Relative spectral response calibration using Ti plasma lines

被引:0
|
作者
费腾 [1 ]
潘从元 [2 ]
曾强 [1 ]
王秋平 [1 ]
杜学维 [1 ]
机构
[1] National Synchrotron Radiation Laboratory, University of Science and Technology of China
[2] College of Electrical Engineering and Automation, Anhui University
基金
中国国家自然科学基金;
关键词
branching ratio; relative spectral response calibration; titanium; laser-induced breakdown spectroscopy;
D O I
暂无
中图分类号
O53 [等离子体物理学];
学科分类号
070204 ;
摘要
This work introduces the branching ratio(BR) method for determining relative spectral responses,which are needed routinely in laser induced breakdown spectroscopy(LIBS). Neutral and singly ionized Ti lines in the 250–498 nm spectral range are investigated by measuring laser-induced micro plasma near a Ti plate and used to calculate the relative spectral response of an entire LIBS detection system. The results are compared with those of the conventional relative spectral response calibration method using a tungsten halogen lamp, and certain lines available for the BR method are selected. The study supports the common manner of using BRs to calibrate the detection system in LIBS setups.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [41] Mechanism for the disappearance of spectral lines in a nonideal plasma
    V. K. Gryaznov
    O. B. Denisov
    M. I. Kulish
    V. B. Mintsev
    N. Yu. Orlov
    V. E. Fortov
    Plasma Physics Reports, 2001, 27 : 1021 - 1024
  • [42] INTENSITY OF SPECTRAL LINES IN PLASMA IN BURNUP REGIME
    SHOLIN, GV
    KITAINER, AG
    DOKLADY AKADEMII NAUK SSSR, 1972, 203 (04): : 802 - &
  • [43] ENERGY EMITTED BY ARGON PLASMA IN SPECTRAL LINES
    YAKUBOV, IT
    OPTICS AND SPECTROSCOPY-USSR, 1965, 19 (04): : 277 - &
  • [44] ENERGY EMITTED BY THE EQUILIBRIUM PLASMA IN SPECTRAL LINES
    BIBERMAN, LM
    VOROBYOV, VS
    NORMAN, GE
    OPTIKA I SPEKTROSKOPIYA, 1963, 14 (03): : 330 - 335
  • [45] BROADENING OF HYDROGEN SPECTRAL LINES BY PLASMA ELECTRONS
    MINAEVA, AA
    SOVIET ASTRONOMY AJ USSR, 1968, 12 (03): : 459 - &
  • [46] Paracatadioptric camera calibration using lines
    Barreto, JP
    Araujo, H
    NINTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS I AND II, PROCEEDINGS, 2003, : 1359 - 1365
  • [47] Cylindrical sensor calibration using lines
    Smadja, L
    Benosman, R
    Devars, J
    ICIP: 2004 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1- 5, 2004, : 1851 - 1854
  • [48] THE MEASUREMENT OF FLAME TEMPERATURES BY THE METHOD OF THE RELATIVE INTENSITIES OF SPECTRAL LINES
    DRONOV, AP
    SVIRIDOV, AG
    SOBOLEV, NN
    OPTIKA I SPEKTROSKOPIYA, 1958, 5 (05): : 490 - 499
  • [49] Relative intensity calibration of CDS-GIS detectors on SOHO using a plasma diagnostic technique
    Landi, E
    Del Zanna, G
    Breeveld, ER
    Landini, M
    Bromage, BJI
    Pike, CD
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1999, 135 (01): : 171 - 185
  • [50] Method to validate relative spectral response curves
    Hubbs, JE
    Garcia, J
    Dereniak, EL
    INFRARED DETECTORS AND FOCAL PLANE ARRAYS V, 1998, 3379 : 510 - 519