Clinical Retinal Image Quality of a Non-diffractive Wavefront-Shaping Extended Depth of Focus (Vivity) Intraocular Lens

被引:7
|
作者
Al-Amri, Saad Abdulrahman J. [1 ,2 ,3 ]
Alio, Jorge L. [1 ,3 ]
Milan-Castillo, Roberto [1 ]
D'Oria, Francesco [1 ,4 ]
Martinez-Abad, Antonio [1 ]
Yebana, Pilar [1 ]
Subirana, Nuria [1 ]
Al-Harbi, Ziyad [1 ,5 ]
Plaza-Puche, Ana B. [1 ]
Alio del Barrio, Jorge L. [1 ,3 ]
机构
[1] VISSUM Miranza Grp, Cornea Cataract & Refract Surg Unit, Alicante, Spain
[2] Prince Sultan Med Mil City, Dept Ophthalmol, Riyadh, Saudi Arabia
[3] Univ Miguel Hernandez, Dept Ophthalmol, Alicante, Spain
[4] Univ Bari, Sect Ophthalmol, Dept Basic Med Sci Neurosci & Sense Organs, Bari, Italy
[5] Al Nakheel Med Ctr, Riyadh, Saudi Arabia
关键词
PATIENT SATISFACTION; IOL DESIGNS; OUTCOMES; RANGE;
D O I
10.3928/1081597X-20221130-04
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate clinical retinal optical image quality following implantation of an extended depth of focus intraocular lens (EDOF IOL) (Vivity; Alcon Laboratories, Inc), and to compare it with a monofocal and a trifocal IOL. METHODS: This prospective, comparative, case-control study included 88 eyes implanted with: (1) 19 monofocal IOLs (AcrySof SA60AT; Alcon Laboratories, Inc); (2) 38 EDOF IOLs (AcrySof IQ Vivity); and (3) 31 trifocal IOLs (AT LISA tri 839MP; Carl Zeiss Meditec AG). Total root mean square, ocular lower (LOA) and higher (HOA) order aberrations, point spread function (PSF) Strehl ratio (PSF with LOA), and PSF Strehl ratio excluding LOA (PSF without LOA) were analyzed using a Pyramidal WaveFront-based sensor aberrometer Osiris (Costruzione Strumenti Oftalmici) at two different pupil sizes (3 and 4 mm). RESULTS: The trifocal IOL showed the highest PSF without LOA at both pupil sizes (0.52 +/- 0.12 and 0.31 +/- 0.07, respectively), followed by the AcrySof SA60AT (0.39 +/- 0.10 and 0.27 +/- 0.07) and AcrySof IQ Vivity (0.34 +/- 0.11 and 0.24 +/- 0.09) (P <.001). The AcrySof IQ Vivity and monofocal IOLs were comparable (P >.05). Despite the comparable postoperative low spherical equivalent among the IOL groups, the AT LISA tri 839MP retinal image quality (PSF with LOA) was the most severely affected by such residual refractive errors (dropped to 0.26 +/- 0.06 at 3 mm; P <.001) compared to the monofocal AcrySof SA60AT (0.24 +/- 0.07 at 3 mm) and EDOF Acrysof IQ Vivity (0.23 +/- 0.06 at 3 mm) groups. The PSF with LOA was comparable (P >.05) among the three groups at both the 3and 4-mm pupil size. CONCLUSIONS: Although trifocal IOLs provided significantly better retinal image quality if influence of LOA is excluded, they also demonstrated to be the most sensitive to residual refractive errors. Both the EDOF Acrysof IQ Vivity and monofocal AcrySof SA60AT IOLs showed a comparable retinal image quality, and they are also comparable with trifocal IOLs when considering the clinically real PSF (PSF with LOA).
引用
收藏
页码:103 / +
页数:9
相关论文
共 50 条
  • [1] Optical power profiles and aberrations of a non-diffractive wavefront-shaping extended depth of focus intraocular lens
    Garzon, Nuria
    Gomez-Pedrero, Jose Antonio
    Albarran-Diego, Cesar
    Fernandez-Nunez, Sara
    Villanueva Gomez-Chacon, Sara
    Garcia-Montero, Maria
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (09) : 2897 - 2906
  • [2] Clinical Experience with a New Non-Diffractive Extended-Depth-of-Focus Intraocular Lens
    Reus, Nic J.
    Kooijman-de Groot, Marjolein J. C.
    ACTA OPHTHALMOLOGICA, 2021, 99 : 42 - 42
  • [3] Retinal Image Quality Through an Operating Microscope With Wavefront Shaping Extended Depth of Focus Intraocular Lens in Model Eye
    Inoue, Makoto
    Itoh, Yuji
    Bissen-miyajima, Hiroko
    Koto, Takashi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 265 : 117 - 126
  • [4] Polychromatic through-focus image quality in a wavefront-shaping presbyopia correcting intraocular lens
    Pastor-Pascual, Francisco
    Gomez-Gomez, Alicia
    Montes-Mico, Robert
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    EXPERT REVIEW OF OPHTHALMOLOGY, 2022, 17 (01) : 75 - 79
  • [5] Nondiffractive wavefront-shaping extended depth-of-focus intraocular lens: visual performance and patient-reported outcomes
    Kohnen, Thomas
    Petermann, Kerstin
    Boehm, Myriam
    Hemkeppler, Eva
    Ahmad, Wasim
    Hinzelmann, Lisa
    Pawlowicz, Katarzyna
    Jandewerth, Tyll
    Lwowski, Christoph
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (02): : 144 - 150
  • [6] Clinical Outcomes of a New Non-Diffractive Extended Depth-of-Focus Intraocular Lens Targeted for Mini-Monovision
    Tomagova, Nikola
    Elahi, Sina
    Vandekerckhove, Kristof
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 981 - 990
  • [7] Nondiffractive wavefront-shaping extended range-of-vision intraocular lens
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (09): : 1312 - 1313
  • [8] Evaluation of a Novel Non-Diffractive Extended Depth of Focus Intraocular Lens - First Results from a Prospective Study
    Tahmaz, Volkan
    Siebelmann, Sebastian
    Koch, Konrad R.
    Cursiefen, Claus
    Langenbucher, Achim
    Hoerster, Robert
    CURRENT EYE RESEARCH, 2022, 47 (08) : 1149 - 1155
  • [9] Comparative Study Between Non-Diffractive Extended Depth of Focus and Monofocal Intraocular Lenses
    Kandavel, Rom
    Colvard, Michael
    Dredge, Justin
    Bayle, Michael
    Alam, Tamanna
    Snyder, James
    Hall, Brad
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 1161 - 1168
  • [10] Real-world visual outcomes of a non-diffractive extended depth of focus intraocular lens implanted in Australian sites
    Mangat, Simran
    Sabel, Robyn
    Rose, Monique
    Perez-Vives, Caridad
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 51 (09): : 1015 - 1016