The value of conventional ultrasound combined with superb microvascular imaging and color Doppler flow imaging in the diagnosis of thyroid malignant nodules: a systematic review and meta-analysis

被引:9
|
作者
Jiang, Li [1 ,2 ]
Zhang, Dian [2 ]
Chen, Yue-Nan [2 ]
Yu, Xue-Juan [2 ]
Pan, Mei-Fang [2 ]
Lian, Lian [1 ,3 ]
机构
[1] Yangzhou Univ, Med Coll, Yangzhou, Jiangsu, Peoples R China
[2] Suzhou Xiangcheng Peoples Hosp, Dept Ultrasound, Suzhou, Jiangsu, Peoples R China
[3] Suzhou Xiangcheng Peoples Hosp, Dept Oncol, Suzhou, Jiangsu, Peoples R China
来源
关键词
malignant; thyroid nodules; ultrasonography; Superb microvascular imaging; color Doppler flow imaging; meta-analysis; SONOGRAPHIC FEATURES; MICROVESSEL DENSITY; ULTRASONOGRAPHY; QUANTIFICATION; MANAGEMENT; BENIGN; SIZE;
D O I
10.3389/fendo.2023.1182259
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate and compare the value of conventional ultrasound-based superb microvascular imaging (SMI) and color Doppler flow imaging (CDFI) in the diagnosis of malignant thyroid nodule by meta-analysis.Methods: The literature included in the Cochrane Library, PubMed, and Embase were searched by using " superb microvascular imaging (SMI), color Doppler flow imaging (CDFI), ultrasound, thyroid nodules" as the keywords from inception through February 1, 2023. According to the inclusion and exclusion criteria, the clinical studies using SMI and CDFI to diagnose thyroid nodules were selected, and histopathology of thyroid nodules was used as reference standard. The diagnostic accuracy research quality assessment tool (QUADAS-2) was used to evaluate the quality of included literature, and the Review Manager 5.4 was used to make the quality evaluation chart. The heterogeneity test was performed on the literature that met the requirements, the combined sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were pooled, and a comprehensive ROC curve analysis was performed. Meta-DiSc version 1.4, StataSE 12, and Review Manager 5.4 software were used.Results: Finally, 13 studies were included in this meta-analysis. A total of 815 thyroid malignant nodules were assessed. All thyroid nodules were histologically confirmed after SMI or CDFI. The combined sensitivity, specificity, PLR, NLR, DOR, and area under the SROC curve of SMI for the diagnosis of malignant thyroid nodules were 0.80(95%CI: 0.77-0.83), 0.79(95%CI: 0.77-0.82), 4.37(95%CI: 3.0-6.36), 0.23(95%CI: 0.15-0.35), 22.29(95%CI: 12.18-40.78), and 0.8944, respectively; the corresponding values of CDFI were 0.62(95%CI: 0.57-0.67), 0.81(95%CI: 0.78-0.85), 3.33(95%CI: 2.18-5.07), 0.41(95%CI: 0.27-0.64), 8.93(95%CI: 3.96-20.16), and 0.8498. Deek funnel pattern showed no significant publication bias.Conclusion: The diagnostic efficiency of SMI for malignant thyroid nodules is better than CDFI, and SMI technology can provide significantly more information on vascularity, make up for the deficiency of CDFI, and has better clinical application value.Systematic review registrationhttps://www.crd.york.ac.uk/PROSPERO, identifier CRD42023402064.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Diagnostic value of superb microvascular imaging and color doppler for thyroid nodules: A meta-analysis
    Luo, Haorou
    Yin, Lixue
    [J]. FRONTIERS IN ONCOLOGY, 2023, 13
  • [2] The value of color Doppler ultrasound in the diagnosis of thyroid nodules: a systematic review and meta-analysis
    Zhao, Danbo
    Jing, Yi
    Lin, Xiaoyi
    Zhang, Bixia
    [J]. GLAND SURGERY, 2021, 10 (12) : 3369 - 3377
  • [3] The value of TI-RADS combined with superb microvascular imaging in distinguishing thyroid nodules: A protocol for systematic review and meta-analysis
    Wang, Cong
    Lin, Mingxin
    Zhong, Lin
    Tian, Congliang
    [J]. PLOS ONE, 2021, 16 (01): : e0245035
  • [4] Superb microvascular imaging for distinguishing thyroid nodules A meta-analysis (PRISMA)
    Jin, Hui
    Wang, Cong
    Jin, Xin
    [J]. MEDICINE, 2022, 101 (24) : E29505
  • [5] A Prospective Study to Compare Superb Microvascular Imaging with Grayscale Ultrasound and Color Doppler Flow Imaging of Vascular Distribution and Morphology in Thyroid Nodules
    Zhu, Yi-Cheng
    Zhang, Yuan
    Deng, Shu-Hao
    Jiang, Quan
    [J]. MEDICAL SCIENCE MONITOR, 2018, 24 : 9223 - 9231
  • [6] The value of superb microvascular imaging (SMI) scoring assignment method in differentiating benign and malignant thyroid nodules by conventional ultrasound
    Zhao, Wei
    Lu, Ruigang
    Yin, Li
    Guo, Ruijun
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 78 (04) : 355 - 363
  • [7] Superb microvascular imaging (SMI) compared with conventional ultrasound for evaluating thyroid nodules
    Ruigang Lu
    Yuxin Meng
    Yan Zhang
    Wei Zhao
    Xun Wang
    Mulan Jin
    Ruijun Guo
    [J]. BMC Medical Imaging, 17
  • [8] Superb microvascular imaging (SMI) compared with conventional ultrasound for evaluating thyroid nodules
    Lu, Ruigang
    Meng, Yuxin
    Zhang, Yan
    Zhao, Wei
    Wang, Xun
    Jin, Mulan
    Guo, Ruijun
    [J]. BMC MEDICAL IMAGING, 2017, 17
  • [9] The diagnostic accuracy of superb microvascular imaging in distinguishing thyroid nodules A protocol for systematic review and meta analysis
    Tian, Congliang
    Wang, Zinan
    Hou, Xiukun
    Wang, Cong
    [J]. MEDICINE, 2020, 99 (40) : E22350
  • [10] Diagnostic Value of Superb Microvascular Imaging in Differentiating Benign and Malignant Breast Tumors: A Systematic Review and Meta-Analysis
    Feng, Jiaping
    Lu, Jianghao
    Jin, Chunchun
    Chen, Yihao
    Chen, Sihan
    Guo, Guoqiang
    Gong, Xuehao
    [J]. DIAGNOSTICS, 2022, 12 (11)