Removal of toxic heavy metal ion from tannery effluent by using Fusarium subglutinans and Hylocereus undatus

被引:3
|
作者
Latha, A. [1 ]
Ganesan, R. [2 ]
Venkatesan, G. [3 ]
Baraneedharan, P. [4 ]
机构
[1] Panimalar Engn Coll, Dept Civil Engn, Chennai, Tamil Nadu, India
[2] Saveetha Inst Med & Tech Sci SIMATS, Saveetha Sch Engn, Dept Civil Engn, Chennai, Tamil Nadu, India
[3] Saveetha Engn Coll, Dept Civil Engn, Chennai, India
[4] Saveetha Engn Coll, Dept Elect & Commun Engn, Chennai 602105, Tamil Nadu, India
关键词
Heavy metal; Dragon fruit peel; Adsorbent dosage; Biosorbent; Kinetic analysis; GREEN SYNTHESIS; AMOXICILLIN; CARBON; NANOPARTICLES; ADSORPTION; TETRACYCLINE; ZEOLITE; BATCH; WATER; DYE;
D O I
10.5004/dwt.2023.29952
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The major sources of aquatic pollution are tannery effluent from tannery industries. One of method for removing harmful metals from natural water and commercial refuse sources is biosorption of heavy metals. The chrome tannery wastewater sample was procured from State Industries Promotion Corporation of Tamil Nadu Ltd (SIPCOT). To isolate the metal-tolerant fungus with the ability to absorb heavier metal chromium, the gathered specimens were serially reduced. It offers a possible substitute for the traditional method of eliminating metals. The filtered fungal biomass Fusarium subglutinans and agrowaste biosorbent Hylocereus undatus are used to remove the Cr6+ which is present in tannery effluent. The atomic absorption spectrophotometer was used to ascertain the remaining Cr level in solution. The highest % elimination of Cr6+ for the mixed biosorbent was determined to be 98.67% at 50 mg/L starting Cr6+ content, 5 g biosorbent dose, pH 2.0, and 150 rpm agitation speed at room temperature. The optimal period for Cr6+ biosorption on the biosorbent was 60 min. Finding the biosorption process efficiency requires determining its balance. The equilibrium parameters were examined. The association coefficient (R-2) for mixed biosorbent was discovered to be in the following order: Redlich-Peterson (0.9877) > Langmuir (0.8319) > Sips (0.7913) > Freundlich (0.5769). The findings indicated that mixed biosorbent had the capability to remove Cr6+, and the amount of Cr6+ removed from chrome tannery wastewater was determined to be 99.87%. The elimination of Cr6+ from chrome tannery wastewater is a practical, affordable, and environmentally beneficial procedure, according to the analysis of the processed effluent.
引用
收藏
页码:70 / 78
页数:9
相关论文
共 50 条
  • [31] A review of polyampholytic ion scavengers for toxic metal ion removal from aqueous systems
    Stala, Lukasz
    Ulatowska, Justyna
    Polowczyk, Izabela
    WATER RESEARCH, 2021, 203 (203)
  • [32] Effect of sulfide and hydroxide on the removal of heavy metal ions from hydrometallurgical zinc effluent
    Najafi, A.
    Asjadi, F.
    Safari, A.A.
    International Journal of Environmental Analytical Chemistry, 2024, 104 (18): : 6370 - 6384
  • [33] Effect of sulfide and hydroxide on the removal of heavy metal ions from hydrometallurgical zinc effluent
    Najafi, A.
    Asjadi, F.
    Safari, A. A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024, 104 (18) : 6370 - 6384
  • [34] Comparative Studies on Accumulation of Cr from Metal Solution and Tannery Effluent under Repeated Metal Exposure by Aquatic Plants: Its Toxic Effects
    Sarita Sinha
    Rohit Saxena
    Shraddha Singh
    Environmental Monitoring and Assessment, 2002, 80 : 17 - 31
  • [35] Comparative studies on accumulation of Cr from metal solution and tannery effluent under repeated metal exposure by aquatic plants: Its toxic effects
    Sinha, S
    Saxena, R
    Singh, S
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2002, 80 (01) : 17 - 31
  • [36] Heavy Metal Ion Effluent Discharge Containment Using Magnesium Oxide (MgO) Nanoparticles
    Madzokere, Tatenda C.
    Karthigeyan, A.
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (01) : 9 - 18
  • [37] Isolation and Characterization of Bioremediation Potent Microorganisms from Spectrophotometrically Analysed Heavy Metal (Cr and Cd)-Rich Tannery Effluent
    Mukherjee, Debjani
    Panwar, Joginder Singh
    Kumar, Mohit
    Thakur, Yashika
    Kumari, Kalpana
    Singhania, Shweta
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2015, 6 (03): : 760 - 766
  • [38] OCCURRENCE OF HEAVY METAL RESISTANCE IN Sinorhizobium sp. ISOLATED FROM ROOT NODULES OF FENUGREEK, TREATED WITH TANNERY EFFLUENT
    Altaf, Mohd Musheer
    APPLIED BIOLOGICAL RESEARCH, 2020, 22 (01) : 55 - 60
  • [39] A heavy metal tolerant novel bacterium, Bacillus malikii sp nov., isolated from tannery effluent wastewater
    Abbas, Saira
    Ahmed, Iftikhar
    Kudo, Takuji
    Iqbal, Muhammad
    Lee, Yong-Jae
    Fujiwara, Toru
    Ohkuma, Moriya
    ANTONIE VAN LEEUWENHOEK INTERNATIONAL JOURNAL OF GENERAL AND MOLECULAR MICROBIOLOGY, 2015, 108 (06): : 1319 - 1330
  • [40] Study of heavy metal removal from heavy metal mixture using the CCD method
    Demim, S.
    Drouiche, N.
    Aouabed, A.
    Benayad, T.
    Couderchet, M.
    Semsari, S.
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2014, 20 (02) : 512 - 520