Detection of Signal of Fire Source for Coal Spontaneous Combustion Applied with Acoustic Wave

被引:6
|
作者
Ren, Shuaijing [1 ,2 ]
Zhang, Yanni [1 ,3 ]
Xiao, Yang [1 ,3 ]
Deng, Jun [1 ,3 ]
Ma, Teng [1 ,2 ]
Zhang, Yutao [1 ,3 ]
机构
[1] Xian Univ Sci & Technol, Sch Safety Sci & Engn, 58 Yanta Mid Rd, Xian 710054, Shaanxi, Peoples R China
[2] Xian Univ Sci & Technol, Sch Energy Engn, 58 Yanta Mid Rd, Xian 710054, Shaanxi, Peoples R China
[3] Xian Univ Sci & Technol, Shaanxi Key Lab Prevent & Control Coal Fire, 58 Yanta Mid Rd, Xian 710054, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Coal spontaneous combustion; Fire source detection; Acoustic wave; Sound source signal; Cross-correlation; TEMPERATURE DISTRIBUTION; GASES; FLOW; RECONSTRUCTION; MINE;
D O I
10.1007/s11053-023-10225-0
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Coal spontaneous combustion can cause a series of problems in terms of wasted resources, casualties, and environmental pollution. Accurate detection of the fire source in loose coal is the key to preventing coal spontaneous combustion. Acoustic temperature measurement has significant advantages of strong stability, high accuracy, and wide measurement range, which can make up for the shortcomings of traditional fire source detection methods. Detecting the optimum source signal for loose coal temperature measurement is the basis and prerequisite for the realization of acoustic temperature measurement. Therefore, the anti-interference characteristics of three typical sound source signals were tested and analyzed through a self-designed sound wave propagation characteristic test system. The cross-correlations among maximum length sequence signal, pulse signal, and linear sweep signal were compared and analyzed. Compared to the other two signals, the main peak of the cross-correlation coefficient of the linear sweep signal was more prominent and its pseudo-peaks interfered less with its main peak. This signal had strong anti-interference ability, and it can be used as a basic acoustic source signal for temperature measurement of loose coal. To further screen out the optimal frequency band and length of the linear sweep signal, four bituminous coals were selected as the propagation medium. The main peak value and the difference between the main peak and the maximum pseudo-peak of the cross-correlation coefficient were proposed as the evaluation indicators. The optimum signal frequency bands of long-flame coal, non-caking coal, coking coal, and lean coal were 400-900, 400-900, 500-1200, and 400-900 Hz, and the optimum signal length of four coals was 0.1 s. The study results can provide theoretical support for the selection of acoustic temperature measurement signals for loose coal.
引用
收藏
页码:2243 / 2256
页数:14
相关论文
共 50 条
  • [1] Detection of Signal of Fire Source for Coal Spontaneous Combustion Applied with Acoustic Wave
    Shuaijing Ren
    Yanni Zhang
    Yang Xiao
    Jun Deng
    Teng Ma
    Yutao Zhang
    Natural Resources Research, 2023, 32 : 2243 - 2256
  • [2] Initial exploration on potential fire hazards detection from coal spontaneous combustion applied by acoustic wave
    Ren, Shuai-Jing
    Zhang, Yan-Ni
    Song, Ze-Yang
    Xiao, Yang
    Deng, Jun
    Shu, Chi-Min
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 897
  • [3] Early Detection of Coal Spontaneous Combustion by Complex Acoustic Waves in a Concealed Fire Source
    Guo, Jun
    Shang, Haoyu
    Cai, Guobin
    Jin, Yongfei
    Wang, Kaixuan
    Li, Shuai
    ACS OMEGA, 2023, 8 (19): : 16519 - 16531
  • [4] Investigation on high temperature point detection of spontaneous combustion of loose coal based on optimal acoustic signal
    Deng, Jun
    Qu, Gaoyan
    Ren, Shuaijing
    Wang, Caiping
    Xiao, Yang
    Wang, Jinrui
    Sa, Bo
    Duan, Xiadan
    Yang, Nannan
    Zhao, Xiaqi
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2024, 185 : 423 - 434
  • [5] RADON MEASURING TO DETECT COAL SPONTANEOUS COMBUSTION FIRE SOURCE AT BULIANTA MINE, SHENDONG
    Wu, Jianming
    Wu, Yuguo
    Wang, Junfeng
    Zhou, Chunshan
    PROCEEDINGS OF THE 2012 COAL OPERATORS' CONFERENCE, 2012, : 301 - 305
  • [6] Research on positioning system of WSN-based fire source of coal spontaneous combustion
    Deng Ming
    Zhang Guoshu
    Chen Yun
    Qin Ruxiang
    3RD INTERNATIONAL SYMPOSIUM ON MODERN MINING & SAFETY TECHNOLOGY PROCEEDINGS, 2008, : 531 - 535
  • [7] Exploration and Frontier of Coal Spontaneous Combustion Fire Prevention Materials
    Han, Dandan
    Niu, Guchen
    Zhu, Hongqing
    Chang, Tianyao
    Liu, Bing
    Ren, Yongbo
    Wang, Yu
    Song, Baolin
    PROCESSES, 2024, 12 (06)
  • [8] Study on prediction of spontaneous combustion fire in goaf of coal mine
    Wang, Ruiqi
    Liu, Zihao
    Sun, Zichao
    Wang, Jialu
    Wang, Weiqun
    Wang, Xingyu
    Liu, Jifan
    INTERNATIONAL CONFERENCE ON INTELLIGENT EQUIPMENT AND SPECIAL ROBOTS (ICIESR 2021), 2021, 12127
  • [9] Application of Composite Fly Ash Gel to Extinguish Fire in Coal Spontaneous Combustion Fire
    Qi, Yan
    2011 INTERNATIONAL CONFERENCE ON APPLIED SOCIAL SCIENCE (ICASS 2011), VOL III, 2011, : 436 - 440
  • [10] Locating method of fire source for spontaneous combustion of sulfide ores
    刘辉
    吴超
    石英
    Journal of Central South University of Technology, 2011, 18 (04) : 1034 - 1040