Quality control tests on the new front-end electronics for the Schwarzschild-Couder Telescope

被引:1
|
作者
Aramo, C. [1 ]
Bissaldi, E. [2 ,3 ]
Bitossi, M. [4 ]
Bonavolonta, C. [1 ]
De Robertis, G. [3 ]
Di Venere, L. [2 ,3 ]
Giordano, F. [2 ,3 ]
Incardona, S. [5 ,6 ]
Licciulli, F. [3 ]
Loporchio, S. [3 ]
Marsella, G. [5 ,6 ]
Pantaleo, F. R. [2 ,3 ]
Paoletti, R. [4 ,7 ]
Tripodi, G. [5 ,6 ]
机构
[1] INFN Sez Napoli, I-80126 Naples, Italy
[2] Univ & Politecn Bari, Dipartimento Interateneo Fis, I-70126 Bari, Italy
[3] INFN Sez Bari, I-70125 Bari, Italy
[4] INFN Sez Pisa, I-56127 Pisa, Italy
[5] Univ Palermo, Dipartimento Fis & Chim E Segre, viale Sci, I-90128 Palermo, Italy
[6] INFN Sez Catania, I-95123 Catania, Italy
[7] Univ Siena, Dipartimento Sci Fis Terra & Ambiente, I-53100 Siena, Italy
关键词
Test bench; Front-end electronics; Quality control test;
D O I
10.1016/j.nima.2022.167605
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
One of the proposed Medium-Sized Telescopes for the Cherenkov Telescope Array is the dual mirror optics Schwarzschild-Couder Telescope (SCT). The prototype SCT camera is currently equipped with 24 SiPM modules each one made of 64 pixels. The upgrade of the current camera is in progress, with the aim of fully equipping the 177 SiPM modules. A new front-end electronics is being developed and tested in order to improve the noise performance and match CTA requirements. In this process, 11328 SiPMs and the related electronics will be tested in the laboratories before the assembly on the telescope camera. The SiPM Multichannel ASIC for high Resolutions Cherenkov Telescope (SMART) has been developed by INFN to amplify the SiPM signals to be digitized and inserted in the trigger logic based on the TeV Array with GSa/s sampling and Experimental Trigger Application Specific Integrated Circuit (TARGET ASICs). An experimental setup has been devised to test about 750 SMART, which will be used to equip the full camera of the prototype SCT. Each SMART was tested for proper operation in response to a laser pulse. In this contribution we present a detailed scheme of the test bench and the first results obtained on the quality control measurements.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] LHC front-end electronics
    Hall, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (1-2): : 353 - 364
  • [32] The Muon Front-End Control Electronics of the LHCb Experiment
    Bocci, Valerio
    Chiodi, Giacomo
    Iacoangeli, Francesco
    Messi, Francesco
    Nobrega, Rafael A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (06) : 3807 - 3814
  • [33] Front-End Electronics Control and Monitoring for the LHCb Upgrade
    Barbosa, Joao
    Alessio, Federico
    Cardoso, Luis
    Gaspar, Clara
    Durante, Paolo
    23RD INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2018), 2019, 214
  • [34] FAZIA front-end electronics
    Salomon, F.
    Edelbruck, P.
    Brulin, G.
    Boiano, A.
    Tortone, G.
    Ordine, A.
    Bini, M.
    Barlini, S.
    Valdre, S.
    IWM-EC 2014 - INTERNATIONAL WORKSHOP ON MULTI FACETS OF EOS AND CLUSTERING, 2015, 88
  • [35] Characterization and assembly of near-ultraviolet SiPMs for the Schwarzschild-Couder medium-size telescope proposed for the CTA Observatory
    Adams, C.
    Ambrosi, G.
    Ambrosio, M.
    Aramo, C.
    Benbow, W.
    Bertucci, B.
    Bissaldi, E.
    Bitossi, M.
    Boiano, A.
    Bonavolonta, C.
    Bose, R.
    Brill, A.
    Buckley, J. H.
    Caprai, M.
    Covault, C. E.
    Di Venere, L.
    Feng, Q.
    Fiandrini, E.
    Gent, A.
    Giglietto, N.
    Giordano, F.
    Halliday, R.
    Hervet, O.
    Hughes, G.
    Humensky, T. B.
    Ionica, M.
    Jin, W.
    Kaaret, P.
    Kieda, D.
    Kim, B.
    Licciulli, F.
    Loporchio, S.
    Masone, V.
    Meures, T.
    Mode, B. A. W.
    Mukherjee, R.
    Okumura, A.
    Otte, N.
    Pantaleo, F. R.
    Paoletti, R.
    Petrashyk, A.
    Powell, J.
    Powell, K.
    Ribeiro, D.
    Rousselle, J.
    Rugliancich, A.
    Santander, M.
    Shang, R.
    Stevenson, B.
    Stiaccini, L.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXI, 2019, 11114
  • [36] Design of new front-end electronics for animal PET
    Deng, Z
    Yeom, JY
    Ishitsu, T
    Nakazawa, M
    Takahashi, H
    Murayama, H
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1543 - 1546
  • [37] A new front-end electronics chain for timing RPCs
    Blanco, A
    Carolino, N
    Fonte, P
    Gobbi, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1249 - 1253
  • [38] The Analog Ring Sampler: An ASIC for the front-end electronics of the ANTARES neutrino telescope
    Druillole, F
    Lachartre, D
    Feinstein, F
    Fopma, J
    Delagnes, E
    Lafoux, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1122 - 1129
  • [39] High Performances and Low Cost Front-End Electronics for the Cherenkov Telescope Array
    Vincent, P.
    Bitossi, M.
    Delagnes, E.
    Feinstein, F.
    Gascon, D.
    Glicenstein, J. -F.
    Hermann, G.
    Nayman, P.
    Paoletti, R.
    Pegna, R. G.
    Toussenel, F.
    HIGH ENERGY GAMMA-RAY ASTRONOMY, 2009, 1085 : 890 - +
  • [40] The analogue ring sampler: An ASIC front-end electronics of the ANTARES neutrino telescope
    Druillole, F
    Lachartre, D
    Feinstein, F
    Delagnes, E
    Lafoux, H
    Hadamache, C
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 138 - 142