Study of Plasma MHD Equilibrium in HL-2A Tokamak

被引:0
|
作者
何宏达 [1 ]
张锦华 [1 ]
董家齐 [1 ]
李强 [1 ]
机构
[1] Southwestern Institute of Physics,Chengdu 610041,China
基金
中国国家自然科学基金;
关键词
simulations; equilibrium; HL-2A tokamak;
D O I
暂无
中图分类号
O53 [等离子体物理学];
学科分类号
070204 ;
摘要
EFIT(Equilibrium Fitting) code is successfully transplanted for HL-2A tokamak pa-rameters.The evolution of the equilibrium configurations for shot 2898 is simulated.It is shownthat the discharge starts with a limiter configuration and develops into a divertor configurationgradually after t=200 ms.The latter lasts until the end of the discharge at t=900 ms.Theevolution of the major plasma shape parameters such as the boundary magnetic fluxes,the posi-tions of the x-point and magnetic axis,and the minor radii obtained are calculated and comparedwith the experimental results.The agreement between the simulation and experiments are shownto be reasonable.The possibility for discharge quality improvement is discussed.
引用
收藏
页码:397 / 401
页数:5
相关论文
共 50 条
  • [31] Impurity Measurement and Study on HL-2A Divertor Tokamak
    崔正英
    孙平
    潘宇东
    李伟
    王全明
    段旭如
    Plasma Science and Technology, 2006, (01) : 61 - 64
  • [32] Study on edge localized mode during plasma vertical swing in HL-2A tokamak
    Wu, N.
    Chen, S. Y.
    Mou, M. L.
    Tang, C. J.
    Song, X. M.
    Yang, Z. C.
    Yu, D. L.
    Xu, J. Q.
    Jiang, M.
    Ji, X. Q.
    Wang, S.
    Li, B.
    Liu, L.
    PHYSICS OF PLASMAS, 2018, 25 (10)
  • [33] A pellet injector of the HL-2A tokamak
    I. V. Vinyar
    A. Ya. Lukin
    S. V. Skoblikov
    P. V. Reznichenko
    Instruments and Experimental Techniques, 2013, 56 : 607 - 612
  • [34] A pellet injector of the HL-2A tokamak
    Vinyar, I. V.
    Lukin, A. Ya.
    Skoblikov, S. V.
    Reznichenko, P. V.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2013, 56 (05) : 607 - 612
  • [35] Vacuum system for HL-2A tokamak
    Zeng, C
    Cui, CH
    Liu, LD
    Xiao, C
    Gao, XY
    PLASMA SCIENCE & TECHNOLOGY, 2005, 7 (01) : 2632 - 2636
  • [36] Experiment study of edge localized mode with plasma vertical jogging in HL-2A tokamak
    Wu, N.
    Chen, S. Y.
    Song, X. M.
    Mou, M. L.
    Huang, J.
    Wang, Z. T.
    Tang, C. J.
    Song, X.
    Xia, F.
    Jiang, M.
    PHYSICS OF PLASMAS, 2017, 24 (09)
  • [37] MHD instability fluctuation measurement on the HL-2A tokamak by using the HCN laser interferometer
    Li, Y. G.
    Zhou, Y.
    Deng, Z. C.
    Yi, J.
    Li, Y.
    Wang, H. X.
    Ji, X. Q.
    Deng, W.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (08) : 1270 - 1272
  • [38] Vacuum System for HL-2A Tokamak
    曹曾
    崔成和
    刘德权
    蔡萧
    高霄燕
    Plasma Science & Technology, 2005, (01) : 2632 - 2636
  • [39] MHD instability fluctuation measurement on the HL-2A tokamak by using the HCN laser interferometer
    Y. G. Li
    Y. Zhou
    Z. C. Deng
    J. Yi
    Y. Li
    H. X. Wang
    X. Q. Ji
    W. Deng
    Journal of the Korean Physical Society, 2014, 65 : 1270 - 1272
  • [40] Development of ECE/ECEI diagnostics and MHD-related studies on HL-2A tokamak
    Yang, Z. C.
    Jiang, M.
    Shi, Z. B.
    Ding, X. T.
    Luhmann, N. C., Jr.
    Zhong, W. L.
    Chen, W.
    Shi, P. W.
    Xu, Y.
    Wen, J.
    Liang, A. S.
    Liu, Y.
    Yang, Q. W.
    20TH JOINT WORKSHOP ON ELECTRON CYCLOTRON EMISSION AND ELECTRON CYCLOTRON RESONANCE HEATING (EC20), 2019, 203