Mathematic modeling on flexible cooling system in hot strip mill

被引:0
|
作者
彭良贵 [1 ]
刘相华 [1 ]
赵宪明 [1 ]
吴迪 [1 ]
机构
[1] State Key Laboratory of Rolling and Automation (Northeastern University)
基金
中国国家自然科学基金;
关键词
mathematic model; ultra fast cooling; laminar flow cooling; variable frequency control; coiling temperature control;
D O I
暂无
中图分类号
TK172 [换热设备];
学科分类号
080702 ;
摘要
A novel cooling system combining ultra fast cooling rigs with laminar cooling devices was investigated.Based on the different cooling mechanisms,a serial of mathematic models were established to describe the relationship between water flow and spraying pressure and the relationship between water spraying heat flux and layout of nozzles installed on the top and bottom cooling headers.Model parameters were validated by measured data.Heat transfer models including air convection model,heat radiation model and water cooling capacity model were detailedly introduced.In addition,effects on cooling capacity by water temperature and different valve patterns were also presented.Finally,the comparison results from UFC used or not have been provided with respect to temperature evolution and mechanical properties of Q235B steel grade with thickness of 7.8 mm.Since online application of the sophisticated CTC process control system based on these models,run-out table cooling control system has been running stably and reliably to produce resource-saving,low-cost steels with smaller grain size.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 50 条
  • [31] Strip shape modeling and its setup strategy in hot strip mill process
    Kaixiang Peng
    Hao Zhong
    Liang Zhao
    Kai Xue
    Yidao Ji
    The International Journal of Advanced Manufacturing Technology, 2014, 72 : 589 - 605
  • [32] Modelling of heat transfer in hot strip mill runout table cooling
    Timm, W
    Weinzierl, K
    Leipertz, A
    Zieger, H
    Zouhar, G
    STEEL RESEARCH, 2002, 73 (03): : 97 - 104
  • [33] Strip shape modeling and its setup strategy in hot strip mill process
    Peng, Kaixiang
    Zhong, Hao
    Zhao, Liang
    Xue, Kai
    Ji, Yidao
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2014, 72 (5-8): : 589 - 605
  • [34] Controlled Cooling of Strip Coils on the Conveyer of a Hot-Rolling Mill
    Chashchin V.V.
    Steel in Translation, 2018, 48 (6) : 388 - 392
  • [35] COOLING CHARACTERISTICS OF STEEL SHEET BY WATER FILM IN HOT STRIP MILL
    OTOMO, A
    YASUNAGA, S
    ISHIDA, R
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1987, 73 (08): : 996 - 1003
  • [36] INVESTIGATION OF STRIP COOLING ON RUNOUT ROLLER CONVEYER OF CONTINUOUS WIDE HOT-STRIP MILL
    BURDIN, VM
    GROSVALD, VG
    NIKITIN, VA
    ANTONOVA, IS
    STAL IN ENGLISH-USSR, 1967, (09): : 778 - &
  • [37] A FEEDFORWARD CONTROL-SYSTEM FOR A HOT STRIP MILL
    WAGNER, F
    MILLERSCHOEN, CW
    ECK, HL
    IRON AND STEEL ENGINEER, 1983, 60 (09): : P59 - P59
  • [38] Shape Setup System for 1700 Hot Strip Mill
    GUO Zhong-feng
    Journal of Iron and Steel Research(International), 2007, (05) : 27 - 30
  • [39] Optimal control system for hot strip finishing mill
    Okada, M
    Murayama, K
    Urano, A
    Iwasaki, Y
    Kawano, A
    Shiomi, H
    CONTROL ENGINEERING PRACTICE, 1998, 6 (08) : 1029 - 1034
  • [40] HOT STRIP MILL PROCESS CONTROL SYSTEM.
    Kubota, Sadao
    Shoji, Kazumasa
    Takahashi, Ryoichi
    Yamamoto, Akio
    Shibahara, Takashi
    Sumitomo Metals, 1986, 38 (04): : 49 - 56