Efficacy and Safety of Covered Stents Versus Bare-Metal Stents for Aortoiliac Occlusive Disease: A Systematic Review and Meta-Analysis

被引:1
|
作者
Hu, Chenming [1 ,2 ]
Chen, Lang [1 ]
Wu, Min [1 ]
Ye, Qianling [2 ]
Zou, Jun [2 ]
Zhao, Bin [2 ]
Li, Xiang [2 ]
Wu, Huaping [1 ,2 ,3 ]
机构
[1] North Sichuan Med Coll, Sch Clin Med, Nanchong, Peoples R China
[2] Dazhou Cent Hosp, Dept Vasc Surg, Dazhou, Peoples R China
[3] North Sichuan Med Coll, Sch Clin Med, 56 Nanyuemiao St, Dazhou, Sichuan, Peoples R China
关键词
aortoiliac occlusive disease; bare-metal stent; covered stent; endovascular therapy; meta-analysis; peripheral artery disease; stent; PERIPHERAL ARTERY-DISEASE; BALLOON-EXPANDABLE STENTS; ENDOVASCULAR TREATMENT; EDITORS CHOICE; RISK-FACTORS; OUTCOMES; MANAGEMENT; SOCIETY; TRIAL; ANGIOPLASTY;
D O I
10.1177/15266028241237387
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: This study aimed to assess the efficacy and safety outcome of covered stents (CSs), as compared with bare-metal stents (BMSs), for the treatment of patients with aortoiliac occlusive disease (AIOD). Materials and methods: A systematic literature search was conducted in PubMed, Embase, and Cochrane Library up to August 2023 to identify all studies comparing efficacy and safety outcomes of CSs versus BMSs for treating AIOD. Our outcome was primary patency, secondary patency, technical success, ankle-brachial index (ABI) variation, target lesion revascularization (TLR), limb salvage, complications, and long-term survival. Dichotomous outcomes were pooled as relative risks (RR) or hazard ratio with the 95% confidence interval (CI). Continuous outcomes were pooled as weighted mean differences and 95% CI. Model selection was based on the heterogeneity of the included studies. Results: There were 10 studies (2 randomized controlled trials, 8 retrospective cohort studies), comprising 1676 sample size. Compared with BMSs, CSs use was associated with better primary patency of patients with a Trans-Atlantic Inter-Society Consensus II (TASC) D lesion (RR, 1.15, 95% CI, 1.04 to 1.27, p=0.007), TLR (RR, 0.39, 95% CI, 0.27 to 0.56, p<0.001), technical success (RR, 1.01, 95% CI, 1.00 to 1.02, p=0.010), and long-term survival (RR, 1.06, 95% CI, 1.01 to 1.11, p=0.020). There is no difference between CSs and BMSs regarding primary patency of all patients, secondary patency, variation in ABI, limb salvage, and complications. Conclusions: Compared with BMSs, CSs used in AIOD was associated with more favorable primary patency in patients with TASC D lesions, TLR, technical success rates, and patient long-term survival. These results provide evidence of the advantages of using CSs for AIOD treatment. Future studies focusing on long-term variations in ABI, primary patency of different degrees of calcification, vascular segments, and TASC classification are warranted. Clinical Impact Although several studies evaluated the clinical efficacy of CS in the context of AIOD treatment, the significance and consistency of these findings were not determined to date. We found that CS was used in AIOD associated with better technical success rate, long-term patient survival, lower target lesion revascularization, and higher primary patency of patients with a Trans-Atlantic Inter-Society Consensus II D lesion when compared with BMSs. Our study provides evidence supporting the superiority of CSs over BMSs in the treatment of AIOD, and furnishing clinicians with guidance for treatment decisions.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Outcomes of covered versus bare-metal balloon-expandable stents for aortoiliac occlusive disease
    Humphries, Misty D.
    Armstrong, Ehrin
    Laird, John
    Paz, Jessica
    Pevec, William
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 60 (02) : 337 - 343
  • [2] Covered Stents vs Bare Metal Stents for Aortoiliac Arterial Diseases: A Systematic Review and Meta-Analysis
    Zeng, Chenlin
    Wu, Zhaoyu
    Lei, Jiahao
    Pu, Hongji
    Qiu, Peng
    Peng, Zhaoxi
    Liu, Yijun
    Ye, Kaichuang
    Lu, Xinwu
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2023,
  • [3] Outcomes of covered stents versus bare-metal stents for subclavian artery occlusive disease
    Wei, Libing
    Gao, Xixiang
    Tong, Zhu
    Cui, Shijun
    Guo, Lianrui
    Gu, Yongquan
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [5] Regarding "Outcomes of covered versus bare-metal balloon-expandable stents for aortoiliac occlusive disease"
    Grimme, Frederike A. B.
    Reijnen, Michel M. J. P.
    Zeebregts, Clark J.
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 60 (04) : 1120 - 1120
  • [6] Covered Stents for Endovascular Treatment of Aortoiliac Occlusive Disease: A Systematic Review and Meta-Analysis
    Mallory, Austin
    Giannopoulos, Stefanos
    Lee, Paul
    Kokkinidis, Damianos G.
    Armstrong, Ehrin J.
    [J]. VASCULAR AND ENDOVASCULAR SURGERY, 2021, 55 (06) : 560 - 570
  • [7] Midterm Outcomes of Covered Versus Bare-Metal Balloon-Expandable Stents for Aortoiliac Occlusive Disease
    Humphries, Misty
    Armstrong, Ehrin
    Laird, John
    Paz, Jessica
    Pevec, William
    [J]. JOURNAL OF VASCULAR SURGERY, 2013, 58 (02) : 564 - 565
  • [8] Comparative Efficacy and Safety of Bare-Metal versus DrugEluting Stents in Managing Saphenous Venous Graft Disease: A Meta-Analysis and Systematic Review
    Rahman, Mansoor
    Hanif, Muhammad
    Mumtaz, Mahrukh
    Nair, Abhinav
    Ali, Junaid
    Khan, Babar
    Ullah, Waqas
    Savage, Michael P.
    [J]. CIRCULATION, 2023, 148
  • [9] Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis
    Qiao, Yanxiang
    Bian, Yuan
    Yan, Xianliang
    Liu, Zhenfang
    Chen, Yuguo
    [J]. CARDIOVASCULAR JOURNAL OF AFRICA, 2013, 24 (07) : 274 - 279
  • [10] Drug-eluting stents versus bare-metal stents in acute myocardial infarction: A systematic review and meta-analysis
    Suh, Hae Sun
    Song, Hyun Jin
    Choi, Ji Eun
    Jang, Eun Jin
    Son, Hee Jeong
    Lee, Sang Moo
    Kim, Jung-Sun
    Choi, Donghoon
    [J]. INTERNATIONAL JOURNAL OF TECHNOLOGY ASSESSMENT IN HEALTH CARE, 2011, 27 (01) : 11 - 22