Energy-Selective X-Ray Ghost Imaging

被引:0
|
作者
何雨航 [1 ,2 ]
张艾昕 [1 ,2 ]
俞文凯 [3 ]
陈黎明 [4 ]
吴令安 [1 ,2 ]
机构
[1] Institute of Physics, Chinese Academy of Sciences
[2] University of Chinese Academy of Sciences
[3] School of Physics, Beijing Institute of Technology
[4] Department of Physics and Astronomy, Shanghai Jiao Tong University
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
R814 [X线诊断学]; TP391.41 [];
学科分类号
080203 ; 1001 ; 100105 ; 100207 ; 100602 ;
摘要
X-ray ghost imaging(XGI) has opened up a new avenue for damage-free medical imaging.Here energy-selective spectroscopic XGI under poor illumination is demonstrated with a single-pixel detector for the first time.The key device was a specially fabricated Au mask incorporating a new modulation pattern design,by which means images of a real object were obtained with a spatial resolution of 10 μm and a spectral energy resolution of about 1.5 keV.Compressed sensing was also introduced to improve the image quality.Our proof-of-principle experiment extends the methodology of XGI to make possible the retrieval of spectral images with only a single-pixel detector,and paves the way for potential applications in many fields such as biology,material science and environmental sensing.
引用
收藏
页码:86 / 89
页数:4
相关论文
共 50 条
  • [21] In-situ phase analysis of large inclusions by combining computed tomography and energy-selective X-ray diffraction
    Cai, Ji-qing
    Wang, Huan
    Wang, Kun
    Qin, Ling
    Zhang, Peng-cheng
    INSIGHT, 2022, 64 (06) : 349 - 353
  • [22] What are the advantages of ghost imaging? Multiplexing for x-ray and electron imaging
    Lane, Thomas J.
    Ratner, Daniel
    OPTICS EXPRESS, 2020, 28 (05) : 5898 - 5918
  • [23] ENERGY-SELECTIVE SESD IMAGING UTILIZING A CMA
    LARSON, LA
    SORIA, F
    POPPA, H
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1980, 17 (06): : 1364 - 1366
  • [24] Energy-selective X-ray CT imaging with an EIGER2 hybrid photon counting detector in a Diondo d2 XCT system
    Martinez-Garcia, Jorge
    Gwerder, Damian
    Schiffmann, David
    Thuering, Thomas
    Jung, Dubravka Šišak
    Gkoumas, Spyridon
    Schuetz, Philipp
    e-Journal of Nondestructive Testing, 2024, 29 (03):
  • [25] X-ray ghost imaging with a specially developed beam splitter
    Zhao, Chang-Zhe
    Zhang, Hai-Peng
    Tang, Jie
    Zhao, Ni-Xi
    Li, Zhong-Liang
    Xiao, Ti-Qiao
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 : 1525 - 1533
  • [26] Energy-selective neutron transmission imaging at a pulsed source
    Kockelmann, W.
    Frei, G.
    Lehmann, E. H.
    Vontobel, P.
    Santisteban, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 578 (02): : 421 - 434
  • [27] Random-matrix bases, ghost imaging, and x-ray phase contrast computational ghost imaging
    Ceddia, David
    Paganin, David M.
    PHYSICAL REVIEW A, 2018, 97 (06)
  • [28] Improved Performance of Energy-Selective Gamma-Ray Imaging System Based on Image Restoration
    Da, Tianxing
    Zhang, Changqing
    Ma, Jiming
    Sheng, Liang
    Nie, Baojie
    Hei, Dongwei
    Li, Yang
    Duan, Baojun
    Gu, Weiguo
    Wang, Dezhong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2025, 72 (01) : 73 - 80
  • [29] Deep learning in classical x-ray ghost imaging for dose reduction
    Huang, Yiyue
    Loesel, Philipp D.
    Paganin, David M.
    Kingston, Andrew M.
    PHYSICAL REVIEW A, 2024, 110 (06)
  • [30] Megapixel X-ray ghost imaging with a binned detector in the object arm
    张海鹏
    李可
    王飞翔
    喻虹
    赵昌哲
    杜国浩
    李中亮
    邓彪
    谢红兰
    韩申生
    肖体乔
    ChineseOpticsLetters, 2022, 20 (03) : 150 - 157