Point-of-care detection of glycated hemoglobin using a novel dry chemistry-based electrochemiluminescence device

被引:4
|
作者
Zhou, Xinya [1 ,2 ,3 ]
Lai, Wei [1 ,2 ,3 ]
Zhong, Jinbiao [1 ,2 ,3 ]
Yang, Yang [1 ,2 ,3 ]
Chen, Zhenyu [4 ]
Zhang, Chunsun [1 ,2 ,3 ]
机构
[1] South China Normal Univ, Coll Biophoton, MOE Key Lab Laser Life Sci, Guangzhou 510631, Peoples R China
[2] South China Normal Univ, Inst Laser Life Sci, Coll Biophoton, Guangzhou 510631, Peoples R China
[3] South China Normal Univ, Coll Biophoton, Guangdong Prov Key Lab Laser Life Sci, Guangzhou 510631, Peoples R China
[4] Guangzhou First Peoples Hosp, Nansha Hosp, Guangzhou 511457, Peoples R China
关键词
Enzyme biosensor; Dry chemistry; Three-electrode electrochemiluminescence; Point-of-care testing; Glycated hemoglobin detection; QUANTITATIVE DETECTION; LABEL-FREE; GLUCOSE; HBA1C; ELECTRODE; LUMINOL; ASSAY; IDENTIFICATION; PERFORMANCE; BIOSENSOR;
D O I
10.1016/j.aca.2023.341829
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As a good biomarker to reflect the average level of blood glucose, glycated hemoglobin (HbA1c) is mainly used for long-term glycemic monitoring and risk assessment of complications in diabetic patients. Previous analysis methods for HbA1c usually require complex pretreatment processes and large-scale biochemical analyzers, which makes it difficult to realize the point-of-care testing (POCT) of HbA1c. In this work, we have proposed a three-electrode dry chemistry-based electrochemiluminescence (ECL) biosensor and its self-contained automatic ECL analyzer. In this enzymatic biosensor, fructosyl amino-caid oxidase (FAOD) reacts with the hydrolysis product of HbA1c, and the produced hydrogen peroxide further reacts with luminol under the appropriate driving voltage, generating photons to realize the quantitative detection of HbA1c. Under optimized conditions, the biosensors have a good linear response to different concentrations of fructosyl valine (FV) ranging from 0.05 to 2 mM, with a limit of detection of 2 mu M. The within-batch variation is less than 15%, and the biosensors still have 78% of the initial response after the accelerated aging test of 36 h at 37 degrees C. Furthermore, the recoveries for different concentrations of samples in whole blood were within 92.3-99.7%. These results illustrate that the proposed method has the potential for use in POCT of HbA1c.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A dry chemistry-based electrochemiluminescence device for point-of-care testing of alanine transaminase
    Lai, Wei
    Shi, Yanyang
    Zhong, Jinbiao
    Zhou, Xinya
    Yang, Yang
    Chen, Zhenyu
    Zhang, Chunsun
    TALANTA, 2023, 256
  • [2] Dry Chemistry-Based Bipolar Electrochemiluminescence Immunoassay Device for Point-of-Care Testing of Alzheimer-Associated Neuronal Thread Protein
    Liang, Yi
    Xue, Kaifa
    Shi, Yanyang
    Zhan, Tingting
    Lai, Wei
    Zhang, Chunsun
    ANALYTICAL CHEMISTRY, 2023, 95 (06) : 3434 - 3441
  • [3] Rapid, inexpensive point-of-care device for percent Glycated Hemoglobin determinations
    Willard, D. M.
    Vickers, J.
    Wise, L.
    Morrison, M.
    Warman, J.
    Palmer, J.
    Targoff, D.
    Henry, C. S.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A198 - A198
  • [4] Evaluation of a "point-of-care" system for the determination of glycated hemoglobin
    Previtali, Giuseppe
    Amadei, Marina
    Donati, Mirella
    Frasanni, Michela
    Zurlini, Corrado
    BIOCHIMICA CLINICA, 2012, 36 (05) : 388 - 389
  • [5] PAPER BASED POINT-OF-CARE DEVICE FOR INTEGRATED ANEMIA DETECTION AND HEMOGLOBIN VARIANT IDENTIFICATION
    An, Ran
    Man, Yuncheng
    Little, Jane A.
    Gurkan, Umut A.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2020, 68 (05) : 1090 - 1090
  • [6] Integrated Point-of-Care Device for Anemia Detection and Hemoglobin Variant Identification
    An, Ran
    Hasan, Muhammad Noman
    Man, Yuncheng
    Gurkan, Umut A.
    2019 IEEE HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2019, : 37 - 40
  • [7] Novel noninvasive point-of-care device for real time hemoglobin monitoring
    Timm, Ulrich
    Gewiss, Helge
    Kraitl, Jens
    Stuepmann, Kirstin
    Hinz, Michael
    Koball, Sebastian
    Ewald, Hartmut
    OPTICAL DIAGNOSTICS AND SENSING XIV: TOWARD POINT-OF-CARE DIAGNOSTICS, 2014, 8951
  • [8] A dry chemistry-based ultrasensitive electrochemiluminescence immunosensor for sample-to-answer detection of Cardiac Troponin I
    Zhan, Tingting
    Su, Yan
    Lai, Wei
    Chen, Zhenyu
    Zhang, Chunsun
    BIOSENSORS & BIOELECTRONICS, 2022, 214
  • [9] A dry chemistry, ultrasensitive microfluidic fiber material-based immunosensor for electrochemiluminescence point-of-care testing of luteinizing hormone
    Xue, Kaifa
    Lin, Baoyu
    Huang, Shiju
    Cai, Bolin
    Lai, Wei
    Zhan, Tingting
    Liang, Yi
    Zhang, Chunsun
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 393
  • [10] INACCURACY OF POINT-OF-CARE MEASUREMENTS OF GLYCATED HEMOGLOBIN IN WELLNESS PROGRAM PARTICIPANTS
    Raymond, L. W.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2017, 65 (01) : 135 - 135