Total-Body Perfusion Imaging with [11C]-Butanol

被引:9
|
作者
Li, Elizabeth J. [1 ]
Lopez, Javier E. [2 ]
Spencer, Benjamin A. [1 ]
Abdelhafez, Yasser [3 ]
Badawi, Ramsey D. [1 ,3 ]
Wang, Guobao [3 ]
Cherry, Simon R. [1 ,3 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] UC Davis Hlth, Dept Internal Med, Div Cardiovasc Med, Sacramento, CA USA
[3] Univ Calif Davis, UC Davis Hlth, Dept Radiol, Sacramento, CA 95817 USA
关键词
Key Words; dynamic PET; kinetic modeling; perfusion and blood flow; 11C]-butanol; total-body PET; CEREBRAL-BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; DYNAMIC PET; TIME-DELAY; VOLUME; WATER; QUANTIFICATION; PERMEABILITY; INHALATION; FRACTION;
D O I
10.2967/jnumed.123.265659
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tissue perfusion can be affected by physiology or disease. With the advent of total-body PET, quantitative measurement of perfusion across the entire body is possible. [11C]-butanol is a perfusion tracer with a superior extraction fraction compared with [15O]-water and [13N]-ammonia. To develop the methodology for total-body perfusion imaging, a pilot study using [11C]-butanol on the uEXPLORER total -body PET/CT scanner was conducted.Methods: Eight participants (6 healthy volunteers and 2 patients with peripheral vascular disease [PVD]) were injected with a bolus of [11C]-butanol and underwent 30-min dynamic acquisitions. Three healthy volunteers underwent repeat studies at rest (baseline) to assess test-retest reproducibility; 1 volunteer underwent paired rest and cold pressor test (CPT) studies. Changes in perfusion were measured in the paired rest-CPT study. For PVD patients, local changes in perfusion were investigated and correlated with patient medical history. Regional and parametric kinetic analysis methods were developed using a 1-tissue compartment model and leading-edge delay correction.Results: Estimated baseline perfusion values ranged from 0.02 to 1.95 mL center dot min-1 center dot cm-3 across organs. Test-retest analysis showed that repeat baseline per-fusion measurements were highly correlated (slope, 0.99; Pearson r 5 0.96, P , 0.001). For the CPT subject, the largest regional increases were in skeletal muscle (psoas, 142%) and the myocardium (64%). One of the PVD patients showed increased collateral vessel growth in the calf because of a peripheral stenosis. Comorbidities including myocardial infarction, hypothyroidism, and renal failure were correlated with variations in organ-specific perfusion.Conclusion: This pilot study demonstrates the ability to obtain reproducible mea-surements of total-body perfusion using [11C]-butanol. The methods are sensitive to local perturbations in flow because of physiologic stressors and disease.
引用
收藏
页码:1831 / 1838
页数:8
相关论文
共 50 条
  • [1] Quantitative Perfusion Imaging with Total-Body PET
    Knuuti, Juhani
    Tuisku, Jouni
    Karpijoki, Henri
    Iida, Hidehiro
    Maaniitty, Teemu
    Latva-Rasku, Aino
    Oikonen, Vesa
    Nesterov, Sergey V.
    Teuho, Jarmo
    Jaakkola, Maria K.
    Klen, Riku
    Louhi, Heli
    Saunavaara, Virva
    Nuutila, Pirjo
    Saraste, Antti
    Rinne, Juha
    Nummenmaa, Lauri
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64 : 11S - 19S
  • [2] Total-body imaging of mu-opioid receptors with [11C]carfentanil in non-human primates
    Hsieh, Chia-Ju
    Hou, Catherine
    Lee, Hsiaoju
    Tomita, Cosette
    Schmitz, Alexander
    Plakas, Konstantinos
    Dubroff, Jacob G.
    Mach, Robert H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 (11) : 3273 - 3283
  • [3] Early dynamic and delayed total-body [11C]choline PET tumor imaging in patients with bladder cancer
    Liu, Chen
    Wang, Shuo
    Wu, Runze
    Zhou, Yun
    Xie, Qing
    Liu, Teli
    Yang, Yong
    Du, Peng
    Yang, Zhi
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [4] TOTAL-BODY PERFUSION
    KLEBANOFF, G
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1972, 220 (11) : 1495 - +
  • [5] Dynamic characteristics of ureteral cancer with [11C]choline total-body PET/CT
    Liu, C.
    Wang, S.
    Wu, R.
    Xie, Q.
    Yang, Y.
    Yang, Z.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S637 - S637
  • [6] Metabolic kinetic modeling of [11C]methionine based on total-body PET in multiple myeloma
    Li, Jiajin
    Ni, Beiwen
    Yu, Xiaofeng
    Wang, Cheng
    Li, Lianghua
    Zhou, Yun
    Gu, Yue
    Huang, Gang
    Hou, Jian
    Liu, Jianjun
    Chen, Yumei
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (09) : 2683 - 2691
  • [7] Metabolic kinetic modeling of [11C]methionine based on total-body PET in multiple myeloma
    Jiajin Li
    Beiwen Ni
    Xiaofeng Yu
    Cheng Wang
    Lianghua Li
    Yun Zhou
    Yue Gu
    Gang Huang
    Jian Hou
    Jianjun Liu
    Yumei Chen
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 50 : 2683 - 2691
  • [8] ASANGUINEOUS TOTAL-BODY PERFUSION
    NEELY, WA
    TURNER, MD
    HAINING, JL
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1963, 184 (09): : 718 - &
  • [9] A TOTAL-BODY VASCULAR PERFUSION TECHNIQUE
    GIFFIN, BF
    LEE, JC
    BAJPAI, PK
    CLINICAL RESEARCH, 1980, 28 (05): : A836 - A836
  • [10] Fully automated radiosynthesis of [11C]butanol
    Rodnick, Melissa
    Tluczek, Louis
    Scott, Peter
    Shao, Xia
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2017, 60 : S295 - S295