Comparison of Administrative versus Electronic Health Record-based Methods for Identifying Sepsis Hospitalizations

被引:5
|
作者
Karlic, Kevin J. [1 ]
Clouse, Tori L. [1 ]
Hogan, Cainnear K. [2 ]
Garland, Allan [3 ]
Seelye, Sarah [2 ]
Sussman, Jeremy B. [1 ,2 ]
Prescott, Hallie C. [1 ,2 ]
机构
[1] Univ Michigan, Dept Internal Med, Ann Arbor, MI USA
[2] Vet Affairs Ctr Clin Management Res, Ann Arbor, MI USA
[3] Univ Manitoba, Dept Med, Winnipeg, MB, Canada
关键词
sepsis; health services research; quality improvement; DEFINITIONS; FRAMEWORK; MORTALITY;
D O I
10.1513/AnnalsATS.202302-105OC
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Rationale: Despite the importance of sepsis surveillance, no optimal approach for identifying sepsis hospitalizations exists. The Centers for Disease Control and Prevention Adult Sepsis Event Definition (CDC-ASE) is an electronic medical record-based algorithm that yields more stable estimates over time than diagnostic coding-based approaches but may still result in misclassification. Objectives: We sought to assess three approaches to identifying sepsis hospitalizations, including a modified CDC-ASE. Methods: This cross-sectional study included patients in the Veterans Affairs Ann Arbor Healthcare System admitted via the emergency department (February 2021 to February 2022) with at least one episode of acute organ dysfunction within 48 hours of emergency department presentation. Patients were assessed for community-onset sepsis using three methods: 1) explicit diagnosis codes, 2) the CDC-ASE, and 3) a modified CDC-ASE. The modified CDC-ASE required at least two systemic inflammatory response syndrome criteria instead of blood culture collection and had a more sensitive definition of respiratory dysfunction. Each method was compared with a reference standard of physician adjudication via medical record review. Patients were considered to have sepsis if they had at least one episode of acute organ dysfunction graded as "definitely" or "probably" infection related on physician review. Results: Of 821 eligible hospitalizations, 449 were selected for physician review. Of these, 98 (21.8%) were classified as sepsis by medical record review, 103 (22.9%) by the CDC-ASE, 132 (29.4%) by the modified CDC-ASE, and 37 (8.2%) by diagnostic codes. Accuracy was similar across the three methods of interest (80.6% for the CDC-ASE, 79.6% for the modified CDC-ADE, and 84.2% for diagnostic codes), but sensitivity and specificity varied. The CDC-ASE algorithm had sensitivity of 58.2% (95% confidence interval [CI], 47.2-68.1%) and specificity of 86.9% (95% CI, 82.9-90.2%). The modified CDC-ASE algorithm had greater sensitivity (69.4% [95% CI, 59.3-78.3%]) but lower specificity (81.8% [95% CI, 77.3-85.7%]). Diagnostic codes had lower sensitivity (32.7% [95% CI, 23.5-42.9%]) but greater specificity (98.6% [95% CI, 96.7-99.55%]). Conclusions: There are several approaches to identifying sepsis hospitalizations for surveillance that have acceptable accuracy. These approaches yield varying sensitivity and specificity, so investigators should carefully consider the test characteristics of each method before determining an appropriate method for their intended use.
引用
收藏
页码:1309 / 1315
页数:7
相关论文
共 50 条
  • [21] Blood Culture Ordering After Sepsis Alerts and Subsequent Patient Outcomes: An Electronic Health Record-Based Study
    Li, Ling
    Rathnayake, Kasun
    Walter, Scott
    Fullick, Mary
    Shetty, Amith
    Hudson, Paul
    Lander, Harvey
    Westbrook, Johanna I.
    MEDINFO 2023 - THE FUTURE IS ACCESSIBLE, 2024, 310 : 314 - 318
  • [22] DESIGN OF AN ELECTRONIC MEDICAL RECORD-BASED ALERT SYSTEM TO DETECT THE ONSET OF SEVERE SEPSIS
    Fountain, Stephanie
    Perry, James, III
    Stoffer, Brenda
    Raschke, Robert
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [23] A narrative review on the validity of electronic health record-based research in epidemiology
    Milena A. Gianfrancesco
    Neal D. Goldstein
    BMC Medical Research Methodology, 21
  • [24] EARLY DETECTION OF PEDIATRIC SEPSIS USING AN ELECTRONIC MEDICAL RECORD-BASED SCREENING TOOL
    Salomon, Jeffrey
    Serrao, Karl
    Guardiola, Jose
    Bonura, Amanda
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [25] Implementing Electronic Health Record-Based Quality Measures for Developmental Screening
    Jensen, Roxanne E.
    Chan, Kitty S.
    Weiner, Jonathan P.
    Fowles, Jinnet B.
    Neale, Shannon M.
    PEDIATRICS, 2009, 124 (04) : E648 - E654
  • [26] Bias of Inaccurate Disease Mentions in Electronic Health Record-based Phenotyping
    Kagawa, Rina
    Shinohara, Emiko
    Imari, Takeshi
    Kawazoe, Yoshimasa
    Ohe, Kazuhiko
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2019, 124 : 90 - 96
  • [27] Electronic health record-based surveillance of diagnostic errors in primary care
    Singh, Hardeep
    Giardina, Traber Davis
    Forjuoh, Samuel N.
    Reis, Michael D.
    Kosmach, Steven
    Khan, Myrna M.
    Thomas, Eric J.
    BMJ QUALITY & SAFETY, 2012, 21 (02) : 93 - 100
  • [28] Comparison of Electronic Health Record-Based and Claims-Based Diabetes Care Quality Measures: Causes of Discrepancies
    Laws, Michael Barton
    Michaud, Joanne
    Shield, Renee
    McQuade, William
    Wilson, Ira B.
    HEALTH SERVICES RESEARCH, 2018, 53 : 2988 - 3006
  • [29] Electronic health record-based patient tracking by emergency medicine physicians
    Villalba, Constanza
    Burke, Ryan C.
    Gurley, Kiersten
    Dhaliwal, Gurpreet
    Grossman, Shamai
    AEM EDUCATION AND TRAINING, 2022, 6 (02)
  • [30] Pharmacist Hypertension Management Using an Electronic Health Record-Based Approach
    Soreide, Kristin K.
    Solomon, Octavia
    Farhat, Nada M.
    Kolander, Sarah
    Gottschall, Terry
    George, Diane L.
    Szandzik, Edward G.
    Kalus, James S.
    Thomas, Emily
    AMERICAN JOURNAL OF MANAGED CARE, 2022, 28 (04): : E121 - E125