Effect of different metal-backed waveguides on amplified spontaneous emission

被引:0
|
作者
张波 [1 ]
侯延冰 [1 ]
娄志东 [1 ]
滕枫 [1 ]
刘小君 [1 ]
胡兵 [1 ]
孟令川 [1 ]
武文彬 [1 ]
机构
[1] Key Laboratory of Luminescence and Optical Information,Ministry of Education,Institute of Optoelectronic Technology, Beijing Jiaotong University
基金
中国国家自然科学基金;
关键词
polymer semiconductor; amplified spontaneous emission; electrode;
D O I
暂无
中图分类号
TN814 [波导、波导管、波导传输线];
学科分类号
0810 ; 081001 ;
摘要
We investigate the effect of a metallic electrode on the ability for poly[2-methoxy-5-(2’-ethylhexyloxy)-1,4phenylene vinylene](MEH-PPV) film to undergo amplified spontaneous emission(ASE).The threshold of the device with Ag cladding is about 10 times greater than that of a metal-free device,but metal such as Al completely shuts off ASE.The ASE recurs when a thin spacer layer,such as a few nanometers of SiO 2,is introduced between the MEH-PPV film and the Al cladding.Compared with the Cu or Al electrode,the Ag cladding is most suited to serve as an electrode with its low optical loss due to its high work-function and reflectivity.
引用
收藏
页码:288 / 292
页数:5
相关论文
共 50 条
  • [31] FURTHER OBSERVATIONS ON METAL-BACKED PATELLAR COMPONENT FAILURE
    BAYLEY, JC
    SCOTT, RD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (236) : 82 - 87
  • [32] Analysis and Design of a Metal-Backed RFID Tag Antenna
    Elboushi, Ayman
    Haraz, Osama
    Jamil, K.
    Sebak, Abdel-Razik
    2015 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2015, : 1572 - 1573
  • [33] AMPLIFIED SPONTANEOUS EMISSION
    WILLIS, CR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (12): : 1403 - &
  • [34] EVALUATION OF THE EFFECT OF THE FEMORAL ARTICULAR SURFACE MATERIAL ON THE WEAR OF A METAL-BACKED PATELLAR COMPONENT
    MILLIANO, MT
    WHITESIDE, LA
    KAISER, AD
    ZWIRKOSKI, PA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (287) : 178 - 186
  • [35] THE USE OF METAL-BACKED PATELLAR PROSTHESES IN TOTAL KNEE ARTHROPLASTY
    LASKIN, RS
    BUCKNELL, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (260) : 52 - 55
  • [36] SECONDARY DIFFRACTION OF A PLAN WAVE BY A METAL-BACKED DIELECTRIC STRIP
    BUYUKAKSOY, A
    UZGOREN, G
    JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 1990, 4 (04) : 297 - 309
  • [37] Damage mechanics of electronics on metal-backed substrates in harsh environments
    Lall, P
    Islam, MN
    Evans, J
    Suhling, JC
    Shete, T
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2006, 29 (01): : 204 - 212
  • [38] METAL-BACKED ACETABULAR CUPS IN TOTAL HIP-ARTHROPLASTY
    RITTER, MA
    KEATING, EM
    FARIS, PM
    BRUGO, G
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (05): : 672 - 677
  • [39] METAL-BACKED CERAMIC SHELL MOLDS FOR STEEL CASTINGS.
    Borisik, A.Ya.
    Mel'nikov, A.T.
    Liventsev, V.E.
    Uvarov, B.I.
    Soviet Castings Technology (English Translation of Liteinoe Proizvodstvo), 1986, (12): : 60 - 61
  • [40] Technique for acetabular liner revision in a nonmodular metal-backed component
    LaPorte, DM
    Mont, MA
    Pierre-Jacques, H
    Peyton, RS
    Hungerford, DS
    JOURNAL OF ARTHROPLASTY, 1998, 13 (03): : 348 - 350