Enhancing the performance of a greenhouse dryer with natural dolomite powder-embedded latent heat thermal energy storage unit and air-to-air heat recovery system

被引:15
|
作者
Selimefendigil, Fatih [1 ,2 ]
Sirin, Ceylin [3 ,4 ,5 ]
机构
[1] King Faisal Univ, Coll Engn, Mech Engn Dept, Al Hufuf 31982, Saudi Arabia
[2] Manisa Celal Bayar Univ, Dept Mech Engn, Manisa, Turkiye
[3] Univ Galway, Sch Engn, Coll Sci & Engn, Galway, Ireland
[4] Natl Univ Ireland, Ryan Inst, MaREI Ctr, Galway H91 TK33, Ireland
[5] Univ Galway, Coll Sci & Engn, Sch Engn, Galway, Ireland
关键词
Greenhouse dryer; Latent heat storage; Natural dolomite powder; Air-to-air; Heat recovery system; INDIRECT SOLAR DRYER; PHASE-CHANGE MATERIAL; FORCED-CONVECTION; DRYING SYSTEM; PUMP; EXERGY; IMPROVEMENT; COLLECTOR; KINETICS; DRIER;
D O I
10.1016/j.solener.2023.111881
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Greenhouse drying systems (GDSs) are grouped in direct-type solar dryers and are widely utilised because of their easy applicability, high product drying capacity and cost-effectiveness. In the present work, it is aimed to improve the drying performance of a GDS by using natural dolomite powder-embedded latent heat thermal energy storage unit (LHTESU) and air-to-air heat recovery system (HRS). In this context, three different types of GDSs have been designed and manufactured including a GDS with paraffin-based LHTESU, a GDS with natural dolomite powder-embedded LHTESU and a HRS-assisted GDS with natural dolomite powder-embedded LHTESU. Designed and manufactured GDSs have been experimentally analysed under the same environmental conditions. According to the experimentally achieved findings, combined utilisation of HRS and dolomite powder in the LHTESU reduced the drying time approximately as 36.36%. Moreover, highest instantaneous outlet air temperature was achieved as 51.4 degrees C in the system that used natural dolomite-embedded LHTESU and HRS. The exergetic efficiency of the GDS was upgraded as 46.21% by using the mentioned modifications in comparison to the base case (the system contains only paraffin-based LHTESU). In addition, specific moisture extraction rate for the analysed GDSs was attained between 0.96 and 1.52 kg.kWh-1.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Experimental investigation of a double-flow photovoltaic/thermal air collector with natural dolomite powder-embedded thermal energy storage unit
    Gurbuz, Emine Yagiz
    Kusun, Baris
    Tuncer, Azim Dogus
    Ural, Tolga
    JOURNAL OF ENERGY STORAGE, 2023, 64
  • [2] Thermal energy use for dehumidification of a tomato greenhouse by natural ventilation and a system with an air-to-air heat exchanger
    Maslak, Katarzyna
    Nimmermark, Sven
    AGRICULTURAL AND FOOD SCIENCE, 2017, 26 (01) : 56 - 66
  • [3] Performance investigation on an air source heat pump system with latent heat thermal energy storage
    Lin, Ying
    Fan, Yubin
    Yu, Meng
    Jiang, Long
    Zhang, Xuejun
    Energy, 2022, 239
  • [4] Performance investigation on an air source heat pump system with latent heat thermal energy storage
    Lin, Ying
    Fan, Yubin
    Yu, Meng
    Jiang, Long
    Zhang, Xuejun
    ENERGY, 2022, 239
  • [5] Experimental Performance Analysis of a Solar Desalination System Modified with Natural Dolomite Powder Integrated Latent Heat Thermal Storage Unit
    Selimefendigil, Fatih
    Sirin, Ceylin
    Oztop, Hakan F.
    SUSTAINABILITY, 2022, 14 (05)
  • [6] Thermal performance of a pump-driven loop heat pipe as an air-to-air energy recovery device
    Zhou, Feng
    Duan, Wei
    Ma, Guoyuan
    ENERGY AND BUILDINGS, 2017, 151 : 206 - 216
  • [7] Improvement of Thermal Performance using Spineloxides/Water Nanofluids in the Heat Recovery Unit with Air-to-Air Thermosiphone Mechanism
    İpek Aytaç
    Adnan Sözen
    Kerim Martin
    Çağdaş Filiz
    Hafiz Muhammad Ali
    International Journal of Thermophysics, 2020, 41
  • [8] Improvement of Thermal Performance using Spineloxides/Water Nanofluids in the Heat Recovery Unit with Air-to-Air Thermosiphone Mechanism
    Aytac, Ipek
    Sozen, Adnan
    Martin, Kerim
    Filiz, Cagdas
    Ali, Hafiz Muhammad
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2020, 41 (11)
  • [9] Adequacy of air-to-air heat recovery ventilation system applied in low energy buildings
    El Fouih, Younness
    Stabat, Pascal
    Riviere, Philippe
    Phuong Hoang
    Archambault, Valerie
    ENERGY AND BUILDINGS, 2012, 54 : 29 - 39
  • [10] Experimental improvements of heat transfer in a latent heat thermal energy storage unit with embedded heat sources
    Lacroix, M
    Duong, T
    ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (08) : 703 - 716