Highly specific detection of Neisseria gonorrhoeae based on recombinase polymerase amplification-initiated strand displacement amplification

被引:7
|
作者
Fan, Mengnan [1 ,2 ]
Yang, Jianru [1 ,2 ]
Wang, Xiaosu [1 ,2 ]
Xu, Yongjie [3 ]
Li, Bing [1 ,2 ]
Yang, Hui [1 ,2 ]
Lu, Qin [1 ,2 ]
Min, Xun [1 ,2 ]
Huang, Meirong [4 ]
Huang, Jian [1 ,2 ]
机构
[1] Zunyi Med Univ, Dept Lab Med, Affiliated Hosp, Zunyi 563000, Peoples R China
[2] Zunyi Med Univ, Sch Lab Med, Zunyi 563000, Peoples R China
[3] Guizhou Prov Peoples Hosp, Dept Lab Med, Guiyang 550002, Peoples R China
[4] Zunyi Med Univ, Dept Blood Transfus, Affiliated Hosp, Zunyi 563000, Peoples R China
基金
中国国家自然科学基金;
关键词
Neisseria gonorrhoeae; Recombinase polymerase amplification; Strand displacement amplification; Molecular beacon; CLINICAL UTILITY; MICROSCOPY; WOMEN;
D O I
10.1016/j.aca.2023.341956
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Neisseria gonorrhoeae is the only pathogen that causes gonorrhea, and can have serious consequences if left untreated. A simple and accurate detection method for N. gonorrhoeae is essential for the diagnosis of gonorrhea and the appropriate prescription of antibiotics. The application of isothermal recombinase polymerase amplifi-cation (RPA) to detect this pathogen is advantageous because of its rapid performance, high sensitivity, and minimal dependency on equipment. However, this simplicity is offset by the risk of false-positive signals from primer-dimers and primer-probe dimers. In this study, RPA-initiated strand displacement amplification (SDA) was established for the detection of N. gonorrhoeae, and eliminated false-positive signals from primer-dimers and primer-probe dimers. The developed biosensor allows for the reduced generation of nonspecific RPA amplifi-cation through the design of enzyme cleavage sites on primers, introduction of SDA, and detection of the final product using a molecular beacon (MB). Using this system, the DNA double strand is transformed into single -stranded DNA following SDA, thereby providing a more suitable binding substrate and improving the effi-ciency of MB detection. Amplification can be conducted below 37 degrees C, and the process can be completed within 90 min. The limit of detection was determined to be 0.81 copies/mu L. This system is highly specific for N. gonorrhoeae and exhibits no cross-reactivity with other common urogenital pathogens. The results of this study are consistent with those of real-time PCR performed on clinical specimens of urogenital secretions. In summary, the biosensor is a simple and specific detection method for N. gonorrhoeae.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A dual amplification fluorescent strategy for sensitive detection of DNA methyltransferase activity based on strand displacement amplification and DNAzyme amplification
    Cui, Wanling
    Wang, Lei
    Jiang, Wei
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 650 - 655
  • [32] A recombinase polymerase amplification-based assay for rapid detection of Chlamydia psittaci
    Pang, Yanling
    Cong, Feng
    Zhang, Xinheng
    Li, Hongxin
    Chang, Yung-Fu
    Xie, Qingmei
    Lin, Wencheng
    POULTRY SCIENCE, 2021, 100 (02) : 585 - 591
  • [33] A Sensitive and Rapid Assay for Mycoplasma hominis Detection Based on Recombinase Polymerase Amplification
    Chen, Xiaoying
    Wang, Yichao
    Zhu, Jie
    Zhu, Tao
    Yang, Hehui
    Miao, Leilei
    Xu, Jiajia
    Xi, Fengxiang
    Wang, Pan
    Jia, Tianjun
    Li, Zhaoyun
    CLINICAL LABORATORY, 2021, 67 (04) : 1042 - 1051
  • [34] RAPID DETECTION OF <it>MYCOBACTERIUM ULCERANS</it> INFECTION BY RECOMBINASE POLYMERASE AMPLIFICATION
    Frimpong, Michael
    Ahor, Hubert
    Naana-Sarpong, Francisca
    Wansbrough-Jones, Mark
    Phillips, Richard
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2018, 99 (04): : 155 - 156
  • [35] Simultaneously sensitive detection of multiple miRNAs based on a strand displacement amplification
    Tian, Tian
    Xiao, Heng
    Zhang, Xiaolian
    Peng, Shuang
    Zhang, Xiaoe
    Guo, Shan
    Wang, Shaoru
    Liu, Songmei
    Zhou, Xin
    Meyers, Craig
    Zhou, Xiang
    CHEMICAL COMMUNICATIONS, 2013, 49 (01) : 75 - 77
  • [36] The establishment of a recombinase polymerase amplification technique for the detection of mouse poxvirus
    Yuexiao Lian
    Mengdi Zhang
    Yujun Zhu
    Miaoli Wu
    Bihong Huang
    Li Xiao
    Kehang Shi
    Peide Li
    Feng Cong
    Huanan Wang
    BMC Veterinary Research, 19
  • [37] The establishment of a recombinase polymerase amplification technique for the detection of mouse poxvirus
    Lian, Yuexiao
    Zhang, Mengdi
    Zhu, Yujun
    Wu, Miaoli
    Huang, Bihong
    Xiao, Li
    Shi, Kehang
    Li, Peide
    Cong, Feng
    Wang, Huanan
    BMC VETERINARY RESEARCH, 2023, 19 (01)
  • [38] Recombinase Polymerase Amplification Assay for Rapid Detection of Francisella tularensis
    Euler, Milena
    Wang, Yongjie
    Otto, Peter
    Tomaso, Herbert
    Escudero, Raquel
    Anda, Pedro
    Hufert, Frank T.
    Weidmann, Manfred
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (07) : 2234 - 2238
  • [39] A recombinase polymerase amplification assay for rapid detection of rabies virus
    Faye, Martin
    Abd El Wahed, Ahmed
    Faye, Oumar
    Kissenkoetter, Jonas
    Hoffmann, Bernd
    Sall, Amadou Alpha
    Faye, Ousmane
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [40] Development and Application of a Recombinase Polymerase Amplification Assay for Detection of Salmonella
    Liu, Libing
    Geng, Yunyun
    Jiang, Yanfen
    Liu, Siying
    Sun, Xiaoxia
    Nan, Huizhu
    Wang, Jianchang
    Shipin Kexue/Food Science, 2019, 40 (02): : 298 - 303