NiFe2O4/G-C3N4 modified pencil graphite electrode for mercury (II) detection

被引:3
|
作者
Yogeeshwari, R. [1 ,2 ]
Krishna, R. Hari [1 ,6 ]
Adarakatti, Prashanth S. [3 ]
Kumar, S. Girish [4 ]
Siddaramanna, Ashoka [5 ]
机构
[1] Visvesvaraya Technol Univ, M S Ramaiah Inst Technol, Dept Chem, Bengaluru 560054, India
[2] Seshadripuram Coll, Dept Chem, Bengaluru 560020, India
[3] SVM Arts Sci & Commerce Coll, Dept Chem, Ilkal 587125, India
[4] RV Coll Engn, Dept Chem, Bengaluru 560059, India
[5] REVA Univ, Sch Appl Sci, Dept Chem, Bengaluru 560064, India
[6] M S Ramaiah Inst Technol, Ctr Bio & Energy Mat Innovat, Bengaluru 560054, India
来源
关键词
NiFe2O4; G-C3N4; Pencil graphite electrode; Electrochemical sensor; Hg(II) detection; GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL DETECTION; ELECTROCATALYTIC DETERMINATION; PASTE ELECTRODE; SENSOR; NANOCOMPOSITE; NANOPARTICLES; HG(II); EVOLUTION; WATER;
D O I
10.1016/j.apsadv.2023.100475
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The design and development of composite electrodes towards the trace-level detection of Hg(II) ions has triggered paramount importance in the area of electrochemistry. In this context, pencil graphite electrode was modified with NiFe2O4/G-C3N4, wherein bimetallic oxides were heterogeneously grown over the g-C3N4 sheets through a wet chemical approach. The results derived from transmission electron microscopy and X-ray diffraction analysis indeed reflected that NiFe2O4 were uniformly distributed over the sheet surface and complemented with effective interactions between them. The composites were coated over a pencil graphite electrode (PGE) and were used for the electrochemical detection of Hg(II) ions under various conditions. The cyclic voltammetry (CV) and differential pulse anodic stripping voltammetry (DPASV) reveal better electrochemical performance of modified electrodes compared to bare PGE, G-C3N4/PGE, and NiFe2O4/PGE. The improved charge transfer kinetics at the electrode-electrolyte interface were the dominant factor to exhibit higher performance. The proposed sensor showed acceptable reproducibility and stability under the optimal reaction conditions. Additionally, the sensor showed a broad linear range from 10 to 800 nM with a limit of detection (LOD) of 2.49 nM. Further, the fabricated sensor has been successfully employed to determine Hg(II) contents in real water sample matrices.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] The research of lead ion detection based on rGO/g-C3N4 modified glassy carbon electrode
    Fu, Rui
    Yu, Ping
    Wang, Min
    Sun, Jie
    Chen, Da
    Jin, Chongyue
    Li, Zhilin
    MICROCHEMICAL JOURNAL, 2020, 157
  • [42] Utilizing three-dimensional ordered macroporous NiFe2O4 Loaded With g-C3N4 as a heterogeneous photo-Fenton catalyst for tetracycline degradation
    Wen, Fushan
    Li, Yajie
    Huang, Xiaoli
    Pang, Le
    Zhang, Tao
    Xu, Yuan
    JOURNAL OF ALLOYS AND COMPOUNDS, 2023, 958
  • [43] Utilizing three-dimensional ordered macroporous NiFe2O4 Loaded With g-C3N4 as a heterogeneous photo-Fenton catalyst for tetracycline degradation
    Wen, Fushan
    Li, Yajie
    Huang, Xiaoli
    Pang, Le
    Zhang, Tao
    Xu, Yuan
    Journal of Alloys and Compounds, 2023, 958
  • [44] Effect of Different g-C3N4 Content on Properties of NiCo2S4/g-C3N4 Composite as Electrode Material for Supercapacitor
    Ding, Meijie
    Wei, Zhiqiang
    Zhu, Xiaojun
    Liu, Dexue
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (12):
  • [45] Composite g-C3N4/NiCo2O4with Excellent Electrochemical Impedance as an Electrode for Supercapacitors
    Cui, Danfeng
    Fan, Zheng
    Fan, Yanyun
    Chen, Hongmei
    Li, Penglu
    Duan, Xiaoya
    Yan, Shubin
    Xu, Hongyan
    Xue, Chenyang
    Journal of Nanomaterials, 2022, 2022
  • [46] Composite g-C3N4/NiCo2O4 with Excellent Electrochemical Impedance as an Electrode for Supercapacitors
    Cui, Danfeng
    Fan, Zheng
    Fan, Yanyun
    Chen, Hongmei
    Li, Penglu
    Duan, Xiaoya
    Yan, Shubin
    Xu, Hongyan
    Xue, Chenyang
    JOURNAL OF NANOMATERIALS, 2022, 2022
  • [47] Adsorption ability of aqueous lead (II) by NiFe2O4 and 2D- rGO decorated NiFe2O4 nanocomposite
    B. Carmel Jeeva Mary
    J. Judith Vijaya
    M. Bououdina
    L. John Kennedy
    L. Khezami
    A. Modwi
    Journal of Materials Science: Materials in Electronics, 2023, 34
  • [48] Adsorption ability of aqueous lead (II) by NiFe2O4 and 2D-rGO decorated NiFe2O4 nanocomposite
    Mary, B. Carmel Jeeva
    Vijaya, J. Judith
    Bououdina, M.
    Kennedy, L. John
    Khezami, L.
    Modwi, A.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2023, 34 (09)
  • [49] Visible light–driven photocatalytic degradation of atrazine in aqueous phase: impact of the g-C3N4/TiO2/NiFe2O4 nanocomposite activated by potassium peroxymonosulfate
    Altendji, Khaoula
    Hamoudi, Safia
    Environmental Science and Pollution Research, 2025, 32 (03) : 1361 - 1374
  • [50] An innovative Z-scheme g-C3N4/ZnO/NiFe2O4 heterostructure for the concomitant photocatalytic removal and real-time monitoring of noxious fluoroquinolones
    Garg, Twinkle
    Renu
    Kaur, Jaspreet
    Kaur, Paramdeep
    Nitansh
    Kumar, Vinod
    Tikoo, Kulbhushan
    Kaushik, Anupama
    Singhal, Sonal
    CHEMICAL ENGINEERING JOURNAL, 2022, 443