionizing radiation quantities to provide traceability to the ionizing radiation measurements in the country. To establish the degrees of equivalence with the NMIs/DIs of other countries, BARC participated in international intercomparison of activity measurements of Cd-109 (CCRI(II)-K2.Cd-109 key comparison) piloted by BIPM with support of LNE-LNHB, France. The standardization was carried out by CIEMAT/NIST efficiency tracing using H-3 as a tracer and 4 pi liquid scintillation conversion electron measurements. The activity concentration obtained by CIEMAT/ NIST efficiency tracing has the deviation of 0.59% with respect to the value obtained using 4 pi liquid scintillation conversion electron measurements which is within uncertainty limits.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 50 条
  • [21] LSC STANDARDIZATION OF MN-54 IN INORGANIC AND ORGANIC-SAMPLES BY THE CIEMAT/NIST EFFICIENCY TRACING METHOD
    RODRIGUEZ, L
    ARCOS, JML
    GRAU, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 312 (1-2): : 124 - 131
  • [22] Standardization of the EC nuclides 55Fe and 65Zn with the CIEMAT/NIST LSC tracer method
    Gunther, E
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (9-11) : 1055 - 1060
  • [23] MEASUREMENTS OF BETA RAY EMITTERS IN LSC USING EFFICIENCY TRACING CIEMAT/NIST METHOD
    Dobrini, R. I.
    Pavelescu, M.
    Dulama, C. N.
    ROMANIAN JOURNAL OF PHYSICS, 2011, 56 (9-10): : 1148 - 1155
  • [24] Identification of the cadmium binding compounds in Agaricus arvensis hyphae using 109Cd
    Jackl, G.A.
    Reidel, G.
    Kollmer, W.E.
    International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes, 1987, 38 (06): : 431 - 435
  • [25] SIMULTANEOUS ANALYSIS OF TISSUE COMPONENTS BY X AND GAMMA RAYS USING 109CD
    PREUSS, LE
    KOSNIK, LT
    JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (06) : 366 - &
  • [26] Improved cadmium sorption isotherms by the determination of initial contents using the radioisotope 109Cd
    Schug, B
    Düring, RA
    Gäth, S
    JOURNAL OF PLANT NUTRITION AND SOIL SCIENCE, 2000, 163 (02) : 197 - 202
  • [27] A Study on the Behavior of Cadmium in the Soil Solution-Plant System by the Lysimeter Method Using the 109Cd Radioactive Tracer
    Anisimov, Vyacheslav
    Anisimova, Lydia
    Krylenkin, Dmitry
    Dikarev, Dmitry
    Sanzharov, Andrey
    Korneev, Yuri N. N.
    Kostyukov, Ilya
    Kolyagin, Yuri G. G.
    PLANTS-BASEL, 2023, 12 (03):
  • [28] Measurement of the internal conversion electron lines by the track counting technique
    T. A. Islamov
    V. G. Kalinnikov
    N. T. Kambarova
    T. M. Muminov
    N. A. Lebedev
    A. A. Solnyshkin
    Yu. D. Aleshin
    V. V. Kolesnikov
    V. I. Silaev
    Technical Physics Letters, 2001, 27 : 563 - 566
  • [29] Measurement of the internal conversion electron lines by the track counting technique
    Islamov, TA
    Kalinnikov, VG
    Kambarova, NT
    Muminov, TM
    Lebedev, NA
    Solnyshkin, AA
    Aleshin, YD
    Kolesnikov, VV
    Silaev, VI
    TECHNICAL PHYSICS LETTERS, 2001, 27 (07) : 563 - 566
  • [30] Feasibility study. In vivo x-ray fluorescence of iron using 109Cd
    Shukri, A.
    Green, S.
    Bradley, D.A.
    Applied Radiation and Isotopes, 1995, 46 (6-7):