Hydraulic Performance Optimization of a Submersible Drainage Pump

被引:1
|
作者
Rakibuzzaman, Md [1 ,2 ]
Suh, Sang-Ho [3 ]
Roh, Hyung-Woon [4 ]
Song, Kyung Hee [5 ]
Song, Kwang Chul [5 ]
Zhou, Ling [1 ]
机构
[1] Jiangsu Univ, Natl Res Ctr Pumps, Zhenjiang 212013, Peoples R China
[2] Int Univ Business Agr & Technol, Dept Mech Engn, Dhaka 1230, Bangladesh
[3] Soongsil Univ, Sch Mech Engn, Seoul 06978, South Korea
[4] IVAI Ltd, Seoul 157754, South Korea
[5] Daeyoung Power Pump, Hwaseong 445861, Gyoenggi Do, South Korea
关键词
submersible pump; computational fluid dynamics; experiment; impeller shape; flow balance block; optimum model; OPTIMAL-DESIGN; EFFICIENCY; IMPELLER;
D O I
10.3390/computation12010012
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
Small submersible drainage pumps are used to discharge leaking water and rainwater in buildings. In an emergency (e.g., heavy rain or accident), advance monitoring of the flow rate is essential to enable optimal operation, considering the point where the pump operates abnormally when the water level is increased rapidly. Moreover, pump performance optimization is crucial for energy-saving policy. Therefore, it is necessary to meet the challenges of submersible pump systems, including sustainability and pump efficiency. The final goal of this study was to develop an energy-saving and highly efficient submersible drainage pump capable of performing efficiently in emergencies. In particular, this paper targeted the hydraulic performance improvement of a submersible drainage pump model. Prior to the development of driving-mode-related technology capable of emergency response, a way to improve the performance characteristics of the existing submersible drainage pump was found. Disassembling of the current pump followed by reverse engineering was performed instead of designing a new pump. Numerical simulation was performed to analyze the flow characteristics and pump efficiency. An experiment was carried out to obtain the performance, and it was validated with numerical results. The results reveal that changing the cross-sectional shape of the impeller reduced the flow separation and enhanced velocity and pressure distributions. Also, it reduced the power and increased efficiency. The results also show that the pump's efficiency was increased to 5.56% at a discharge rate of 0.17 m3/min, and overall average efficiency was increased to 6.53%. It was concluded that the submersible pump design method is suitable for the numerical designing of an optimized pump's impeller and casing. This paper provides insight on the design optimization of pumps.
引用
收藏
页数:16
相关论文
共 50 条
  • [2] Field operation and performance of a downhole hydraulic submersible multiphase pump
    Harden, WG
    [J]. FLUID MACHINERY FOR THE OIL, GAS, AND PETROCHEMICAL INDUSTRY, 2003, 2003 (01): : 105 - 116
  • [3] The Influence of Bulb Position on Hydraulic Performance of Submersible Tubular Pump Device
    Sun, Zhuangzhuang
    Yu, Jie
    Tang, Fangping
    [J]. JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2021, 9 (08)
  • [4] Hydraulic performance of the bidirectional submersible tubular pump with adjustable guide vanes
    Sun Z.
    Yu J.
    Ge H.
    Yuan H.
    Tang F.
    [J]. Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2022, 38 (04): : 42 - 50
  • [5] Numerical Simulation and Performance Prediction for Hydraulic Performance of Mine Drainage Pump
    Li, Baoliang
    Yan, Zhishun
    Hu, Xiaowei
    [J]. MECHANICAL ENGINEERING, MATERIALS AND ENERGY II, 2013, 281 : 216 - 220
  • [6] Field trial of a novel multiphase hydraulic submersible pump
    不详
    [J]. JOURNAL OF PETROLEUM TECHNOLOGY, 2001, 53 (10): : 33 - +
  • [7] Development of a gas-handling hydraulic submersible pump
    不详
    [J]. JOURNAL OF PETROLEUM TECHNOLOGY, 1997, 49 (07): : 741 - &
  • [8] Field trial of a novel multiphase hydraulic submersible pump
    Harden, W.G.
    Downie, A.A.
    [J]. JPT, Journal of Petroleum Technology, 2001, 52 (10): : 33 - 37
  • [9] Field trial of a novel multiphase hydraulic submersible pump
    [J]. 1600, (Society of Petroleum Engineers (SPE)):
  • [10] PERFORMANCE ENHANCEMENT OF AN ELECTRIC SUBMERSIBLE PUMP
    Adhav, Rohit S.
    Samad, Abdus
    Kenyery, Frank
    [J]. PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2014, 2014,