Effectiveness of ambulatory non-invasive fetal electrocardiography: impact of maternal and fetal characteristics

被引:9
|
作者
Liu, Becky [1 ,2 ]
Thilaganathan, Basky [1 ,2 ]
Bhide, Amar [1 ,2 ,3 ]
机构
[1] St Georges Univ Hosp NHS Fdn Trust, Fetal Med Unit, London, England
[2] St Georges Univ London, Mol & Clin Sci Res Inst, Vasc Biol Res Ctr, London, England
[3] St Georges Univ Hosp NHS Fdn Trust, Dept Obstet & Gynaecol, Fetal Med Unit, Blackshaw Rd, London SW17 0QT, England
关键词
ambulatory monitoring; computerized cardiotocography; fetal heart rate monitoring; non-invasive fetal electrocardiography; signal loss; signal quality; BODY-MASS INDEX; CARDIOTOCOGRAM; QUALITY;
D O I
10.1111/aogs.14543
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
IntroductionNon-invasive fetal electrocardiography (NIFECG) has potential benefits over the computerized cardiotocography (cCTG) that may permit its development in remote fetal heart-rate monitoring. Our study aims to compare signal quality and heart-rate detection from a novel self-applicable NIFECG monitor against the cCTG, and evaluate the impact of maternal and fetal characteristics on both devices. Material and methodsThis prospective observational study took place in a university hospital in London. Women with a singleton pregnancy from 28 + 0 weeks' gestation presenting for cCTG were eligible. Concurrent monitoring with both NIFECG and cCTG were performed for up to 60 minutes. Post-processing of NIFECG produced signal loss, computed in both 0.25 (E240)- and 3.75 (E16)-second epochs, and fetal heart-rate and maternal heart-rate values. cCTG signal loss was calculated in 3.75-second epochs. Accuracy and precision analysis of 0.25-second epochal fetal heart-rate and maternal heart-rate were compared between the two devices. Multiple regression analyses were performed to assess the impact of maternal and fetal characteristics on signal loss. Identifier: NCT04941534. Results285 women underwent concurrent monitoring. For fetal heart-rate, mean bias, precision and 95% limits of agreement were 0.1 beats per minute (bpm), 4.5 bpm and -8.7 bpm to 8.8 bpm, respectively. For maternal heart-rate, these results were -0.4 bpm, 3.3 bpm and -7.0 to 6.2 bpm, respectively. Median NIFECG E240 and E16 signal loss was 32.0% (interquartile range [IQR] 6.5%-68.5%) and 17.3% (IQR 1.8%-49.0%), respectively. E16 cCTG signal loss was 1.0% (IQR 0.0%-3.0%). For NIFECG, gestational age was negatively associated with signal loss (beta = -2.91, 95% CI -3.69 to -2.12, P < 0.001). Increased body mass index, fetal movements and lower gestational age were all associated with cCTG signal loss (beta = 0.30, 95% CI 0.17-0.43, P < 0.001; beta = 0.03, 95% CI 0.01-0.05, P = 0.014; and beta = -0.28, 95% CI -0.51 to -0.05, P = 0.017, respectively). ConclusionsAlthough NIFECG is complicated by higher signal loss, it does not appear to be influenced by increased body mass index or fetal movement. NIFECG signal loss varies according to method of computation, and standards of signal acceptability need to be defined according to the ability of the device to produce clinically reliable physiological indices. The high accuracy of heart-rate indices is promising for NIFECG usage in the remote setting.
引用
收藏
页码:577 / 584
页数:8
相关论文
共 50 条
  • [11] Template subtraction based methods for non-invasive fetal electrocardiography extraction
    Rene Jaros
    Eva Tomicova
    Radek Martinek
    Scientific Reports, 14
  • [12] An Analog-Front-End for Non-Invasive Fetal Electrocardiography Monitoring
    John, Sachin Tom
    Muduli, Priya Ranjan
    Mukherjee, Anirban
    PROCEEDINGS OF THE 2016 IEEE STUDENTS' TECHNOLOGY SYMPOSIUM (TECHSYM), 2016, : 212 - 217
  • [13] A Novel Tool for Non-Invasive Fetal Electrocardiography Research: the NInFEA Dataset
    Sulas, Eleonora
    Pili, Giulia
    Gusai, Elisa
    Baldazzi, Giulia
    Urru, Monica
    Tumbarello, Roberto
    Raffo, Luigi
    Pani, Danilo
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5631 - 5634
  • [14] Influence of System Configuration on the Quality of Non-Invasive Fetal Electrocardiography Measurement
    Brablik, Jindrich
    Kahankova, Radana
    Martinek, Radek
    IFAC PAPERSONLINE, 2019, 52 (27): : 421 - 426
  • [15] An Integrated Framework for Assessing the Quality of Non-invasive Fetal Electrocardiography Signals
    Zhang, Yuwei
    Gu, Aihua
    Xiao, Zhijun
    Ma, Caiyun
    Wang, Zhongyu
    Zhao, Lina
    Yang, Chenxi
    Li, Jianqing
    Liu, Chengyu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (01) : 114 - 126
  • [16] Template subtraction based methods for non-invasive fetal electrocardiography extraction
    Jaros, Rene
    Tomicova, Eva
    Martinek, Radek
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [17] Non-invasive fetal monitoring using electrocardiography and phonocardiography: A preliminary study
    Gobillot, S.
    Fontecave-Jallon, J.
    Equy, V.
    Rivet, B.
    Gumery, P. Y.
    Hoffmann, P.
    JOURNAL OF GYNECOLOGY OBSTETRICS AND HUMAN REPRODUCTION, 2018, 47 (09) : 455 - 459
  • [18] Prenatal diagnosis of long QT syndrome by non-invasive fetal electrocardiography
    Fujimoto, Yoshinobu
    Matsumoto, Tadashi
    Honda, Nobuhisa
    Tojo, Ryuichiro
    Furuya, Masataka
    Kasai, Kenji
    Saito, Suguru
    Mochimaru, Fumio
    Ishikawa, Yasuhiro
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2009, 35 (03) : 555 - 561
  • [19] An Integrated Framework for Assessing the Quality of Non-invasive Fetal Electrocardiography Signals
    Yuwei Zhang
    Aihua Gu
    Zhijun Xiao
    Caiyun Ma
    Zhongyu Wang
    Lina Zhao
    Chenxi Yang
    Jianqing Li
    Chengyu Liu
    Journal of Medical and Biological Engineering, 2024, 44 : 114 - 126
  • [20] Comparison of short-term variation derived from ambulatory non-invasive fetal electrocardiography with computerised cardiotocography
    Liu, Becky
    Thilaganathan, Basky
    Bhide, Amar
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2023, 130 : 20 - 21