A comparison of bioelectrical impedance analysis and air displacement plethysmography to assess body composition in children

被引:2
|
作者
Chen, Fangfang [1 ]
Wu, Lijun [1 ]
Chen, Yiren [1 ]
Wang, Jing [2 ]
Liu, Junting [1 ]
Huang, Guimin [1 ]
Hou, Dongqing [1 ]
Liao, Zijun [1 ]
Zhang, Ting [1 ]
Xie, Xianghui [1 ]
Liu, Gongshu [2 ]
机构
[1] Capital Inst Pediat, Dept Epidemiol, Beijing, Peoples R China
[2] Tianjin Womens & Childrens Hlth Ctr, Tianjin, Peoples R China
关键词
bioelectrical impedance analysis; air displacement plethysmography; body composition; obesity; children; FAT MASS; WEIGHT;
D O I
10.3389/fpubh.2023.1164556
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
BackgroundAccurate assessment of body composition (BC) is important to investigate the development of childhood obesity. A bioelectrical impedance analysis (BIA) device is portable and inexpensive compared with air displacement plethysmography (ADP) for the assessment of BC and is widely used in children. However, studies of the effectiveness of BIA are few and present different results, especially in pediatric populations. The aim of this study was to evaluate the agreement between BIA and ADP for estimating BC. MethodsThe BC of 981 Chinese children (3-5 years) was measured using the BIA device (SeeHigher BAS-H, China) and ADP (BOD POD). ResultsOur results showed that BIA underestimated fat mass (FM) and overestimated fat-free mass (FFM) in normal weight children (P < 0.05), but the opposite trend was shown in children with obesity (P < 0.05). The agreement between FM and FFM measured by the two methods was strong (CCC > 0.80). The linear regression equation of 5-year-old children was constructed. ConclusionThe SeeHigher BAS-H multi-frequency BIA device is a valid device to evaluate BC in Chinese preschool children compared with ADP (BOD POD), especially in 5-year-old children or children with obesity. Further research is needed to standardize the assessment of BC in children.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Comparison of Bioelectrical Impedance Analysis and Air Displacement Plethysmography
    Coufalova, Klara
    Komarc, Martin
    Cochrane, Darryl James
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2019, 37 (03): : 985 - 990
  • [2] Comparison of Air Displacement Plethysmography and Multi-Frequency Bioelectrical Impedance Analysis for Body Composition Assessment
    Gordon, Benjamin T.
    Arikawa, Andrea Y.
    Gerkens, Kristin
    Gonzalez, Andriana
    Boyd, Sara
    Baskin, Amber
    Bednarzyk, Michele
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 907 - 907
  • [3] A comparison of air displacement plethysmography and bioelectrical impedance analysis in overweight and obese children
    Radley, Duncan
    Griffiths, Claire
    Cooke, Carlton
    Mackreth, Peter
    Gately, Paul
    INTERNATIONAL JOURNAL OF OBESITY, 2007, 31 : S110 - S110
  • [4] Comparing Bioelectrical Impedance Analysis To Air Displacement Plethysmography For Body Composition Assessment In Female Athletes
    Katona, Austin
    Riewe, Caroline
    Zalewski, Samantha
    Powers, Kelly
    Mangine, Robert
    Peairs, Abigail
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 184 - 185
  • [5] Comparison of air-displacement plethysmography with hydrostatic weighing and bioelectrical impedance analysis for the assessment of body composition in healthy adults
    Biaggi, RR
    Vollman, MW
    Nies, MA
    Brener, CE
    Flakoll, PJ
    Levenhagen, DK
    Sun, M
    Karabulut, Z
    Chen, KY
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1999, 69 (05): : 898 - 903
  • [6] Body Composition Analysis Comparison between Air Displacement Plethysmography and Direct Segmental Bioelectrical Impedance in a University Student Population
    Johnson, Kent D.
    Luedtke, Catherine
    Romeo, Frankie
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 992 - 993
  • [7] Air Displacement Plethysmography Versus Bioelectrical Impedance to Determine Body Composition in Pediatric Hemodialysis Patients
    Vega, Molly Wong
    Srivaths, Poyyapakkam R.
    JOURNAL OF RENAL NUTRITION, 2017, 27 (06) : 439 - 444
  • [8] Calibration of bioelectrical impedance analysis for body composition assessment in Ethiopian infants using air-displacement plethysmography
    R Wibæk
    P Kæstel
    S R Skov
    D L Christensen
    T Girma
    J C K Wells
    H Friis
    G S Andersen
    European Journal of Clinical Nutrition, 2015, 69 : 1099 - 1104
  • [9] Calibration of bioelectrical impedance analysis for body composition assessment in Ethiopian infants using air-displacement plethysmography
    Wibaek, R.
    Kaestel, P.
    Skov, S. R.
    Christensen, D. L.
    Girma, T.
    Wells, J. C. K.
    Friis, H.
    Andersen, G. S.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2015, 69 (10) : 1099 - 1104
  • [10] Comparison of Body Composition Measurement With Whole Body Multifrequency Bioelectrical Impedance and Air Displacement Plethysmography in Healthy Middle-Aged Women
    Benton, Melissa J.
    Swan, Pamela D.
    Schlairet, Maura C.
    Sanderson, Sonya
    HEALTH CARE FOR WOMEN INTERNATIONAL, 2011, 32 (12) : 1068 - 1078