Cross-scanner harmonization methods for structural MRI may need further work: A comparison study

被引:13
|
作者
Gebre, Robel K. [1 ,5 ]
Senjem, Matthew L. [1 ,2 ]
Raghavan, Sheelakumari [1 ]
Schwarz, Christopher G. [1 ]
Gunter, Jeffery L. [1 ]
Hofrenning, Ekaterina I. [3 ]
Reid, Robert I. [2 ]
Kantarci, Kejal [1 ]
Graff-Radford, Jonathan [4 ]
Knopman, David S. [4 ]
Petersen, Ronald C. [4 ]
Jack Jr, Clifford R. [1 ]
Vemuri, Prashanthi [1 ,5 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Informat Technol, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Quantitat Hlth Sci, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Neurol, Rochester, MN 55905 USA
[5] Mayo Clin & Mayo Fdn, 200 First St SW, Rochester, MN 55905 USA
关键词
Deep learning; Structural MRI; Scan harmonization; CORTICAL THICKNESS;
D O I
10.1016/j.neuroimage.2023.119912
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The clinical usefulness MRI biomarkers for aging and dementia studies relies on precise brain morphological mea-surements; however, scanner and/or protocol variations may introduce noise or bias. One approach to address this is post-acquisition scan harmonization. In this work, we evaluate deep learning (neural style transfer, Cycle-GAN and CGAN), histogram matching, and statistical (ComBat and LongComBat) methods. Participants who had been scanned on both GE and Siemens scanners (cross-sectional participants, known as Crossover (n = 113), and longitudinally scanned participants on both scanners (n = 454)) were used. The goal was to match GE MPRAGE (T1-weighted) scans to Siemens improved resolution MPRAGE scans. Harmonization was performed on raw native and preprocessed (resampled, affine transformed to template space) scans. Cortical thicknesses were measured using FreeSurfer (v.7.1.1). Distributions were checked using Kolmogorov-Smirnov tests. Intra-class correlation (ICC) was used to assess the degree of agreement in the Crossover datasets and annualized percent change in cor-tical thickness was calculated to evaluate the Longitudinal datasets. Prior to harmonization, the least agreement was found at the frontal pole (ICC = 0.72) for the raw native scans, and at caudal anterior cingulate (0.76) and frontal pole (0.54) for the preprocessed scans. Harmonization with NST, CycleGAN, and HM improved the ICCs of the preprocessed scans at the caudal anterior cingulate ( > 0.81) and frontal poles ( > 0.67). In the Longitudinal raw native scans, over-and under-estimations of cortical thickness were observed due to the changing of the scanners. ComBat matched the cortical thickness distributions throughout but was not able to increase the ICCs or remove the effects of scanner changeover in the Longitudinal datasets. CycleGAN and NST performed slightly better to address the cortical thickness variations between scanner change. However, none of the methods suc-ceeded in harmonizing the Longitudinal dataset. CGAN was the worst performer for both datasets. In conclusion, the performance of the methods was overall similar and region dependent. Future research is needed to improve the existing approaches since none of them outperformed each other in terms of harmonizing the datasets at all ROIs. The findings of this study establish framework for future research into the scan harmonization problem.
引用
收藏
页数:11
相关论文
共 7 条
  • [1] Cross-Scanner Harmonization of Neuromelanin-Sensitive MRI for Multisite Studies
    Wengler, Kenneth
    Cassidy, Clifford
    van Der Pluijm, Marieke
    Weinstein, Jodi J.
    Abi-Dargham, Anissa
    van de Giessen, Elsmarieke
    Horga, Guillermo
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (04) : 1189 - 1199
  • [2] Editorial for "Cross-Scanner Harmonization of Neuromelanin-Sensitive MRI for Multisite Studies"
    Wieland, Lara
    Schlagenhauf, Florian
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (05) : 1584 - 1585
  • [3] Cross-scanner reproducibility and harmonization of a diffusion MRI structural brain network: A traveling subject study of multi-b acquisition
    Kurokawa, Ryo
    Kamiya, Kouhei
    Koike, Shinsuke
    Nakaya, Moto
    Uematsu, Akiko
    Tanaka, Saori C.
    Kamagata, Koji
    Okada, Naohiro
    Morita, Kentaro
    Kasai, Kiyoto
    Abe, Osamu
    [J]. NEUROIMAGE, 2021, 245
  • [4] Cross-Scanner Harmonization of Neuromelanin-Sensitive MRI for Multi-Site Studies
    Wengler, Kenneth
    Cassidy, Clifford
    van der Pluijm, Marieke
    Weinstein, Jodi
    Abi-Dargham, Anissa
    van de Giessen, Elsmarieke
    Horga, Guillermo
    [J]. BIOLOGICAL PSYCHIATRY, 2021, 89 (09) : S356 - S356
  • [5] Cross-scanner and cross-protocol multi-shell diffusion MRI data harmonization: Algorithms and results
    Ning, Lipeng
    Bonet-Carne, Elisenda
    Grussu, Francesco
    Sepehrband, Farshid
    Kaden, Enrico
    Veraart, Jelle
    Blumberg, Stefano B.
    Khoo, Can Son
    Palombo, Marco
    Kokkinos, Iasonas
    Alexander, Daniel C.
    Coll-Font, Jaume
    Scherrer, Benoit
    Warfield, Simon K.
    Karayumak, Suheyla Cetin
    Rathi, Yogesh
    Koppers, Simon
    Weninger, Leon
    Ebert, Julia
    Merhof, Dorit
    Moyer, Daniel
    Pietsch, Maximilian
    Christiaens, Daan
    Teixeira, Rui Azeredo Gomes
    Tournier, Jacques-Donald
    Schilling, Kurt G.
    Huo, Yuankai
    Nath, Vishwesh
    Hansen, Colin
    Blaber, Justin
    Landman, Bennett A.
    Zhylka, Andrey
    Pluim, Josien P. W.
    Parker, Greg
    Rudrapatna, Umesh
    Evans, John
    Charron, Cyril
    Jones, Derek K.
    Tax, Chantal M. W.
    [J]. NEUROIMAGE, 2020, 221
  • [6] COMPARISON OF 2 METHODS OF COLD WORK TO INCREASE STRENGTH OF HOT ROLLED REINFORCING BAR - A FURTHER STUDY
    PUSSEGODA, LN
    SUMANASIRI, KED
    [J]. CANADIAN METALLURGICAL QUARTERLY, 1988, 27 (03) : 197 - 203
  • [7] A comparison of 18F-FDG PET-based radiomics and deep learning in predicting regional lymph node metastasis in patients with resectable lung adenocarcinoma: a cross-scanner and temporal validation study
    Lue, Kun-Han
    Chen, Yu-Hung
    Chu, Sung-Chao
    Chang, Bee-Song
    Lin, Chih-Bin
    Chen, Yen-Chang
    Lin, Hsin-Hon
    Liu, Shu-Hsin
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (12) : 1094 - 1105