Total-Body Perfusion Imaging with [11C]-Butanol

被引:9
|
作者
Li, Elizabeth J. [1 ]
Lopez, Javier E. [2 ]
Spencer, Benjamin A. [1 ]
Abdelhafez, Yasser [3 ]
Badawi, Ramsey D. [1 ,3 ]
Wang, Guobao [3 ]
Cherry, Simon R. [1 ,3 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] UC Davis Hlth, Dept Internal Med, Div Cardiovasc Med, Sacramento, CA USA
[3] Univ Calif Davis, UC Davis Hlth, Dept Radiol, Sacramento, CA 95817 USA
关键词
Key Words; dynamic PET; kinetic modeling; perfusion and blood flow; 11C]-butanol; total-body PET; CEREBRAL-BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; DYNAMIC PET; TIME-DELAY; VOLUME; WATER; QUANTIFICATION; PERMEABILITY; INHALATION; FRACTION;
D O I
10.2967/jnumed.123.265659
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tissue perfusion can be affected by physiology or disease. With the advent of total-body PET, quantitative measurement of perfusion across the entire body is possible. [11C]-butanol is a perfusion tracer with a superior extraction fraction compared with [15O]-water and [13N]-ammonia. To develop the methodology for total-body perfusion imaging, a pilot study using [11C]-butanol on the uEXPLORER total -body PET/CT scanner was conducted.Methods: Eight participants (6 healthy volunteers and 2 patients with peripheral vascular disease [PVD]) were injected with a bolus of [11C]-butanol and underwent 30-min dynamic acquisitions. Three healthy volunteers underwent repeat studies at rest (baseline) to assess test-retest reproducibility; 1 volunteer underwent paired rest and cold pressor test (CPT) studies. Changes in perfusion were measured in the paired rest-CPT study. For PVD patients, local changes in perfusion were investigated and correlated with patient medical history. Regional and parametric kinetic analysis methods were developed using a 1-tissue compartment model and leading-edge delay correction.Results: Estimated baseline perfusion values ranged from 0.02 to 1.95 mL center dot min-1 center dot cm-3 across organs. Test-retest analysis showed that repeat baseline per-fusion measurements were highly correlated (slope, 0.99; Pearson r 5 0.96, P , 0.001). For the CPT subject, the largest regional increases were in skeletal muscle (psoas, 142%) and the myocardium (64%). One of the PVD patients showed increased collateral vessel growth in the calf because of a peripheral stenosis. Comorbidities including myocardial infarction, hypothyroidism, and renal failure were correlated with variations in organ-specific perfusion.Conclusion: This pilot study demonstrates the ability to obtain reproducible mea-surements of total-body perfusion using [11C]-butanol. The methods are sensitive to local perturbations in flow because of physiologic stressors and disease.
引用
收藏
页码:1831 / 1838
页数:8
相关论文
共 50 条
  • [41] TOTAL-BODY WATER AND TOTAL-BODY POTASSIUM IN ANOREXIA-NERVOSA
    DEMPSEY, DT
    CROSBY, LO
    LUSK, E
    OBERLANDER, JL
    PERTSCHUK, MJ
    MULLEN, JL
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1984, 40 (02): : 260 - 269
  • [42] TOTAL-BODY WATER AND TOTAL-BODY POTASSIUM IN PATIENTS WITH CONTINENT ILEOSTOMIES
    NILSSON, LO
    ANDERSSON, H
    BOSAEUS, I
    MYRVOLD, HE
    GUT, 1982, 23 (07) : 589 - 593
  • [43] Imaging of adrenocortical metastases with [11C]metomidate
    Mitterhauser, Markus
    Dobrozemsky, Georg
    Zettinig, Georg
    Wadsak, Wolfgang
    Vierhapper, Heinrich
    Dudczak, Robert
    Kletter, Kurt
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (08) : 974 - 974
  • [44] Myelin imaging with [11C]MeDAS PET
    van der Weijden, C. W. J.
    Meilof, J. F.
    Dierckx, R. A. J. O.
    de Vries, E. F. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S445 - S445
  • [45] PET imaging of focal demyelination and remyelination in a rat model of multiple sclerosis: comparison of [11C]MeDAS, [11C]CIC and [11C]PIB
    Daniele de Paula Faria
    Sjef Copray
    Jurgen W. A. Sijbesma
    Antoon T. M. Willemsen
    Carlos A. Buchpiguel
    Rudi A. J. O. Dierckx
    Erik F. J. de Vries
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 995 - 1003
  • [46] Imaging of adrenocortical metastases with [11C]metomidate
    Markus Mitterhauser
    Georg Dobrozemsky
    Georg Zettinig
    Wolfgang Wadsak
    Heinrich Vierhapper
    Robert Dudczak
    Kurt Kletter
    European Journal of Nuclear Medicine and Molecular Imaging, 2006, 33 : 974 - 974
  • [47] PET imaging of focal demyelination and remyelination in a rat model of multiple sclerosis: comparison of [11C]MeDAS, [11C]CIC and [11C]PIB
    Faria, Daniele de Paula
    Copray, Sjef
    Sijbesma, Jurgen W. A.
    Willemsen, Antoon T. M.
    Buchpiguel, Carlos A.
    Dierckx, Rudi A. J. O.
    de Vries, Erik F. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (05) : 995 - 1003
  • [48] Fully Automated Radiosynthesis of [11C]Guanidines and Bioevaluation of [11C]PHPOG as Cardiac Imaging Agent
    Zhao, Austin
    Brooks, Allen
    Raffel, David
    Scott, Peter
    Shao, Xia
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [49] A TOTAL-BODY IRRADIATOR
    BRUCER, M
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1961, 10 (2-3): : 99 - &
  • [50] TOTAL-BODY COUNTING
    HELGESON, GL
    HEALTH PHYSICS, 1973, 25 (03): : 303 - 303