The value of conventional ultrasound combined with superb microvascular imaging and color Doppler flow imaging in the diagnosis of thyroid malignant nodules: a systematic review and meta-analysis

被引:9
|
作者
Jiang, Li [1 ,2 ]
Zhang, Dian [2 ]
Chen, Yue-Nan [2 ]
Yu, Xue-Juan [2 ]
Pan, Mei-Fang [2 ]
Lian, Lian [1 ,3 ]
机构
[1] Yangzhou Univ, Med Coll, Yangzhou, Jiangsu, Peoples R China
[2] Suzhou Xiangcheng Peoples Hosp, Dept Ultrasound, Suzhou, Jiangsu, Peoples R China
[3] Suzhou Xiangcheng Peoples Hosp, Dept Oncol, Suzhou, Jiangsu, Peoples R China
来源
关键词
malignant; thyroid nodules; ultrasonography; Superb microvascular imaging; color Doppler flow imaging; meta-analysis; SONOGRAPHIC FEATURES; MICROVESSEL DENSITY; ULTRASONOGRAPHY; QUANTIFICATION; MANAGEMENT; BENIGN; SIZE;
D O I
10.3389/fendo.2023.1182259
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate and compare the value of conventional ultrasound-based superb microvascular imaging (SMI) and color Doppler flow imaging (CDFI) in the diagnosis of malignant thyroid nodule by meta-analysis.Methods: The literature included in the Cochrane Library, PubMed, and Embase were searched by using " superb microvascular imaging (SMI), color Doppler flow imaging (CDFI), ultrasound, thyroid nodules" as the keywords from inception through February 1, 2023. According to the inclusion and exclusion criteria, the clinical studies using SMI and CDFI to diagnose thyroid nodules were selected, and histopathology of thyroid nodules was used as reference standard. The diagnostic accuracy research quality assessment tool (QUADAS-2) was used to evaluate the quality of included literature, and the Review Manager 5.4 was used to make the quality evaluation chart. The heterogeneity test was performed on the literature that met the requirements, the combined sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were pooled, and a comprehensive ROC curve analysis was performed. Meta-DiSc version 1.4, StataSE 12, and Review Manager 5.4 software were used.Results: Finally, 13 studies were included in this meta-analysis. A total of 815 thyroid malignant nodules were assessed. All thyroid nodules were histologically confirmed after SMI or CDFI. The combined sensitivity, specificity, PLR, NLR, DOR, and area under the SROC curve of SMI for the diagnosis of malignant thyroid nodules were 0.80(95%CI: 0.77-0.83), 0.79(95%CI: 0.77-0.82), 4.37(95%CI: 3.0-6.36), 0.23(95%CI: 0.15-0.35), 22.29(95%CI: 12.18-40.78), and 0.8944, respectively; the corresponding values of CDFI were 0.62(95%CI: 0.57-0.67), 0.81(95%CI: 0.78-0.85), 3.33(95%CI: 2.18-5.07), 0.41(95%CI: 0.27-0.64), 8.93(95%CI: 3.96-20.16), and 0.8498. Deek funnel pattern showed no significant publication bias.Conclusion: The diagnostic efficiency of SMI for malignant thyroid nodules is better than CDFI, and SMI technology can provide significantly more information on vascularity, make up for the deficiency of CDFI, and has better clinical application value.Systematic review registrationhttps://www.crd.york.ac.uk/PROSPERO, identifier CRD42023402064.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] The comparative study of color doppler flow imaging, superb microvascular imaging, contrast-enhanced ultrasound micro flow imaging in blood flow analysis of solid renal mass
    Mao, Yiran
    Mu, Jie
    Zhao, Jing
    Yang, Fan
    Zhao, Lihui
    [J]. CANCER IMAGING, 2022, 22 (01)
  • [32] The comparative study of color doppler flow imaging, superb microvascular imaging, contrast-enhanced ultrasound micro flow imaging in blood flow analysis of solid renal mass
    Yiran Mao
    Jie Mu
    Jing Zhao
    Fan Yang
    Lihui Zhao
    [J]. Cancer Imaging, 22
  • [33] Systematic review and meta-analysis of ultrasonic elastography in the diagnosis of benign and malignant thyroid nodules
    Zhou, Ying
    Chen, Huali
    Qiang, Jialin
    Wang, Dandan
    [J]. GLAND SURGERY, 2021, 10 (09) : 2734 - 2744
  • [34] Diagnostic value of combined ultrasound contrast and elastography for differentiating benign and malignant thyroid nodules: a meta-analysis
    Liu, Funing
    Wang, Yihan
    Xiong, Yu
    Li, Xin
    Yao, Jun
    Ju, Hao
    Ren, Fu
    Zhang, Luwei
    Wang, Hongbo
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01):
  • [35] An analysis of the clinical value of high-frequency color Doppler ultrasound in the differential diagnosis of benign and malignant thyroid nodules
    Deng, Shuhao
    Jiang, Quan
    Zhu, Yicheng
    Zhang, Yuan
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (03): : 2331 - 2336
  • [36] Superb microvascular imaging evaluating joint lesion scores in rheumatoid arthritis compared with power Doppler imaging A meta-analysis
    Lin, MingXin
    Wang, Cong
    [J]. MEDICINE, 2020, 99 (37) : E22185
  • [37] Diagnostic performance of ACR-TIRADS combined with superb microvascular imaging for differential diagnosis of mummified thyroid nodules and papillary thyroid carcinomas
    Tian, Jiali
    Liang, Jinlei
    Lin, Yuhong
    Wang, Liping
    Chen, Xiaobo
    [J]. ENDOCRINE CONNECTIONS, 2024, 13 (03)
  • [38] Clinical Research of Thyroid Imaging Reporting and Data System Classification Combined with Color-Doppler Blood-Flow Parameters in Diagnosis of Benign and Malignant Thyroid Nodules
    Wang, Hongzhu
    Yu, Da
    Bao, Kunzhong
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (07) : 1564 - 1569
  • [39] Tissue Doppler imaging for diagnosis of coronary artery disease: a systematic review and meta-analysis
    Agarwal, Rajender
    Gosain, Priyanka
    Kirkpatrick, James N.
    Alyousef, Tareq
    Doukky, Rami
    Singh, Gurpreet
    Umscheid, Craig A.
    [J]. CARDIOVASCULAR ULTRASOUND, 2012, 10
  • [40] Tissue Doppler imaging for diagnosis of coronary artery disease: a systematic review and meta-analysis
    Rajender Agarwal
    Priyanka Gosain
    James N Kirkpatrick
    Tareq Alyousef
    Rami Doukky
    Gurpreet Singh
    Craig A Umscheid
    [J]. Cardiovascular Ultrasound, 10