The Strategy of Continuous Commutation Failure Suppression by Combining Turn-off Angle Compensation and Dynamic Nonlinear VDCOL

被引:0
|
作者
Liu, Hewei [1 ]
Jin, Guobin [1 ]
机构
[1] Northeast Elect Power Univ, Key Lab Modern Power Syst Simulat Control & New Gr, Minist Educ, Jilin 132012, Peoples R China
关键词
continuous commutation failure; LCC-HVDC; dynamic nonlinear VDCOL; extinction angle; DC rate of change; LCC-HVDC; MITIGATION;
D O I
10.3390/su16052145
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In recent years, with the continuous growth in China's economy, the continuous advancement of urbanization and industrialization, the contradiction between rapid economic development and the continuous reduction in traditional fossil energy reserves such as coal, oil, and natural gas, the continuous aggravation of environmental pollution has become increasingly prominent. In this era, clean energy power generation technologies such as hydropower, wind power, and solar power generation, which have the advantages of renewability, environmental protection, and economy, have developed rapidly. However, wind and photovoltaic power plants are often located in remote areas, which means significant losses in the transmission process. High-voltage direct current (HVDC) transmission technology becomes the best choice to solve this problem. The HVDC transmission system based on a grid commutator is widely used in China's AC-DC hybrid power grid. When an AC fault occurs on the inverter side, the line-commutated converter high-voltage direct current (LCC-HVDC) system is more prone to continuous commutation failure, which brings serious harm to system operation. To better suppress the problem of continuous commutation failure on the contravariant side, this paper analyzes the mechanism of continuous commutation failure from multiple angles. The DC current command sensitivity of a voltage-dependent current order limiter (VDCOL) in the LCC-HVDC system is low, which will lead to different degrees of continuous commutation failure. In addition, the rapid rise in DC current and the drop in commutation voltage during the fault will cause the turn-off angle to drop, and the probability of continuous commutation failure of the system will increase significantly. Based on the above theoretical analysis, a new control strategy combining the dynamic compensation of the turn-off angle of a virtual inductor and the suppression of continuous commutation failure by dynamic nonlinear VDCOL is proposed. A dynamic nonlinear VDCOL control strategy is proposed for the low sensitivity of current command adjustment under conventional VDCOL control. Secondly, two concepts of virtual inductance and DC current change rate are introduced, and a control strategy based on virtual inductance is proposed to comprehensively ensure that the switching angle has sufficient commutation margin during fault recovery. Finally, based on the CIGRE standard test model in PSCAD/EMTDC, the accuracy of the correlation mechanism analysis and the effectiveness of the suppression method are verified.
引用
收藏
页数:20
相关论文
共 23 条
  • [1] A suppression method based on nonlinear VDCOL to mitigate the continuous commutation failure
    Meng Q.
    Liu Z.
    Hong L.
    Zhou X.
    Xia H.
    Liu Y.
    Wang X.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (07): : 119 - 127
  • [2] Continuous commutation failure suppression strategy based on firing angle deviation compensation
    Zhao J.
    Li X.
    Wang Y.
    Tan Z.
    Wang J.
    Cai Z.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2023, 43 (03): : 210 - 216
  • [3] A Suppression Method of Commutation Failure in LCC-UHVDC Systems Based on the Dynamic Tracking of the Turn-Off Angle Setting Value
    Wang, Hua
    Zheng, Ao
    Liu, Ziwen
    Liu, Wei
    Pan, Xueqing
    Tian, Chunsun
    ELECTRONICS, 2024, 13 (07)
  • [4] Continuous commutation failure suppression method based on dynamic compensation of firing angle deviation
    Wang, Yulin
    Li, Xiaohua
    Cai, Zexiang
    Zhao, Jun
    Guo, Yaxun
    Wang, Juanjuan
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 147
  • [5] A Dynamic Nonlinear VDCOL Control Strategy Based on the Taylor Expansion of DC Voltages for Suppressing the Subsequent Commutation Failure in HVDC Transmission
    Li, Hongzheng
    Han, Kunlun
    Liu, Shuhao
    Chen, Hailin
    Zhang, Xiongfeng
    Zou, Kangtai
    ENERGIES, 2023, 16 (21)
  • [6] Continuous commutation failure suppression and coordinated recovery of multi-infeed DC system based on improved VDCOL
    Zhang W.
    Xiong Y.
    Li C.
    Yao W.
    Wen J.
    Gao D.
    1600, Power System Protection and Control Press (48): : 63 - 72
  • [7] Novel control strategy of turn-on angle and turn-off angle for doubly salient permanent magnet motor
    Aero-Power Sci.-Technol. Center, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (24): : 68 - 73
  • [8] Continuous Commutation Failure Suppression Based on Actual Firing Angle Response
    Wang Y.
    Li X.
    Li S.
    Guo Y.
    Wang J.
    Wang X.
    Dianwang Jishu/Power System Technology, 2024, 48 (06): : 2632 - 2641
  • [9] Subsequent commutation failure suppression strategy of hybrid cascaded HVDC system based on coordinated control of CEC and VDCOL
    Wang, He
    Zhang, Daqian
    Bian, Jing
    Guo, Jiazhi
    Li, Shiqiang
    IET ENERGY SYSTEMS INTEGRATION, 2024, 6 : 932 - 945
  • [10] An Improved LCC Model Considering Dynamic Behavior of Thyristor During Turn-Off Period and Its Impact on Commutation Failure Identification
    Guo, Chunyi
    Jiang, Fan
    Ye, Yunxia
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (05) : 2653 - 2665