Hydraulic Performance Optimization of a Submersible Drainage Pump

被引:1
|
作者
Rakibuzzaman, Md [1 ,2 ]
Suh, Sang-Ho [3 ]
Roh, Hyung-Woon [4 ]
Song, Kyung Hee [5 ]
Song, Kwang Chul [5 ]
Zhou, Ling [1 ]
机构
[1] Jiangsu Univ, Natl Res Ctr Pumps, Zhenjiang 212013, Peoples R China
[2] Int Univ Business Agr & Technol, Dept Mech Engn, Dhaka 1230, Bangladesh
[3] Soongsil Univ, Sch Mech Engn, Seoul 06978, South Korea
[4] IVAI Ltd, Seoul 157754, South Korea
[5] Daeyoung Power Pump, Hwaseong 445861, Gyoenggi Do, South Korea
关键词
submersible pump; computational fluid dynamics; experiment; impeller shape; flow balance block; optimum model; OPTIMAL-DESIGN; EFFICIENCY; IMPELLER;
D O I
10.3390/computation12010012
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
Small submersible drainage pumps are used to discharge leaking water and rainwater in buildings. In an emergency (e.g., heavy rain or accident), advance monitoring of the flow rate is essential to enable optimal operation, considering the point where the pump operates abnormally when the water level is increased rapidly. Moreover, pump performance optimization is crucial for energy-saving policy. Therefore, it is necessary to meet the challenges of submersible pump systems, including sustainability and pump efficiency. The final goal of this study was to develop an energy-saving and highly efficient submersible drainage pump capable of performing efficiently in emergencies. In particular, this paper targeted the hydraulic performance improvement of a submersible drainage pump model. Prior to the development of driving-mode-related technology capable of emergency response, a way to improve the performance characteristics of the existing submersible drainage pump was found. Disassembling of the current pump followed by reverse engineering was performed instead of designing a new pump. Numerical simulation was performed to analyze the flow characteristics and pump efficiency. An experiment was carried out to obtain the performance, and it was validated with numerical results. The results reveal that changing the cross-sectional shape of the impeller reduced the flow separation and enhanced velocity and pressure distributions. Also, it reduced the power and increased efficiency. The results also show that the pump's efficiency was increased to 5.56% at a discharge rate of 0.17 m3/min, and overall average efficiency was increased to 6.53%. It was concluded that the submersible pump design method is suitable for the numerical designing of an optimized pump's impeller and casing. This paper provides insight on the design optimization of pumps.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] The Optimization Method of Variable Frequency Control of Electric Submersible Pump
    Zhang, Jinxin
    Zhang, Qing
    Pang, Litao
    Li, Xiubin
    [J]. INTERNATIONAL CONFERENCE ON MATERIALS PROCESSING AND MECHANICAL MANUFACTURING ENGINEERING (MPMME 2015), 2015, : 99 - 103
  • [32] Research on Optimization of Nozzle Scheduling Scheme for Electric Submersible Pump
    Dong, Shi-Min
    Wang, Hong-Bo
    Zhao, Ran
    Hou, Tian-Bo-Wen
    [J]. 2015 INTERNATIONAL CONFERENCE ON MECHANICAL SCIENCE AND MECHANICAL DESIGN, MSMD 2015, 2015, : 125 - 136
  • [33] Kriging based multi-objective optimization for hydraulic performance of centrifugal pump
    Zhang, Yu
    Qin, Gang
    Zhang, Yunqing
    Chen, Lipin
    [J]. Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2015, 43 (04): : 54 - 57
  • [34] Multiobjective optimization of a tubular pump to improve the applicable operating head and hydraulic performance
    Zhao, Wenlong
    Zhang, Jian
    Yu, Xiaodong
    Zhou, Daqing
    Calamak, Melih
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2021, 235 (09) : 1555 - 1566
  • [35] Optimization of the hydraulic performance of a centrifugal pump impeller based on the blade load distribution
    Key Laboratory of Thermal Fluid Science and Engineering of MOE, Xi'an Jiaotong University, Xi'an
    710049, China
    [J]. Harbin Gongcheng Daxue Xuebao, 4 (505-510):
  • [36] INTERACTIONAL EFFECTS OF INLET GUIDE VANE AND BLADE ANGLE ON HYDRAULIC PERFORMANCE CHARACTERISTICS OF A SUBMERSIBLE AXIAL-FLOW PUMP
    Kim, Youn-Sung
    Shim, Hyeon-Seok
    Kim, Kwang-Yong
    [J]. PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2018, VOL 3, 2018,
  • [37] Study and application of the thermal effect of deep pumping technology for the combination of hydraulic jet pump and electric submersible pump
    [J]. Shi You Zuan Cai Gong Yi/Oil Drilling and Production Technology, 20 (01): : 62 - 65
  • [38] Performance evaluation of a transformerless multiphase electric submersible pump system
    Hakeem, Ahmed A.
    Elserougi, Ahmed Abbas
    Abdel-Khalik, Ayman Samy
    Ahmed, Shehab
    Massoud, Ahmed Mohamed
    [J]. JOURNAL OF ENGINEERING-JOE, 2014, Institution of Engineering and Technology, United States (2014):
  • [39] The effect of twin volutes on the flow and radial hydraulic force production in a submersible centrifugal pump
    Kang, Can
    Li, Yunxiao
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2015, 229 (02) : 221 - 237
  • [40] NUMERICAL STUDY OF THE INFLUENCE OF VISCOSITY ON THE PERFORMANCE OF AN ELECTRICAL SUBMERSIBLE PUMP
    Sirino, Thiago
    Stel, Henrique
    Morales, Rigoberto E. M.
    [J]. PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2013, VOL 1B: SYMPOSIA, 2014,