Assessment of the accuracy of real-time continuous glucose monitoring system and its correlated factors

被引:0
|
作者
洛佩 [1 ]
机构
[1] Graduate Brigade,3rd Milit Med Univ
关键词
MBG; CGM; Assessment of the accuracy of real-time continuous glucose monitoring system and its correlated factors; MAGE; real; time;
D O I
暂无
中图分类号
R587.1 [糖尿病];
学科分类号
1002 ; 100201 ;
摘要
Objective To assess the factors that influence the accuracy of real-time continuous glucose monitoring system(RT-CGM).Methods A total of 79 diabetic patients wore RT-CGM for three days continuously while calibrating by interphalangeal glucose values 4-8 times a day.We counted matching rate of interphalangeal glucose values and RT-CGM probe value,and analyzed correlation of the matching rate with MAGE,SDBG,MBG,AUC10,AUC3.9,and NGE by Pearson correlation analysis and multiple linear
引用
收藏
页码:19 / 19
页数:1
相关论文
共 50 条
  • [21] The accuracy and efficacy of Real-Time Continuous Glucose Monitoring sensor in patients with type 1 diabetes
    Mastrototaro, John
    Shin, John
    Marcus, Alan
    Sulur, Giri
    DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 (05) : 385 - 390
  • [22] Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring (CGM) System during Elective Abdominal Surgery
    Tripyla, Afroditi
    Herzig, David
    Nakas, Christos
    Dehais, Joachim
    Andreou, Andreas
    Amiet, Franziska
    Gloor, Beat
    Vogt, Andreas
    Bally, Lia
    DIABETES, 2020, 69
  • [23] First experiences with the continuous real-time glucose monitoring system (Guardian REAL-time CGMS) in a cat with Diabetes mellitus
    Moretti, S.
    Zini, E.
    Tschuor, F.
    Reusch, C. E.
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 2009, 151 (01): : 27 - 30
  • [24] ACCURACY ASSESSMENT OF REAL-TIME CONTINUOUS GLUCOSE MONITORS IN CRITICALLY ILL PATIENTS: PRELIMINARY RESULTS
    Lorencio, C.
    Leal, Y. T.
    Bonet, A.
    Vehi, J.
    Bondia, J.
    Tache, A.
    Sirvent, J. M.
    INTENSIVE CARE MEDICINE, 2010, 36 : S217 - S217
  • [25] New perspectives on real-time continuous glucose monitoring Comment
    Stechova, Katerina
    LANCET CHILD & ADOLESCENT HEALTH, 2021, 5 (04): : 235 - 236
  • [26] Real-time continuous glucose monitoring: proven clinical indiciations
    Gomez Peralta, Fernando
    Abreu Padin, Cristina
    AVANCES EN DIABETOLOGIA, 2011, 27 (06): : 198 - 203
  • [27] DIABETES Under Control Real-Time Continuous Glucose Monitoring
    Ramchandani, Neesha
    Saadon, Yael
    Jornsay, Donna
    AMERICAN JOURNAL OF NURSING, 2010, 110 (04) : 60 - 63
  • [28] Is reimbursement for alerts and real-time continuous glucose monitoring needed?
    Norgaard, Kirsten
    Schmidt, Signe
    LANCET, 2021, 397 (10291): : 2230 - 2232
  • [29] Design and implementation of real-time continuous glucose monitoring instrument
    实时动态血糖监测器的设计与实现
    Liu, Hongying (liu_hongying@163.com), 2017, West China Hospital, Sichuan Institute of Biomedical Engineering (34):
  • [30] Sustainable Use of a Real-Time Continuous Glucose Monitoring System from 2018 to 2020
    van der Linden, Joost
    Welsh, John B.
    Walker, Tomas C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (07) : 508 - 511