Progress in research and application of water mist fire suppression technology

被引:0
|
作者
LIU Jianghong
机构
关键词
water mist; fire suppression technology; application;
D O I
暂无
中图分类号
X932 [爆炸安全与防火、防爆];
学科分类号
0837 ;
摘要
Water mist technology in fire suppression has been a subject of many investigations over the last decade. This paper introduces the concept of water mist technology and discusses its extinguishment mechanisms in comparison with other fire suppression systems briefly. A survey is made on the recent applications of water mist for (1) Class B spray and pool fires in machinery spaces, gas turbine enclosures, combat vehicles, and flammable liquid storage rooms; (2) Class A fires in residential occupancies, marine accommoda-tions and public spaces, heritage buildings and libraries; (3) Class C fires in electronic equipment and computer rooms; and (4) the fires in aircraft onboard cabin and cargo com-partments. The paper proceeds to review some new applica-tions of water mist for the Class K fires in commercial cook rooms. Use of water mist for total-ship protection as well as the fire protection of heavy goods vehicle shuttle trains is also investigated. At last, the up-to-date development of corresponding test to evaluate the capabilities and limitaions of water mist is discussed.
引用
收藏
页码:718 / 725
页数:8
相关论文
共 50 条
  • [31] Experiment on Water Mist Fire Suppression in Long and Narrow Spaces
    Liu Jianghong
    Zhu Wei
    Liao Guangxuan
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL. VIII, PTS A AND B, 2010, 8 : 798 - 806
  • [32] On water mist fire suppression mechanisms in a gaseous diffusion flame
    Ndubizu, CC
    Ananth, R
    Tatem, PA
    Motevalli, V
    [J]. FIRE SAFETY JOURNAL, 1998, 31 (03) : 253 - 276
  • [33] A zone model in simulating water mist suppression on obstructed fire
    Li, Y. F.
    Chow, W. K.
    [J]. HEAT TRANSFER ENGINEERING, 2006, 27 (10) : 99 - 115
  • [34] Experiment of heat release rate of pool fire effect on water mist fire suppression
    School of Astronautics, Beijing University of Aeronautics and Astronautics, Beijing 100083, China
    [J]. Beijing Hangkong Hangtian Daxue Xuebao, 2008, 5 (537-540):
  • [35] Experimental and Numerical Study of Water Mist Fire Suppression System Effectiveness on Shielded Fire
    Kuswantoro
    Nugroho, Y. S.
    [J]. 3RD INTERNATIONAL TROPICAL RENEWABLE ENERGY CONFERENCE SUSTAINABLE DEVELOPMENT OF TROPICAL RENEWABLE ENERGY (I-TREC 2018), 2018, 67
  • [36] THE DOUBLE-DIFFUSIVE CONVECTION IN THE PROCESS OF WATER MIST FIRE SUPPRESSION
    Xu, Kai
    Lu, Wen-Qiang
    [J]. HT2008: PROCEEDING OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, VOL 3, 2009, : 51 - 56
  • [37] Extinguishment of cooking oil fires by water mist fire suppression systems
    Liu, ZG
    Kim, AK
    Carpenter, D
    Kanabus-Kaminska, JM
    [J]. FIRE TECHNOLOGY, 2004, 40 (04) : 309 - 333
  • [38] An experimental and numerical study on fire suppression using a water mist in an enclosure
    Kim, SC
    Ryou, HS
    [J]. BUILDING AND ENVIRONMENT, 2003, 38 (11) : 1309 - 1316
  • [39] Experimental and numerical study on water mist suppression system on room fire
    Yang, Peizhong
    Liu, Tao
    Qin, Xian
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (10) : 2309 - 2316
  • [40] An experimental study of the effects of water mist characteristics on pool fire suppression
    Gupta, Meenakshi
    Pasi, Amit
    Ray, Anjan
    Kale, S. R.