Three-dimensional electrical structure model of the Yangbajain geothermal field in Tibet: Evidence obtained from magnetotelluric data

被引:0
|
作者
Xue, Guoqiang [1 ,2 ]
Chen, Weiying [1 ,2 ]
Zhao, Ping [3 ]
Ren, Wangqi [4 ]
He, Yiming [1 ,2 ]
Lv, Pengfei [1 ,2 ]
Lei, Kangxin [1 ,2 ]
Zhao, Yang [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Geol & Geophys, Key Lab Mineral Resources, Beijing 100029, Peoples R China
[2] Univ Chinese Acad Sci, Coll Earth Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Inst Tibetan Plateau Res, State Key Lab Tibetan Plateau Earth Syst Resources, Beijing 100101, Peoples R China
[4] Cent South Univ, Sch Geosci & Info Phys, Changsha 410083, Peoples R China
基金
中国国家自然科学基金;
关键词
Geothermal field; Magnetotelluric; Partial melt body; 3D electrical structure; Thermal reservoir geological model; INVERSION; SYSTEM;
D O I
10.1007/s11430-022-1099-4
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The Yangbajain Geothermal Field in Tibet is located in the fault subsidence basin of the central Yadong-Gulu Rift Valley. The spatial distribution of the field is controlled by mountain-front fault zones on the northwestern and southeastern sides of the basin. Geothermal power has been generated in Yangbajain for more than 40 years. However, owing to the lack of three-dimensional (3D) geophysical exploration data, key geological issues related to the partial melt body of the Yangbajain Geothermal Field, such as its location, burial depth, and geometric form, as well as the ascending channel of the geothermal fluid, have for a long time been controversial. In this study, 3D inversion was performed using measured geo-electromagnetic total impedance tensor data from 47 survey points. The extracted horizontal sections at different depths and profiles, and at different lines, reflect the 3D electrical structure model of the geothermal field in the study area. Subsequently, three findings were obtained. First, the partial melt body, located below the China-Nepal Highway extending along the northeast direction, is the heat source of the Yangbajain Geothermal Field. The burial depth range of the molten body was determined to range between approximately 6.2 and 14 km. Moreover, the geothermal fluid ascended a horn-shaped circulation channel with an up-facing opening, located in the northern section of the sulfur ditch area. The study results revealed that deep rock fissures (>2 km) were not well developed and had poor permeability. In addition, no layered heat reservoirs with high water richness were observed in the northern part of the study area. However, the application of enhanced geothermal system (EGS) technology in the northern region would be essential to improving the power generation capacity of the Yangbajain Geothermal Field. In addition, the study found no deep high-temperature heat storage areas in the southern region of the study area.
引用
收藏
页码:1839 / 1852
页数:14
相关论文
共 50 条
  • [41] Geothermal potential of the eastern end of the Gediz basin, western Anatolia, Turkey revealed by three-dimensional inversion of magnetotelluric data
    Hacioglu, Ozlem
    Basokur, Ahmet Tugrul
    Diner, Cagri
    GEOTHERMICS, 2021, 91 (91)
  • [42] Electrical structure of a Qinghai-Tibet Plateau thunderstorm based on three-dimensional lightning mapping
    Li, Yajun
    Zhang, Guangshu
    Wen, Jun
    Wang, Daohong
    Wang, Yanhui
    Zhang, Tong
    Fan, Xiangpeng
    Wu, Bin
    ATMOSPHERIC RESEARCH, 2013, 134 : 137 - 149
  • [43] Three-Dimensional Electrical Resistivity Image of the Volcanic Arc in Northern Chile-An Appraisal of Early Magnetotelluric Data
    Kuehn, Christine
    Brasse, Heinrich
    Schwarz, Gerhard
    PURE AND APPLIED GEOPHYSICS, 2018, 175 (06) : 2153 - 2165
  • [44] A Three-Dimensional Model of the Affect Structure Based on the Russian Data
    Lyusin, D.
    PSYCHOLOGY-JOURNAL OF THE HIGHER SCHOOL OF ECONOMICS, 2019, 16 (02): : 341 - 356
  • [45] Electrical resistivity structure in the Tocomar geothermal system obtained from 3-D inversion of audio-magnetotelluric data (Central Puna, NW Argentina)
    Ahumada, M. F.
    Guevara, L.
    Favetto, A.
    Filipovich, R.
    Chiodi, A.
    Viramonte, J. G.
    Giordano, G.
    GEOTHERMICS, 2022, 104
  • [46] Three-dimensional magnetotelluric inversion in practice-the electrical conductivity structure of the San Andreas Fault in Central California
    Tietze, Kristina
    Ritter, Oliver
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2013, 195 (01) : 130 - 147
  • [47] Three-dimensional geothermal reservoir model using the magnetotelluric method in medium and deep strata of Yishu fault zone, Rizhao Section
    Du, Wenlong
    Zhou, Xingyu
    Sun, Yuanbin
    Wang, Shidang
    Zhang, Dabin
    Wang, Chen
    Zhang, Jinwei
    Ding, Renwei
    APPLIED GEOPHYSICS, 2024,
  • [48] A Mantle Plume Beneath South China Revealed by Electrical Conductivity Obtained from Three-Dimensional Inversion of Geomagnetic Data
    Li, Shiwen
    Liu, Yunhe
    Li, Jianping
    SENSORS, 2023, 23 (03)
  • [49] Three-dimensional electrical resistivity tomography and its application to Larderello Valle Secolo geothermal field in Tuscany, Italy
    Shi, WQ
    Rodi, W
    Toksoz, MN
    Morgan, FD
    Fiordelisi, A
    Cameli, GM
    SYMPOSIUM ON THE APPLICATION OF GEOPHYSICS TO ENGINEERING AND ENVIRONMENTAL PROBLEMS, VOLS 1 & 2, 1997, : 889 - 899
  • [50] Three-dimensional crustal structure of the capital area obtained by a joint inversion of DSS data from multiple profiles
    Li, SL
    Zhang, XK
    Song, ZL
    Shi, JH
    Deng, HZ
    Yang, J
    Zhang, CK
    Ren, QF
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2001, 44 (03): : 360 - +