Quantifying maxillary anterior tooth movement in digital orthodontics: Does the choice of the superimposition software matter?

被引:5
|
作者
Adel, Samar M. [1 ,6 ]
Vaid, Nikhilesh R. [2 ,3 ]
El-Harouni, Nadia [1 ]
Kassem, Hassan [1 ]
Park, Jae Hyun [4 ,5 ]
Zaher, Abbas R. [1 ]
机构
[1] Alexandria Univ, Fac Dent, Dept Orthodont, Alexandria, Egypt
[2] Saveetha Inst Med & Tech Sci, Saveetha Dent Coll, Dept Orthodont, Chennai, India
[3] Only Orthodont, Mumbai, India
[4] AT Still Univ, Arizona Sch Dent & Oral Hlth, Postgrad Orthodont Program, Mesa, AZ USA
[5] Kyung Hee Univ, Grad Sch Dent, Seoul, South Korea
[6] Alexandria Univ, Fac Dent, Dept Orthodont, Champol St, El Azarita, Alexandria, Egypt
关键词
3D Digital models; Artificial intelligence; Clear aligner therapy; Digital setup; Maxillary anterior 3D tooth movement; Registration; BEAM COMPUTED-TOMOGRAPHY; PALATAL SUPERIMPOSITION; MOLAR MOVEMENT; RELIABILITY; ACCURACY; VALIDITY; MODELS;
D O I
10.1016/j.ejwf.2023.07.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: To compare the agreement between predetermined angular and linear tooth movement measurements processed with three digital model registration software packages.Methods: Twenty maxillary intraoral pretreatment scans of patients undergoing clear aligner therapy were randomly selected. Digital setups were generated using OrthoAnalyzer Clear Aligner Studio software to serve as the reference standard. Both pretreatment scans and setups were converted to STL files and exported to Geomagic, OrthoAnalyzer-Model Set Compare, and Compare model registration software packages. The amount of tooth movement of the maxillary incisors and canines was calculated in six degrees of freedom.Results: Statistical significance of the obtained results was expressed at P < 0.01 to account for multiple comparisons. The maxillary central incisors showed the highest agreement for torque and rotation as measured by all software programs. Lateral incisors showed the least agreement in linear movements as measured by Geomagic and Compare, and for tip as measured by Geomagic and OrthoAnalyzer. Maxillary canines had the highest agreement for all linear movements as measured by Geomagic and Compare, and tip as measured by Geomagic and OrthoAnalyzer. Geomagic showed excellent agreement for all measurements except for torque, whereas Compare showed excellent agreement only for rotation and linear measurements. OrthoAnalyzer showed moderate agreement for all measurements except for rotation, which showed good agreement. Conclusions: Maxillary central incisor measurements showed higher agreement compared with measurements of the maxillary lateral incisors and canines. Although none of the software showed poor agreement, Geomagic seemed to have the highest accuracy. (c) 2023 World Federation of Orthodontists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:187 / 196
页数:10
相关论文
共 28 条
  • [21] Precise extraction of impacted supernumerary tooth in the maxillary anterior region with a digital guide plate A case report
    Zhu, Fangyong
    Hou, Deqiang
    Zhou, Chen
    Chen, Zhifei
    Cao, Yannan
    Ji, Lian
    Zou, Jianming
    Xu, Yanhua
    MEDICINE, 2022, 101 (20)
  • [22] integrated three-dimensional digital assessment of accuracy of anterior tooth movement using clear aligners
    Zhang, Xiao-Juan
    He, Li
    Guo, Hong-Ming
    Tian, Jie
    Bai, Yu-Xing
    Li, Song
    KOREAN JOURNAL OF ORTHODONTICS, 2015, 45 (06) : 275 - 281
  • [23] Assessment of simulated vs actual orthodontic tooth movement with a customized fixed lingual appliance using untreated posterior teeth for registration and digital superimposition: A retrospective study
    Sharp, Irina G.
    Minick, Gerald
    Carey, Clifton
    Shellhart, Craig W.
    Tilliss, Terri
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 161 (02) : 272 - 280
  • [24] Effect of power arm on anterior tooth movement in sliding mechanics analyzed using a three-dimensional digital model
    Rokutanda, Hiromi
    Koga, Yoshiyuki
    Yanagida, Hiroko
    Tominaga, Jun-ya
    Fujimura, Yuji
    Yoshida, Noriaki
    ORTHODONTIC WAVES, 2015, 74 (04) : 93 - 98
  • [25] Type of tooth movement during en masse retraction of the maxillary anterior teeth using labial versus lingual biocreative therapy in adults: A randomized clinical trial
    Sadek, Mais M.
    Sabet, Noha E.
    Hassan, Islam T.
    KOREAN JOURNAL OF ORTHODONTICS, 2019, 49 (06) : 381 - 392
  • [26] Anterior uveitis in patients with spondyloarthritis treated with secukinumab or tumour necrosis factor inhibitors in routine care: does the choice of biological therapy matter?
    Lindstrom, Ulf
    Bengtsson, Karin
    Olofsson, Tor
    Di Giuseppe, Daniela
    Glintborg, Bente
    Forsblad-d'Elia, Helena
    Jacobsson, Lennart T. H.
    Askling, Johan
    ANNALS OF THE RHEUMATIC DISEASES, 2021, 80 (11) : 1445 - 1452
  • [27] Anterior cruciate ligament reconstruction autograft choice: Bone-tendon-bone versus hamstring - Does it really matter? A systematic review
    Spindler, KR
    Kuhn, JE
    Freedman, KB
    Matthews, CE
    Dittus, RS
    Harrell, FE
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (08): : 1986 - 1995
  • [28] Arterial input choice in CTP map construction with acute MCA thrombus: Does side matter? Not if delay correction software is used proximal to the occlusion.
    Ferreira, Rafael M.
    Goldmakher, Gregory
    Kamalian, Shahmir
    Schaefer, Pamela W.
    Gonzalez, R. Gilberto
    Lev, Michael H.
    STROKE, 2008, 39 (02) : 585 - 585