The Knee Joint Design and Control of Above-knee Intelligent Bionic Leg Based on Magneto-rheological Damper

被引:7
|
作者
Hua-Long Xie 1 Ze-Zhong Liang 1 Fei Li 2 Li-Xin Guo 1 1 School of Mechanical Engineering and Automation
机构
基金
中国博士后科学基金;
关键词
Knee joint; above-knee intelligent bionic leg; magneto-rheological damper;
D O I
暂无
中图分类号
R318.0 [一般性问题];
学科分类号
摘要
The above-knee intelligent bionic leg is very helpful to amputees in the area of rehabilitation medicine. This paper first introduces the functional demand of the above-knee prosthesis design. Then, the advantages of the four-bar link mechanism and the magneto-rheological (MR) damper are analyzed in detail. The fixed position of the MR damper is optimized and a virtual prototype of knee joint is given. In the end, the system model of kinematics, dynamics, and controller are given and a control experiment is performed. The control experiment indicates that the intelligent bionic leg with multi-axis knee is able to realize gait tracking of the amputee s healthy leg based on semi-active control of the MR damper.
引用
收藏
页码:277 / 282
页数:6
相关论文
共 50 条
  • [31] A general inverse control model of a magneto-rheological damper based on neural network
    Yan, Yaya
    Dong, Longlei
    Han, Yi
    Li, Weishuo
    JOURNAL OF VIBRATION AND CONTROL, 2022, 28 (7-8) : 952 - 963
  • [32] Control of Compliant Joint Based on Magneto-rheological Fluid Coupling Transmission
    Wei, Wei
    Cai, Shibo
    Bian, Guibin
    Bao, Guanjun
    Yu, Jianjun
    Yang, Dongling
    Zhang, Libin
    2019 IEEE 4TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM 2019), 2019, : 18 - 23
  • [33] Design of a magneto-rheological gun recoil damper based on Herschel-Bulkley model
    Hou, Bao-Lin
    Zhao, Cheng-Zhang
    Dandao Xuebao/Journal of Ballistics, 2006, 18 (02): : 44 - 48
  • [34] Risk factor analysis for above-knee amputation in patients with periprosthetic joint infection of the knee: a case-control study
    Franziska Eckers
    Christoph J. Laux
    Sebastian Schaller
    Martin Berli
    Yvonne Achermann
    Sandro F. Fucentese
    BMC Musculoskeletal Disorders, 22
  • [35] Fuzzy PID control for sit-and-reach trainer based on magneto-rheological damper
    He, Wei
    Li, Hao
    Ma, Tingting
    Zhao, Yibo
    Zhao, Xinyan
    Song, Quanjun
    2024 3RD INTERNATIONAL CONFERENCE ON ENERGY AND POWER ENGINEERING, CONTROL ENGINEERING, EPECE 2024, 2024, : 201 - 205
  • [36] Risk factor analysis for above-knee amputation in patients with periprosthetic joint infection of the knee: a case-control study
    Eckers, Franziska
    Laux, Christoph J.
    Schaller, Sebastian
    Berli, Martin
    Achermann, Yvonne
    Fucentese, Sandro F.
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [37] Research on Semi-Active Vibration Control of Pipeline Based on Magneto-Rheological Damper
    Ji, Hui
    Huang, Yeqing
    Nie, Songlin
    Yin, Fanglong
    Dai, Zhaoyi
    APPLIED SCIENCES-BASEL, 2020, 10 (07):
  • [38] Unbalance response control of rotor by magneto-rheological fluid based squeeze film damper
    Kim, Keun-Joo
    Lee, Chong-Won
    Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, Vol 1, Pts A-C, 2005, : 1053 - 1060
  • [39] Design optimization and experimental characterization of a rotary magneto-rheological fluid damper to control torsional vibration
    Abouobaia, Ehab
    Sedaghati, Ramin
    Bhat, Rama
    SMART MATERIALS AND STRUCTURES, 2020, 29 (04)
  • [40] Low-force magneto-rheological damper design for small-scale structural control
    Winter, Benjamin D.
    Swartz, R. Andrew
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (11):