Live stream of prehospital point-of-care ultrasound during cardiopulmonary resuscitation - A feasibility trial

被引:2
|
作者
Hafner, C. [1 ]
Manschein, V. [1 ,2 ]
Klaus, D. A. [1 ]
Schaubmayr, W. [1 ]
Tiboldi, A. [1 ]
Scharner, V. [1 ]
Gleiss, A. [3 ]
Thal, B. [4 ]
Krammel, M. [5 ]
Hamp, T. [1 ,4 ]
Willschke, H. [1 ,2 ]
Hermann, M. [1 ,2 ,6 ]
机构
[1] Med Univ Vienna, Dept Anaesthesia Intens Care Med & Pain Med, Div Gen Anaesthesia & Intens Care Med, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Ludwig Boltzmann Inst Digital Hlth & Patient Safet, Waehringer Str 104-10, A-1180 Vienna, Austria
[3] Med Univ Vienna, Ctr Med Data Sci, Spitalgasse 23, A-1090 Vienna, Austria
[4] Emergency Med Serv Vienna, Radetzkystr 1, A-1030 Vienna, Austria
[5] PULS Austrian Cardiac Arrest Awareness Assoc, Lichtenthaler Gasse 4-1-R03, A-1090 Vienna, Austria
[6] Med Univ Vienna, Dept Anaesthesia Intens Care Med & Pain Med, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
CARDIAC-ARREST; LIFE-SUPPORT; EMERGENCY; GUIDELINES; ECHO;
D O I
10.1016/j.resuscitation.2023.110089
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Current resuscitation guidelines recommend that skilled persons could use ultrasound to detect reversible causes during cardiopulmonary resuscitation (CPR) where the examination can be safely integrated into the Advanced Life Support (ALS) algorithm. However, in a prehospital setting performing and rapidly interpreting ultrasound can be challenging for physicians. Implementing remote, expert-guided, and real-time transmissions of ultrasound examinations offers the opportunity for tele-support, even during an out-of-hospital cardiac arrest (OHCA). The aim of this feasibility study was to evaluate the impact of tele-supported ultrasound in ALS on hands-off time during an OHCA. Methods: In an urban setting, physicians performed point-of-care ultrasound (POCUS) on patients during OHCA using a portable device, either with tele-support (n = 30) or without tele-support (n = 12). Where tele-support was used, the ultrasound image was transmitted via a remote real-time connection to an on-call specialist in anaesthesia and intensive care medicine with an advanced level of critical care ultrasound expertise. The primary safety endpoint of this study was to evaluate whether POCUS can be safely integrated into the algorithm, and to provide an analysis of handsoff time before, during, and after POCUS during OHCA. Results: In all 42 cases it was possible to perform POCUS during regular rhythm analyses, and no additional hands-off time was required. In 40 of these 42 cases, the physicians were able to perform POCUS during a single regular rhythm analysis, with two periods required only in two cases. The median hands-off time during these rhythm analyses for POCUS with tele-support was 10 (8-13) seconds, and 11 (9-14) seconds for POCUS without tele-support. Furthermore, as a result of POCUS, in a quarter of all cases the physician on scene altered their diagnosis of the primary suspected cause of cardiac arrest, leading to a change in treatment strategy. Conclusions: This feasibility study demonstrated that POCUS with tele-support can be safely performed during OHCA in an urban environment. Trial Registration (before patient enrolment): ClinicalTrials.gov, NCT04817475.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Randomized Controlled Trial of Point-of-Care Ultrasound Education for the Recognition of Tension Pneumothorax by Paramedics in Prehospital Simulation
    Khalil, Paul A.
    Merelman, Andrew
    Riccio, John
    Peterson, Jodi
    Shelton, Ryan
    Meyers, Jeff
    Ketchmark, Tim
    Garneau, Emily
    Khalil, Stephanie
    Roosevelt, Genie
    Toney, Amanda
    PREHOSPITAL AND DISASTER MEDICINE, 2021, 36 (01) : 74 - 78
  • [22] Point-of-care laboratory analyses of intraosseous, arterial and central venous samples during experimental cardiopulmonary resuscitation
    Jousi, Mille
    Skrifvars, Markus B.
    Nelskyla, Annika
    Ristagno, Giuseppe
    Schramko, Alexey
    Nurmi, Jouni
    RESUSCITATION, 2019, 137 : 124 - 132
  • [23] Impact of serial cardiopulmonary point-of-care ultrasound exams in patients with acute dyspnoea: a randomised, controlled trial
    Arvig, Michael Dan
    Lassen, Annmarie Touborg
    Gaede, Peter Haulund
    Gartner, Stefan Wernblad
    Falster, Casper
    Skov, Inge Raadal
    Petersen, Henrik Omark
    Posth, Stefan
    Laursen, Christian B.
    EMERGENCY MEDICINE JOURNAL, 2023, 40 (10) : 700 - 707
  • [24] Point-of-care ultrasound use in patients with cardiac arrest is associated prolonged cardiopulmonary resuscitation pauses: A prospective cohort study
    Clattenburg, Eben J.
    Wroe, Peter
    Brown, Stephen
    Gardner, Kevin
    Losonczy, Lia
    Singh, Amandeep
    Nagdev, Arun
    RESUSCITATION, 2018, 122 : 65 - 68
  • [25] Point-of-Care Ultrasound
    Linda Lee
    Jeanne M. DeCara
    Current Cardiology Reports, 2020, 22
  • [26] Point-of-Care Ultrasound
    Lee, Linda
    DeCara, Jeanne M.
    CURRENT CARDIOLOGY REPORTS, 2020, 22 (11)
  • [27] Experience with pulse oximetry during prehospital cardiopulmonary resuscitation
    Stratmann, B
    Richter, J
    Muhr, G
    UNFALLCHIRURG, 1997, 100 (06): : 465 - 468
  • [28] Artificial intelligence-based evaluation of carotid artery compressibility via point-of-care ultrasound in determining the return of spontaneous circulation during cardiopulmonary resuscitation
    Park, Subin
    Yoon, Hee
    Kang, Soo Yeon
    Jo, Ik Joon
    Heo, Sejin
    Chang, Hansol
    Park, Jong Eun
    Lee, Guntak
    Kim, Taerim
    Hwang, Sung Yeon
    Park, Soyoung
    Chung, Myung Jin
    RESUSCITATION, 2024, 202
  • [29] Prehospital and emergency department care to preserve neurologic function during and following cardiopulmonary resuscitation
    Ornato, JP
    Peberdy, MA
    NEUROLOGIC CLINICS, 2006, 24 (01) : 23 - +
  • [30] Change in Intraocular Pressure During Point-of-Care Ultrasound
    Berg, Cameron
    Doniger, Stephanie J.
    Zaia, Brita
    Williams, Sarah R.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2015, 16 (02) : 263 - 268