Quantitative evaluation of the natural convection effect on thermal conductivity measurement with transient plane source method

被引:3
|
作者
Wu, Ke-Fan [1 ]
Cao, Tao-Feng [2 ]
Li, Wen-Bin [1 ]
Zhang, Hu [1 ]
Tang, Gui-Hua [3 ]
机构
[1] Xi An Jiao Tong Univ, Sch Aerosp Engn, State Key Lab Strength & Vibrat Mech Struct, Shaanxi Key Lab Environm & Control Flight Vehicle, Xian 710049, Peoples R China
[2] Xian Aerosp Solid Prop Technol Inst, Xian 710025, Peoples R China
[3] Xi An Jiao Tong Univ, Key Lab Thermofluid Sci & Engn, Minist Educ, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal conductivity; Transient plane source method; Natural convection; Quantitative study; HOT DISK SENSOR; TRANSPORT-PROPERTIES; TEMPERATURE; DIFFUSIVITY;
D O I
10.1016/j.csite.2023.102933
中图分类号
O414.1 [热力学];
学科分类号
摘要
When measuring the thermal conductivity of liquids with transient methods, natural convection occurs inevitably and whether it can be ignored is unknown. The quantitative deviation introduced by natural convection should be revealed clearly to ensure reliable experiment. In this study, the influence of natural convection is quantitatively evaluated in measuring the thermal conductivity of liquids with transient plane source method. By numerically mimicking the transient heat transfer process within liquids, the sensor temperature responses with neglecting and considering natural convection are obtained and used to calculate the corresponding thermal conductivity. The difference between them represents the quantitative influence introduced by natural convection. The effects of sensor orientation, heating time and heating power are compared for lead-bismuth eutectic alloy, GaInSn alloy, deionized water, molten salt, glycerol and cupric sulfate. Experiments are performed to verify the simulation. It is found that for the liquids with lower Prandtl number (<10), the thermal conductivity measured by horizontally placed sensor is more precise than that by vertically placed sensor. On the contrary, the liquids with Prandtl number higher than 1000 are less affected (<1%) by natural convection. Shorter heating time and proper temperature rise magnitude can suppress the influence of natural convection to some extent.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Analysis of radiation effect on thermal conductivity measurement of semitransparent materials based on transient plane source method
    Wang, Shuai
    Ai, Qing
    Zou, Tian-qi
    Sun, Chuang
    Xie, Ming
    [J]. APPLIED THERMAL ENGINEERING, 2020, 177
  • [2] Comparison of the new plane source method to the step wise transient method for thermal conductivity and diffusivity measurement
    Malinaric, Svetozar
    Elkholy, Ahmed
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 164
  • [3] Parameter Estimations on Measurement Accuracy for Thermal Conductivity of Wood Using the Transient Plane Source Method
    Meng, Hongxu
    Yu, Xinxin
    Chen, Bonan
    Ren, Pengyuan
    Zhao, Jingyao
    [J]. Forests, 2024, 15 (10):
  • [4] Thermal Conductivity of Thermal Interface Materials Evaluated By a Transient Plane Source Method
    Wang, Hsin
    Ihms, David W.
    Brandenburg, Scott D.
    Salvador, James R.
    [J]. JOURNAL OF ELECTRONIC MATERIALS, 2019, 48 (07) : 4697 - 4705
  • [5] Thermal Conductivity of Thermal Interface Materials Evaluated By a Transient Plane Source Method
    Hsin Wang
    David W. Ihms
    Scott D. Brandenburg
    James R. Salvador
    [J]. Journal of Electronic Materials, 2019, 48 : 4697 - 4705
  • [6] Sensitivity of the Transient Plane Source Method to Small Variations of Thermal Conductivity
    Sergejs Tarasovs
    Olga Bulderberga
    Daiva Zeleniakiene
    Andrey Aniskevich
    [J]. International Journal of Thermophysics, 2021, 42
  • [7] Sensitivity of the Transient Plane Source Method to Small Variations of Thermal Conductivity
    Tarasovs, Sergejs
    Bulderberga, Olga
    Zeleniakiene, Daiva
    Aniskevich, Andrey
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2021, 42 (12)
  • [8] Thermal conductivity of cellular metals measured by the transient plane source method
    Solorzano, E.
    Rodriguez-Perez, M. A.
    de Saja, J. A.
    [J]. ADVANCED ENGINEERING MATERIALS, 2008, 10 (06) : 596 - 602
  • [9] A single-sided method based on transient plane source technique for thermal conductivity measurement of liquids
    Ai, Qing
    Hu, Zhen-Wen
    Wu, Lin-Lin
    Sun, Feng-Xian
    Xie, Ming
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 109 : 1181 - 1190
  • [10] The measurement of the thermal conductivity of solid aggregates using the transient plane source technique
    Bouguerra, A
    Laurent, JP
    Goual, MS
    Queneudec, M
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (20) : 2900 - 2904