Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis

被引:16
|
作者
Diaconu, Alexandru [1 ]
Holte, Michael Boelstoft [1 ,2 ]
Berg-Beckhoff, Gabriele [3 ]
Pinholt, Else Marie [1 ,2 ]
机构
[1] Univ Hosp Southern Denmark, Dept Oral & Maxillofacial Surg, 3D Lab Denmark, Finsensgade 35, DK-6700 Esbjerg, Denmark
[2] Univ Southern Denmark, Fac Hlth Sci, Dept Reg Hlth Res, Finsensgade 35, DK-6700 Esbjerg, Denmark
[3] Univ Southern Denmark, Fac Hlth Sci, Dept Publ Hlth, Degnevej 14, DK-6705 Esbjerg, Denmark
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 01期
关键词
patient-specific implants; orthognathic surgery; accuracy; stability; three-dimensional; systematic review; meta-analysis; CUSTOMIZED SURGICAL GUIDES; PATIENT-SPECIFIC IMPLANTS; TITANIUM PLATES; CUTTING GUIDES; SUPERIMPOSITION; OSTEOSYNTHESIS; FIXATION; REGISTRATION; VALIDATION; PROTOCOL;
D O I
10.3390/jpm13010125
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
This systematic review aimed to determine the accuracy/stability of patient-specific osteosynthesis (PSI) in orthognathic surgery according to three-dimensional (3D) outcome analysis and in comparison to conventional osteosynthesis and computer-aided designed and manufactured (CAD/CAM) splints or wafers. The PRISMA guidelines were followed and six academic databases and Google Scholar were searched. Records reporting 3D accuracy/stability measurements of bony segments fixated with PSI were included. Of 485 initial records, 21 met the eligibility (566 subjects), nine of which also qualified for a meta-analysis (164 subjects). Six studies had a high risk of bias (29%), and the rest were of low or moderate risk. Procedures comprised either single-piece or segmental Le Fort I and/or mandibular osteotomy and/or genioplasty. A stratified meta-analysis including 115 subjects with single-piece Le Fort I PSI showed that the largest absolute mean deviations were 0.5 mm antero-posteriorly and 0.65 degrees in pitch. PSIs were up to 0.85 mm and 2.35 degrees more accurate than conventional osteosynthesis with CAD/CAM splint or wafer (p < 0.0001). However, the clinical relevance of the improved accuracy has not been shown. The literature on PSI for multi-piece Le Fort I, mandibular osteotomies and genioplasty procedure is characterized by high methodological heterogeneity and a lack of randomized controlled trials. The literature is lacking on the 3D stability of bony segments fixated with PSI.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Does Orthognathic Surgery Cause or Cure Temporomandibular Disorders? A Systematic Review and Meta-Analysis
    Al-Moraissi, Essam Ahmed
    Wolford, Larry M.
    Perez, Daniel
    Laskin, Daniel M.
    Ellis, Edward, III
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (09) : 1835 - 1847
  • [42] Upper airway dimensions in patients undergoing orthognathic surgery: a systematic review and meta-analysis
    Christovam, I. O.
    Lisboa, C. O.
    Ferreira, D. M. T. P.
    Cury-Saramago, A. A.
    Mattos, C. T.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (04) : 460 - 471
  • [43] Tranexamic acid reduces blood loss in orthognathic surgery - a systematic review and meta-analysis
    Mansour, Hamid Reza Khademi
    Khajuria, Ankur
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2024, 62 (10): : 968 - 968
  • [44] Assessment of masticatory performance in patients undergoing orthognathic surgery: A systematic review and meta-analysis
    Bunpu, Pokchat
    Changsiripun, Chidsanu
    JOURNAL OF ORAL REHABILITATION, 2023, 50 (07) : 596 - 616
  • [45] Three-dimensional versus two-dimensional laparoscopic right colectomy: a systematic review and meta-analysis
    Vettoretto, Nereo
    Reggiani, Luisa
    Cirocchi, Roberto
    Henry, Brandon Michael
    Covarelli, Piero
    D'Andrea, Vito
    Popivanov, Georgi
    Randolph, Justus
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2018, 33 (12) : 1799 - 1801
  • [46] Two-Dimensional Versus Three-Dimensional Laparoscopic Systems in Urology: A Systematic Review and Meta-Analysis
    Dirie, Najib Isse
    Wang, Qing
    Wang, Shaogang
    JOURNAL OF ENDOUROLOGY, 2018, 32 (09) : 781 - 790
  • [47] Two-dimensional versus three-dimensional laparoscopy in surgical efficacy: a systematic review and meta-analysis
    Cheng, Ji
    Gao, Jinbo
    Shuai, Xiaoming
    Wang, Guobin
    Tao, Kaixiong
    ONCOTARGET, 2016, 7 (43) : 70979 - 70990
  • [48] Three-dimensional versus two-dimensional laparoscopic right colectomy: a systematic review and meta-analysis
    Nereo Vettoretto
    Luisa Reggiani
    Roberto Cirocchi
    Brandon Michael Henry
    Piero Covarelli
    Vito D’Andrea
    Georgi Popivanov
    Justus Randolph
    International Journal of Colorectal Disease, 2018, 33 : 1799 - 1801
  • [49] Three-dimensional cone beam computed tomography analysis protocols for condylar remodelling following orthognathic surgery: a systematic review
    Verhelst, P. J.
    Verstraete, L.
    Shaheen, E.
    Shujaat, S.
    Darche, V
    Jacobs, R.
    Swennen, G.
    Politis, C.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (02) : 207 - 217
  • [50] Diagnostic accuracy of three-dimensional contrast-enhanced ultrasound for focal liver lesions A protocol for systematic review and meta-analysis
    Qu, Meijng
    Jia, Zhaohua
    Sun, Lipeng
    Wang, Hui
    MEDICINE, 2021, 100 (51)