Pocket formula for mass attenuation coefficient, effective atomic number, and electron density of human tissues

被引:0
|
作者
H.C.Manjunatha [1 ]
L.Seenappa [1 ]
机构
[1] Department of Physics, Government College for Women
关键词
Effective atomic number; Mass attenuation coefficient; Tissues;
D O I
暂无
中图分类号
R817 [放射性同位素在医学上的应用];
学科分类号
1001 ; 100105 ; 100207 ; 100602 ;
摘要
We have proposed a pocket formula for mass attenuation coefficient(μ/ρ), mass energy absorption coefficient(μ/ρ), and effective atomic number(Z) in different tissues of human organs. We have also assigned a new chemical formula for all studied tissues based on their composition. We have introduced a new parameter called effective composition index(C). Based on this, we have introduced a new method to compute the effective atomic number. The evaluated photon interaction parameters are graphically represented. The evaluated average, maximum,minimum, and standard deviations of effective atomic number are tabulated. The proposed formula produces a mass attenuation coefficient, mass energy absorption coefficient, and effective atomic number from their composition
引用
收藏
页码:54 / 61
页数:8
相关论文
共 50 条
  • [1] Pocket formula for mass attenuation coefficient, effective atomic number, and electron density of human tissues
    Manjunatha, H. C.
    Seenappa, L.
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (03)
  • [2] Pocket formula for mass attenuation coefficient, effective atomic number, and electron density of human tissues
    H. C. Manjunatha
    L. Seenappa
    [J]. Nuclear Science and Techniques, 2019, 30
  • [3] Determination of mass attenuation coefficient, effective atomic number and effective electron density for tungsten alloys
    [J]. Elmahroug, Y. (youssef_phy@hotmail.fr), 1600, Inderscience Enterprises Ltd., 29, route de Pre-Bois, Case Postale 856, CH-1215 Geneva 15, CH-1215, Switzerland (08):
  • [4] Studies on mass attenuation coefficient, effective atomic number and electron density of some vitamins
    D. Demir
    A. Turşucu
    T. Öznülüer
    [J]. Radiation and Environmental Biophysics, 2012, 51 : 469 - 475
  • [5] Studies on mass attenuation coefficient, effective atomic number and electron density of some vitamins
    Demir, D.
    Tursucu, A.
    Oznuluer, T.
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2012, 51 (04) : 469 - 475
  • [6] Measurements of mass attenuation coefficient, effective atomic number and electron density of some amino acids
    Kore, Prashant S.
    Pawar, Pravina P.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 98 : 86 - 91
  • [7] Studies on mass attenuation coefficient, effective atomic number and electron density of some thermoluminescent dosimetric compounds
    Onder, P.
    Tursucu, A.
    Demir, D.
    Gurol, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 292 : 1 - 10
  • [8] Variation of mass attenuation coefficient, effective atomic number, and electron density with incident photon energy of some organic acids
    Singh, Tejbir
    Kaur, Paramjeet
    Singh, Parjit S.
    [J]. NUCLEAR SCIENCE AND ENGINEERING, 2007, 156 (02) : 229 - 243
  • [9] The Direct-Zeff software for direct calculation of mass attenuation coefficient, effective atomic number and effective electron number
    Un, Adem
    Caner, Tanfer
    [J]. ANNALS OF NUCLEAR ENERGY, 2014, 65 : 158 - 165
  • [10] Accurate measurement of effective atomic number and electron density with X-ray attenuation coefficient spectrum
    Sakurai, H.
    Hoshi, K.
    Morimoto, I.
    Shiroto, Y.
    Ishizaki, K.
    Suzuki, K.
    Hasebe, Y.
    Ohno, Y.
    Torikoshi, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2023, 542 : 234 - 241