Clinical Retinal Image Quality of a Non-diffractive Wavefront-Shaping Extended Depth of Focus (Vivity) Intraocular Lens

被引:7
|
作者
Al-Amri, Saad Abdulrahman J. [1 ,2 ,3 ]
Alio, Jorge L. [1 ,3 ]
Milan-Castillo, Roberto [1 ]
D'Oria, Francesco [1 ,4 ]
Martinez-Abad, Antonio [1 ]
Yebana, Pilar [1 ]
Subirana, Nuria [1 ]
Al-Harbi, Ziyad [1 ,5 ]
Plaza-Puche, Ana B. [1 ]
Alio del Barrio, Jorge L. [1 ,3 ]
机构
[1] VISSUM Miranza Grp, Cornea Cataract & Refract Surg Unit, Alicante, Spain
[2] Prince Sultan Med Mil City, Dept Ophthalmol, Riyadh, Saudi Arabia
[3] Univ Miguel Hernandez, Dept Ophthalmol, Alicante, Spain
[4] Univ Bari, Sect Ophthalmol, Dept Basic Med Sci Neurosci & Sense Organs, Bari, Italy
[5] Al Nakheel Med Ctr, Riyadh, Saudi Arabia
关键词
PATIENT SATISFACTION; IOL DESIGNS; OUTCOMES; RANGE;
D O I
10.3928/1081597X-20221130-04
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate clinical retinal optical image quality following implantation of an extended depth of focus intraocular lens (EDOF IOL) (Vivity; Alcon Laboratories, Inc), and to compare it with a monofocal and a trifocal IOL. METHODS: This prospective, comparative, case-control study included 88 eyes implanted with: (1) 19 monofocal IOLs (AcrySof SA60AT; Alcon Laboratories, Inc); (2) 38 EDOF IOLs (AcrySof IQ Vivity); and (3) 31 trifocal IOLs (AT LISA tri 839MP; Carl Zeiss Meditec AG). Total root mean square, ocular lower (LOA) and higher (HOA) order aberrations, point spread function (PSF) Strehl ratio (PSF with LOA), and PSF Strehl ratio excluding LOA (PSF without LOA) were analyzed using a Pyramidal WaveFront-based sensor aberrometer Osiris (Costruzione Strumenti Oftalmici) at two different pupil sizes (3 and 4 mm). RESULTS: The trifocal IOL showed the highest PSF without LOA at both pupil sizes (0.52 +/- 0.12 and 0.31 +/- 0.07, respectively), followed by the AcrySof SA60AT (0.39 +/- 0.10 and 0.27 +/- 0.07) and AcrySof IQ Vivity (0.34 +/- 0.11 and 0.24 +/- 0.09) (P <.001). The AcrySof IQ Vivity and monofocal IOLs were comparable (P >.05). Despite the comparable postoperative low spherical equivalent among the IOL groups, the AT LISA tri 839MP retinal image quality (PSF with LOA) was the most severely affected by such residual refractive errors (dropped to 0.26 +/- 0.06 at 3 mm; P <.001) compared to the monofocal AcrySof SA60AT (0.24 +/- 0.07 at 3 mm) and EDOF Acrysof IQ Vivity (0.23 +/- 0.06 at 3 mm) groups. The PSF with LOA was comparable (P >.05) among the three groups at both the 3and 4-mm pupil size. CONCLUSIONS: Although trifocal IOLs provided significantly better retinal image quality if influence of LOA is excluded, they also demonstrated to be the most sensitive to residual refractive errors. Both the EDOF Acrysof IQ Vivity and monofocal AcrySof SA60AT IOLs showed a comparable retinal image quality, and they are also comparable with trifocal IOLs when considering the clinically real PSF (PSF with LOA).
引用
收藏
页码:103 / +
页数:9
相关论文
共 50 条
  • [21] Cases of replacing diffractive bifocal intraocular lens with extended depth of focus intraocular lens due to waxy vision
    Takabatake, Ryu
    Takahashi, Makiko
    Yoshimoto, Takuya
    Higashijima, Fumiaki
    Kobayashi, Yuka
    Yamashiro, Chiemi
    Kimura, Kazuhiro
    PLOS ONE, 2021, 16 (10):
  • [22] Evaluation of Visual and Patient-Reported Outcomes, Spectacle Dependence after Bilateral Implantation with a Non-Diffractive Extended Depth of Focus Intraocular Lens Compared to Other Intraocular Lenses
    Dolowiec-Kwapisz, Anna
    Piotrowska, Halina
    Misiuk-Hojlo, Marta
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (17)
  • [23] Visual outcomes of non-diffractive extended-depth-of-focus and enhanced monofocal intraocular lenses: A case-control study
    Sabur, Huri
    Unsal, Ugur
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 262 - 268
  • [24] Comparative Visual Outcome Analysis of a Diffractive Multifocal Intraocular Lens and a New Diffractive Multifocal Lens with Extended Depth of Focus
    Moshirfar, Majid
    Stapley, Seth R.
    Corbin, Wyatt M.
    Bundogji, Nour
    Conley, Matthew
    Darquea, Ines M.
    Ronquillo, Yasmyne C.
    Hoopes, Phillip C.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [25] Design of double-zone aspheric diffractive intraocular lens with extended depth of focus
    边亚燕
    刘永基
    姜来
    Chinese Optics Letters, 2018, 16 (09) : 81 - 88
  • [26] Design of double-zone aspheric diffractive intraocular lens with extended depth of focus
    Bian, Yayan
    Liu, Yongji
    Jiang, Lai
    CHINESE OPTICS LETTERS, 2018, 16 (09)
  • [27] Assessment of the image quality of extended depth-of-focus intraocular lens models in polychromatic light
    Lee, Yumi
    Labuz, Grzegorz
    Son, Hyeck-Soo
    Yildirim, Timur M.
    Khoramnia, Ramin
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01): : 108 - 115
  • [28] Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation
    Jeon, Sohee
    Choi, Ayoung
    Kwon, Hyunggoo
    PLOS ONE, 2022, 17 (11):
  • [29] Visual outcomes and rotational stability of a new non-diffractive extended-vision toric intraocular lens
    Nguyen, Michael Trong Duc
    Yuan, Po Hsiang
    Bachour, Kenan
    Sierra, Maria Camila Aguilar
    Durr, Georges M.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2024, 59 (04): : 234 - 240
  • [30] Clinical outcomes after implantation of extended depth-of-focus AcrySof® Vivity® intraocular lens in eyes with low-grade epiretinal membrane
    Jeon, Sohee
    Choi, Ayoung
    Kwon, Hyunggoo
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (12) : 3883 - 3888