Robotic Needle Insertion With 2D Ultrasound–3D CT Fusion Guidance

被引:1
|
作者
Lei, Long [1 ,2 ]
Zhao, Baoliang [1 ]
Qi, Xiaozhi [1 ]
Mi, Rui [3 ]
Ye, Hai [3 ]
Zhang, Peng [1 ]
Wang, Qiong [1 ]
Heng, Pheng-Ann [4 ,5 ]
Hu, Ying [1 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[2] Chinese Univ Hong Kong, Dept Comp Sci & Engn, Hong Kong, Peoples R China
[3] Shenzhen Univ, Gen Hosp, Clin Med Acad, Dept Radiol, Shenzhen 518055, Peoples R China
[4] Chinese Univ Hong Kong, Dept Comp Sci & Engn, Hong Kong, Peoples R China
[5] Chinese Univ Hong Kong, Guangdong Hong Kong Macao Joint Lab Human Machine, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Percutaneous puncture; puncture robot; respiratory motion; ultrasound-CT registration; ultrasound probe calibration; IMAGE REGISTRATION; FLEXIBLE NEEDLE; LIVER-TUMORS; ULTRASOUND; MOTION; ACCURACY; ABLATION; TOOLKIT; SYSTEM;
D O I
10.1109/TASE.2023.3322710
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Puncture robots pave a new way for stable, accurate and safe percutaneous liver tumor puncture operation. However, affected by respiratory motion, intraoperative accurate location of the tumor and its surrounding anatomical structures remains a difficult problem in existing robot-assisted puncture operations. In this paper, a dual-arm robotic needle insertion system with guidance of intraoperative 2D ultrasound (US) and preoperative 3D computed tomography (CT) fusion is proposed, addressing the shortcomings of existing puncture robots. To deal with the challenge of cross-modal and cross-dimensional registration between 2D US and 3D CT, a decoupled two-stage registration approach combining initial vessel structure-based 3D US - 3D CT registration with intraoperative intensity-based 2D US -3D US registration is proposed. To achieve fast and robust ultrasound probe calibration, a method based on an improved N-wire phantom is proposed. Twenty puncture experiments are performed in different breath-holding positions on a respiratory motion simulation platform, and experimental results show that the mean puncture error is 2.48 mm, which can meet the requirements in a wide of clinical scenarios Note to Practitioners-In clinical percutaneous liver tumor puncture operation, due to the lack of real-time and clear image guidance, it is difficult to locate the tumor and its surrounding vital anatomical structures. In addition, the stability and accuracy of manual operation are poor. The development of a puncture robot is an effective solution for these problems. However, existing CT and magnetic resonance imaging (MRI) guided robots do not consider the tumor localization errors caused by inconsistent breath-holding positions between preoperative scan period and intraoperative puncture period, and US guided robots are limited by the poor image quality and the narrow field of vision. In this paper, a dual-arm robotic needle insertion system with guidance of intraoperative 2D US and preoperative 3D CT fusion is proposed. This system can take advantage of the real-time ultrasound and clear CT images at the same time, and can provide real-time, clear and all-round guidance for percutaneous liver tumor puncture operation, which has obvious advantages over the existing puncture robots. Phantom experiments have been completed and animal experiments will be carried out in the future.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [31] Volumetric CT scanning: 2D and 3D reconstruction
    Ferretti, G. -R.
    Jankowski, A.
    [J]. REVUE DES MALADIES RESPIRATOIRES, 2010, 27 (10) : 1267 - 1274
  • [32] An approach to 2D/3D registration of a vertebra in 2D x-ray fluoroscopies with 3D CT images
    Weese, J
    Buzug, TM
    Lorenz, C
    Fassnacht, C
    [J]. CVRMED-MRCAS'97: FIRST JOINT CONFERENCE - COMPUTER VISION, VIRTUAL REALITY AND ROBOTICS IN MEDICINE AND MEDICAL ROBOTICS AND COMPUTER-ASSISTED SURGERY, 1997, 1205 : 119 - 128
  • [33] Needle Insertion Study Using Ultrasound-Based 2D Motion Tracking
    Dehghan, Ehsan
    Salcudean, Septimiu E.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 660 - 667
  • [34] Rigid Registration of Untracked Freehand 2D Ultrasound Sweeps to 3D CT of Liver Tumours
    Cifor, Amalia
    Risser, Laurent
    Heinrich, Mattias P.
    Chung, Daniel
    Schnabel, Julia A.
    [J]. ABDOMINAL IMAGING: COMPUTATION AND CLINICAL APPLICATIONS, 2013, 8198 : 155 - 164
  • [35] Modeling bone resorption in 2D CT and 3D μCT images
    Zaikin, A
    Kurths, J
    Saparin, P
    Gowin, W
    Prohaska, S
    [J]. INTERNATIONAL JOURNAL OF BIFURCATION AND CHAOS, 2005, 15 (09): : 2995 - 3009
  • [36] 2D or 3D?
    Mills, R
    [J]. COMPUTER-AIDED ENGINEERING, 1996, 15 (08): : 4 - 4
  • [37] Semantic Scene Completion With 2D and 3D Feature Fusion
    Park, Sang-Min
    Ha, Jong-Eun
    [J]. IEEE Access, 2024, 12 : 141594 - 141603
  • [38] Face recognition based on 2D and 3D data fusion
    Krotewicz, Pawel
    Sankowski, Wojciech
    Nowak, Piotr Stefan
    [J]. INTERNATIONAL JOURNAL OF BIOMETRICS, 2015, 7 (01) : 69 - 81
  • [39] 2D and 3D Palmprint Extraction by an Automated Ultrasound System
    Iula, Antonio
    Hine, Gabriel
    Ramalli, Alessandro
    Guidi, Francesco
    Boni, Enrico
    [J]. APPLICATIONS IN ELECTRONICS PERVADING INDUSTRY, ENVIRONMENT AND SOCIETY, APPLEPIES 2014, 2016, 351 : 83 - 89
  • [40] Data fusion in 2D and 3D image processing: An overview
    Bloch, I
    Maitre, H
    [J]. X BRAZILIAN SYMPOSIUM ON COMPUTER GRAPHICS AND IMAGE PROCESSING, PROCEEDINGS, 1997, : 127 - 134