A comparison of bioelectrical impedance analysis and air displacement plethysmography to assess body composition in children

被引:2
|
作者
Chen, Fangfang [1 ]
Wu, Lijun [1 ]
Chen, Yiren [1 ]
Wang, Jing [2 ]
Liu, Junting [1 ]
Huang, Guimin [1 ]
Hou, Dongqing [1 ]
Liao, Zijun [1 ]
Zhang, Ting [1 ]
Xie, Xianghui [1 ]
Liu, Gongshu [2 ]
机构
[1] Capital Inst Pediat, Dept Epidemiol, Beijing, Peoples R China
[2] Tianjin Womens & Childrens Hlth Ctr, Tianjin, Peoples R China
关键词
bioelectrical impedance analysis; air displacement plethysmography; body composition; obesity; children; FAT MASS; WEIGHT;
D O I
10.3389/fpubh.2023.1164556
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
BackgroundAccurate assessment of body composition (BC) is important to investigate the development of childhood obesity. A bioelectrical impedance analysis (BIA) device is portable and inexpensive compared with air displacement plethysmography (ADP) for the assessment of BC and is widely used in children. However, studies of the effectiveness of BIA are few and present different results, especially in pediatric populations. The aim of this study was to evaluate the agreement between BIA and ADP for estimating BC. MethodsThe BC of 981 Chinese children (3-5 years) was measured using the BIA device (SeeHigher BAS-H, China) and ADP (BOD POD). ResultsOur results showed that BIA underestimated fat mass (FM) and overestimated fat-free mass (FFM) in normal weight children (P < 0.05), but the opposite trend was shown in children with obesity (P < 0.05). The agreement between FM and FFM measured by the two methods was strong (CCC > 0.80). The linear regression equation of 5-year-old children was constructed. ConclusionThe SeeHigher BAS-H multi-frequency BIA device is a valid device to evaluate BC in Chinese preschool children compared with ADP (BOD POD), especially in 5-year-old children or children with obesity. Further research is needed to standardize the assessment of BC in children.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A Comparison of Multi-frequency Bioelectrical Impedance and Air Displacement Plethysmography for Tracking Changes in Body Composition Following a 12-week Resistance Training Program
    Kern, Mark
    Morelli, Taylor
    Hernandez, Lisa M.
    Hobb, Kylee
    Clayton, Zach
    Schelechi, Mahshid
    Barber, Anjee
    Petrisko, Yumi
    Hooshmand, Shirin
    Nemoseck, Tricia
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 448 - 448
  • [32] Whole body air displacement plethysmography compared with hydrodensitometry for body composition analysis
    Dewit, O
    Fuller, NJ
    Fewtrell, MS
    Elia, M
    Wells, JCK
    ARCHIVES OF DISEASE IN CHILDHOOD, 2000, 82 (02) : 159 - 164
  • [33] Whole body composition analysis by the bodpod air-displacement plethysmography method in children with phenylketonuria
    Albersen, M.
    Bonthuis, M.
    De Roos, N. M.
    van den Hurk, T. A. M.
    Carbasisus-Weber, E. C.
    Hendriks, M. M. W. D.
    Koning, T. J.
    Visser, G.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2008, 31 : 81 - 81
  • [34] Can air-displacement plethysmography replace hydrodensitometry for body composition analysis in children and adults?
    Ellis, KJ
    Pratt, L
    Puyau, M
    Shypailo, R
    Butte, NF
    FASEB JOURNAL, 2001, 15 (05): : A1004 - A1004
  • [35] Body composition measurement in young children using quantitative magnetic resonance: a comparison with air displacement plethysmography
    Chen, L. -W.
    Tint, M. -T.
    Fortier, M. V.
    Aris, I. M.
    Shek, L. P. -C.
    Tan, K. H.
    Rajadurai, V. S.
    Gluckman, P. D.
    Chong, Y. -S.
    Godfrey, K. M.
    Kramer, M. S.
    Henry, C. J.
    Yap, F.
    Lee, Y. S.
    PEDIATRIC OBESITY, 2018, 13 (06): : 365 - 373
  • [36] Body Composition Using Air Displacement Plethysmography in Children With Inflammatory Bowel Disease
    Dhaliwal, Jasbir
    Martincevic, Inez
    Williams, Brock
    Frost, Karen
    Uusoue, Krista
    Arpino, Valerie
    Church, Peter
    Walters, Thomas D.
    Griffiths, Anne M.
    Mouzaki, Marialena
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2020, 71 (01): : 52 - 58
  • [37] A Comparison of Air Displacement Plethysmography and Bioimpedance Estimates of Body Composition in Young Adults
    Graham, Ralph E.
    Nelson, Jeff A.
    Queen, Brandon S.
    Scott, Dustin G.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S313 - S313
  • [38] Statistical validation of air-displacement plethysmography for body composition assessment in children
    Ittenbach, RF
    Buison, AM
    Stallings, VA
    Zemel, BS
    ANNALS OF HUMAN BIOLOGY, 2006, 33 (02) : 187 - 201
  • [39] Validation of air displacement plethysmography for assessing body composition
    Wagner, DR
    Heyward, VH
    Gibson, AL
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (07): : 1339 - 1344
  • [40] USE OF BIOELECTRICAL-IMPEDANCE ANALYSIS TO ASSESS BODY-COMPOSITION OF SEALS
    GALES, R
    RENOUF, D
    WORTHY, GAJ
    MARINE MAMMAL SCIENCE, 1994, 10 (01) : 1 - 12