A salivary glucose biosensor based on immobilization of glucose oxidase in Nafion-carbon nanotubes nanocomposites modified on screen printed electrode

被引:15
|
作者
Liu, Chung-Tzu [1 ]
Liu, Ching-Hao [1 ]
Lai, Yi-Ting [2 ,3 ,4 ]
Lee, Chi-Young [1 ]
Gupta, Shivam [1 ]
Tai, Nyan-Hwa [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Mat Sci & Engn, 101,Sec 2,Kuang Fu Rd, Hsinchu 300, Taiwan
[2] Ming Chi Univ Technol, Dept Mat Engn, New Taipei 24301, Taiwan
[3] Ming Chi Univ Technol, Ctr Plasma & Thin Film Technol, New Taipei 24301, Taiwan
[4] Ming Chi Univ Technol, Biochem Technol R&D Ctr, New Taipei 24301, Taiwan
关键词
Diabetes; Non-invasive; Enzyme; Plasma; CNTs; SENSORS; NANOPARTICLES; PERFORMANCE;
D O I
10.1016/j.microc.2023.108872
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Due to unhealthy lifestyles, the population of diabetics is rapidly increasing, therefore, the demand of glucose meter is also increasing. However, not all the people could overcome the fear of jabbing a needle during blood glucose tests. In this regard, we report a non-invasive glucose sensing electrode composed of conductive and biocompatible Nafion-carbon nanotubes (Nf-CNT) nanocomposite and glucose oxidase (GOx), which are sequentially coated on screen-printed electrode (SPE). The Nf-CNT nanocomposite is prepared through ultrasonication followed by drop casting it onto the SPE. Subsequently, Nf-CNT/SPEs are subjected to plasma treatment followed by drop-casting of GOx to fabricate GOx/Nf-CNT/SPE electrodes. The plasma treatment alters the hydrophobic nature of Nf-CNT/SPE, which not only exposes the surface of Nf-CNT layer, but also enables it for uniform coating of GOx. The results confirm that the mixing ratio of Nafion and CNT as well as plasma treatment time significantly affects sensing performance. The GOx/Nf-CNT/SPE subjected to 1 min of plasma treatment prior to the coating of GOx shows the best performance with a sensitivity of 99.13 mu A/mMcm2 and a linear range of 20-700 mu M. Moreover, the GOx/Nf-CNT/SPE electrodes are also tested under artificial saliva, which shows their high potential in the diagnosis of diabetes.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Glucose biosensor based on screen-printed electrode modified with silicone sol-gel conducting matrix containing carbon nanotubes
    Kamanina, O. A.
    Kamanin, S. S.
    Kharkova, A. S.
    Arlyapov, V. A.
    3 BIOTECH, 2019, 9 (07)
  • [22] A Glucose Biosensor Based on Glucose Oxidase enzyme and ZnO Nanoparticles Modified Carbon Paste Electrode
    Shamsazar, Ali
    Shamsazar, Fatemeh
    Asadi, Asadollah
    Rezaei-Zarchi, Saeed
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (12): : 9891 - 9901
  • [23] Composite glucose biosensor based on screen-printed electrodes bulk modified with Prussian blue and glucose oxidase
    Pravda, M
    O'Halloran, MP
    Kreuzer, MP
    Guilbault, GG
    ANALYTICAL LETTERS, 2002, 35 (06) : 959 - 970
  • [24] Amperometric Determination of Glucose with FeO and Glucose Oxidase Bulk-Modified Screen-Printed Carbon Ink Biosensor
    Turkusic, E.
    Begic, S.
    Kahrovic, E.
    Kalcher, K.
    HEALTHMED, 2011, 5 (05): : 1117 - 1122
  • [25] Evaluating bioreceptor immobilization on Gold Nanospike (AuNS)-modified Screen-Printed Carbon Electrode (SPCE) as enzymatic glucose biosensor
    Majidah, Salma
    Rizalputri, Lavita Nuraviana
    Ariasena, Eduardus
    Raditya, Aldyla Nisa
    Ropii, Bejo
    Salsabila, Nadia
    Handayani, Murni
    Hartati, Yeni Wahyuni
    Anshori, Isa
    NANOCOMPOSITES, 2024, 10 (01) : 139 - 151
  • [26] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the platinum electrode modified with NiO doped ZnO nanorods
    Chu, Xiangfeng
    Zhu, Xiaohua
    Dong, Yongping
    Chen, Tongyun
    Ye, Mingfu
    Sun, Wenqi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 676 : 20 - 26
  • [27] Glucose biosensor based on multi-wall carbon nanotubes and screen printed carbon electrodes
    Guan, WJ
    Li, Y
    Chen, YQ
    Zhang, XB
    Hu, GQ
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (03): : 508 - 512
  • [28] A high-performance glucose ECL biosensor based on immobilization of glucose oxidase on polyelectrolyte-chitosan-modified glassy carbon electrode
    Dai, H.
    Wang, Y.
    Wu, X.
    Chen, G.
    Chen, H.
    LUMINESCENCE, 2008, 23 (02) : 65 - 65
  • [29] Amperometric glucose biosensor. Electrode modified with carbon nanotubes
    Gutierrez, Alejandro
    Rodriguez, Marcela C.
    Galicia, Laura
    Rivas, Gustavo A.
    MES 26: ELECTROCHEMISTRY AS A TOOL FOR SUSTAINABLE DEVELOPMENT, 2011, 36 (01): : 393 - 400
  • [30] A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode
    Lim, SH
    Wei, J
    Lin, JY
    Li, QT
    KuaYou, J
    BIOSENSORS & BIOELECTRONICS, 2005, 20 (11): : 2341 - 2346