Deep learning for myocardial ischemia auxiliary diagnosis using CZT SPECT myocardial perfusion imaging

被引:2
|
作者
Su, Ting-Yi [1 ]
Chen, Jui-Jen [2 ]
Chen, Wei-Shiang [1 ]
Chang, Yen-Hsiang [2 ,3 ]
Lu, Henry Horng-Shing [1 ,4 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Inst Stat, Hsinchu, Taiwan
[2] Chang Gung Univ, Chang Gung Mem Hosp, Kaohsiung Med Ctr, Dept Nucl Med,Coll Med, Kaohsiung, Taiwan
[3] Chang Gung Univ, Chang Gung Mem Hosp, Kaohsiung Med Ctr, Dept Nucl Med,Coll Med, 123,DAPI Rd, Kaohsiung 833, Taiwan
[4] Natl Yang Ming Chiao Tung Univ, Inst Stat, 1001,Univ Rd, Hsinchu 300, Taiwan
关键词
Cardiovascular diseases; Convolutional neural network; Machine learning; Myocardial perfusion image; COMPUTED-TOMOGRAPHY;
D O I
10.1097/JCMA.0000000000000833
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:The World Health Organization reported that cardiovascular disease is the most common cause of death worldwide. On average, one person dies of heart disease every 26 min worldwide. Deep learning approaches are characterized by the appropriate combination of abnormal features based on numerous annotated images. The constructed convolutional neural network (CNN) model can identify normal states of reversible and irreversible myocardial defects and alert physicians for further diagnosis. Methods:Cadmium zinc telluride single-photon emission computed tomography myocardial perfusion resting-state images were collected at Chang Gung Memorial Hospital, Kaohsiung Medical Center, Kaohsiung, Taiwan, and were analyzed with a deep learning convolutional neural network to classify myocardial perfusion images for coronary heart diseases. Results:In these grey-scale images, the heart blood flow distribution was the most crucial feature. The deep learning technique of You Only Look Once was used to determine the myocardial defect area and crop the images. After surrounding noise had been eliminated, a three-dimensional CNN model was used to identify patients with coronary heart diseases. The prediction area under the curve, accuracy, sensitivity, and specificity was 90.97, 87.08, 86.49, and 87.41%, respectively. Conclusion:Our prototype system can considerably reduce the time required for image interpretation and improve the quality of medical care. It can assist clinical experts by offering accurate coronary heart disease diagnosis in practice.
引用
收藏
页码:122 / 130
页数:9
相关论文
共 50 条
  • [41] Low dose thallium myocardial perfusion imaging using CZT camera
    Kincl, V.
    Kaminek, M.
    Vasina, J.
    Havel, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S557 - S557
  • [42] Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using CZT-SPECT
    van Dijk, J. D.
    Jager, P. L.
    Mouden, M.
    Slump, C. H.
    Ottervanger, J. P.
    Oostdijk, A. H. J.
    de Boer, J.
    van Dalen, J. A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S247 - S247
  • [43] Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using CZT-SPECT
    J. D. van Dijk
    P. L. Jager
    M. Mouden
    C. H. Slump
    J. P. Ottervanger
    J. de Boer
    A. H. J. Oostdijk
    J. A. van Dalen
    [J]. Journal of Nuclear Cardiology, 2014, 21 : 1158 - 1167
  • [44] Comparison of the prognostic value of myocardial perfusion imaging using a CZT-SPECT camera with a conventional anger camera
    Lima, Ronaldo
    Peclat, Thais
    Soares, Thalita
    Ferreira, Caio
    Souza, Ana Carolina
    Camargo, Gabriel
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (01) : 245 - 251
  • [45] Value of respiratory and patient motion correction in myocardial perfusion imaging using a CZT-based SPECT camera
    Van Dijk, Joris
    Dalen, Jorn
    Mouden, Mohamed
    Ottervanger, Jan Paul
    Knollema, Siert
    Slump, Cornelis
    Jager, Pieter
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [46] Comparison of the prognostic value of myocardial perfusion imaging using a CZT-SPECT camera with a conventional anger camera
    Ronaldo Lima
    Thais Peclat
    Thalita Soares
    Caio Ferreira
    Ana Carolina Souza
    Gabriel Camargo
    [J]. Journal of Nuclear Cardiology, 2017, 24 : 245 - 251
  • [47] Quantification of Spect myocardial perfusion imaging
    Wanda Acampa
    Wei He
    Carmine di Nuzzo
    Alberto Cuocolo
    [J]. Journal of Nuclear Cardiology, 2002, 9 : 338 - 342
  • [48] SPECT myocardial perfusion imaging as an endpoint
    Melody Sherwood
    Fadi G. Hage
    Jack Heo
    Leslee J. Shaw
    Manuel D. Cerqueira
    Ami E. Iskandrian
    [J]. Journal of Nuclear Cardiology, 2012, 19 : 891 - 894
  • [49] Quantification of SPECT myocardial perfusion imaging
    Acampa, W
    He, W
    di Nuzzo, C
    Cuocolo, A
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (03) : 338 - 342
  • [50] SPECT MYOCARDIAL PERFUSION IMAGING UPDATE
    DATZ, FL
    GULLBERG, G
    GABOR, FV
    MORTON, KA
    [J]. SEMINARS IN ULTRASOUND CT AND MRI, 1991, 12 (01) : 28 - 44